![](/html/1c/1c5b/1c5bc5fd9667730c7315bb540903b7456d9f65ecc511886a2060cd9ffd971a56/bg1.png)
OPERATING
INSTRUCTIONS
High-Speed Contact Griller
TX Series
TABLE OF CONTENTS PAGE
Installation / Set-Up ..................................................... 2
Overlay Glossary .......................................................... 2
Operation & Programming ........................................ 2-3
Maintenance ................................................................. 4
Cleaning ........................................................................ 4
Diagnostic Troubleshooting ......................................... 5
Troubleshooting ............................................................ 5
Exploded View & Parts List ..................................... 6-7
Wiring Diagram ............................................................. 8
LIMITED WARRANTY
This product is warranted to be free from defects in
material and/or workmanship for a period of two (2)
years from date of original installation, not to exceed 30 months from date of shipment from our
factory. On location service will be covered for
a period of (1) one year from date of original
installation. Customer must provide proof of
purchase. (Travel charges are limited to 2 hours
travel time, 100 miles round trip. One trip per
repair) After one year the customer is responsible
for all trip charges, mileage, etc.
PRODUCT SPECIFICATION
Electrical
208 Volt 60 Hz. Single Phase
19.2 Amps 4000 Watts Max.
240 Volt 60 Hz. Single Phase
22.2 Amps 5325 Watts Max.
355 East Kehoe Blvd. l Carol Stream, IL 60188
Printed in 2000
Prince Castle Inc.
Tel: (630) 462-8800
Any component which proves to be faulty in material
and/or workmanship will be replaced or repaired (at
the option of Prince Castle, Inc.) without cost to the
customer for parts or labor.
This warranty is subject to the following exceptions/
conditions:
l Any use of non genuine Prince Castle spare
parts voids this warranty. All service should be
performed by an Authorized Prince Castle Sevice
Agency, failure to do so will void this warranty.
l Damage caused by carelessness, neglect, and/
or abuse (e.g., dropping, tampering or altering
parts), equipment damaged in shipment, by fire,
flood or an act of God is not covered under this
warranty.
l Fax: (630) 462-1460
Toll Free: 1-800-PCASTLE
537-504
![](/html/1c/1c5b/1c5bc5fd9667730c7315bb540903b7456d9f65ecc511886a2060cd9ffd971a56/bg2.png)
INSTALLATION
1. After you have removed the toaster from the
carton, inspect the unit for signs of damage. If there
is damage to the unit:
l Notify carrier within 24 hours after delivery.
l Save carton and packing materials for inspection
purposes.
l Contact the Prince Castle Customer Sales
Department at 1-630-462-8800 to arrange for
a replacement to be sent.
l Remove protective coating.
OPERATION
1. Press On/Off Button, conveyor will begin to turn
and the display will read LO.
PROG
L O
ACT
SET
2. Verify that all parts have been received.
3. Locate toaster on a flat surface
4. Plug unit into the proper voltage receptacle.
OVERLAY GLOSSARY
ON/OFF Button: Turns Unit on and off.
SCAN UP/ACTUAL TEMP Button: When
pressed in run mode, display will show actual
platen temperature. In programming mode,
when pressed, will increase set point temperature.
2. Once the toaster reaches its Set Point temperature
the display will read R D Y and the ACT LED will
be lit.
PROG
R D Y
ACT
SET
NOTE: When the toaster is turned OFF, if the platen is
above 450°F, the display will alternately indicate COOL and OFF and the conveyor belt
motor will continue to run for up to 45 minutes
to protect the belt. When cooled sufficiently,
the display will go blank and the conveyor belt
motor will turn off.
SCAN DOWN Button: In programming mode,
when pressed will decrease the set point
temperature.
SET BUTTON: In run mode when pressed will
display the Set Point Temperature. In program
mode, when pressed, will store a new Set Point
Temperature.
PROG
COOL
ACT
SET
PROG
O F F
ACT
SET
2
![](/html/1c/1c5b/1c5bc5fd9667730c7315bb540903b7456d9f65ecc511886a2060cd9ffd971a56/bg3.png)
VIEW ACTUAL TEMPERATURE
1. When the toaster is at the proper operating temperature, the display will always show RDY. To
view the actual temperature, press and release
either the UP ARROW or DOWN ARROW. The
display will show the actual platen temperature for
5 seconds, then switch back to RDY.
2. Use the UP or DOWN buttons to adjust to the
desired setting. Press and release the SET button
to save the new setting and return to the operation
mode.
PROG
5 0 0
ACT
SET
PROG
RDY
ACT
SET
PROG
RDY PROG
ACT
SET
500
ACT
SET
PROG
RDY
VIEW SET POINT TEMPERATURE
1. To view the Set Point Temperature, press and
release the SET Button. The LED next to the
ACT goes off and the LED next to SET comes
on, and the set point temperature will be displayed
for 5 seconds, then the display will change back to
RDY.
PROG
RDY
ACT
SET
PROG
500
ACT
SET
PROG
RDY
ACT
SET
FAHRENHEIT AND CELSIUS SETTINGS
1. To switch the unit from Fahrenheit to Celsius,
press and hold the DOWN ARROW once you
release it the unit will switch to Celsius. To switch
from Celsius to Fahrenheit press and holdand
release the UP ARROW when you turn the unit
on.
BUN CRUSH SETTINGS
1. The toaster is designed to adjust for different cuts
of buns. The bun crush adjustment knobs are
located on both sides of the toaster. Right side
ACT
SET
adjustment is for HEELS, and left side adjustment
is for CROWNS.
PROGRAMMING SET POINT TEMPERATURE
1. To change the set point temperature, press and
hold the SET button for 6 seconds. The LEDs
next to SET and PROG will flash and the current
set point temperature will be displayed.
PROG
5 0 5
ACT
SET
1=Thinnest Cut Crowns A=Thinnest Cut Heels
6=Thickest Cut Crowns F=Thickest Cut Heels
3