OPERATING
INSTRUCTIONS
Single Function Timers
Model No. 740-T, 740-TJ &
740-TF Series
Model 740-T8
Prince Castle’s second generation of Merlin Timers
feature a new slim design which gives you mounting
flexibility. The 740 Series Timers are designed so
each channel can be programmed independently,
and used simultaneously. The timers are simple to
program and simple to use. The push of a button
activates each channel, and a alarm and multicolored flashing channel buttons alert the operator
when timing is complete.
ELECTRICAL
740-TSeries 740-TJ Series
120 Volts 100 Volts
50-60 Hz 50/60 Hz
TABLE OF CONTENTS PAGE
Installation..................................................................... 2
Programming................................................................. 2
Operation ....................................................................... 3
Cleaning ........................................................................ 4
Parts List....................................................................... 4
Exploded View .............................................................. 5
Troubleshooting ............................................................ 5
Wiring Diagrams ........................................................... 6
LIMITED WARRANTY
This product is warranted to be free from defects in material
and/or workmanship for a period of 1 year from date of original
installation, not to exceed 18 months from the date of
manufacture.
Any component which proves to be faulty in material and/or
workmanship will be replaced or repaired (at the option of
Prince Castle, Inc.) without cost to the customer for parts and
labor. This equipment is portable; charges for on-location
service (e.g., trip charges, mileage) are not included in the
provisions of this warranty.
This warranty is subject to the following exceptions/conditions:
• Use of any non-genuine Prince Castle parts voids this
warranty.
• All labor to be performed during regular work hours.
Overtime premium (the incremental amount) will be charged
to the customer.
• Damage caused by carelessness, neglect and/or abuse
(e.g., dropping, tampering or altering parts, equipment
damaged in shipment, by fire, flood or an act of God) is not
covered under this warranty.
• All problems due to operation at voltages other than that
specified on equipment nameplates are not covered by this
warranty. Conversion to correct voltage is the customer’s
responsibility.
• This equipment must be serviced by Prince Castle
Authorized Service Agency or a Prince Castle Service
Technician during the warranty period.
740-TF Series
220-240 Volts
50/60 Hz
740-517revB
355 East Kehoe Blvd. ! Carol Stream, IL 60188
Tel: (630) 462-8800 ! Fax: (630) 462-1460
Toll Free: 1-800-PCASTLE
Printed in USA 3/06 © 2006

INSTALLATION
1. After you have removed the timer from the carton,
inspect the unit for signs of damage. If there is
damage to the unit:
! Notify carrier within 24 hours after delivery.
! Save carton and packing materials for inspection
purposes.
! Contact your local Prince Castle dealer or, if
purchased directly, the Prince Castle Customer
Sales Department at 1-630-462-8800 to arrange
for a replacement to be sent.
2. Verify that all parts have been received. Mounting
brackets and hardware are provided.
SCAN/UP
ARROW
SCAN/DOWN
ARROW
PRINCE
CASTLE
Logo
In the program mode, it increases time
values for each channel . In the Run
Mode, it is used in conjunction with logo
button to increase the volume.
In the program mode, it decreases time
values for each channel . In the run
mode, it is used in conjunction with logo
button to decrease the volume.
Activates Program Mode and used to
adjust the alarm sound level.
PROGRAMMING
3. To mount the timer, place mounting brackets in desired location. Scribe location of mounting holes,
center punch, and drill holes. Attach timer to mounting brackets placing star washer between bracket and
timer.
DISPLAYS AND INDICATORS
TIME
Display
CHANNEL
Display
H:M
M:S
LED
Indicators
Shows the time for the selected channel
number.
Shows the channel number selected
and in use. (The 740-T2 model does
not have this display.)
Indicates the time value is in Hours and
Minutes.
Indicates that the time value is in
Minutes and Seconds.
Located above each channel timer
button, these lights change color
depending on the stage of the countdown. Green = first 70% of countdown,
Yellow = next 20% countdown,
Red = last 10% of countdown.
1. To program, press and hold the PRINCE CASTLE
logo for six seconds. The TIME display changes
from ---- to Prog, and a beep will sound.
See figure 1.
figure 1
P r o g
2. Select and press the timer channel to be programmed. The LED indicator for the selected
button will turn yellow and a beep will sound. The
selected channel number will be displayed in the
CHANNEL display, the current programmed time
for that channel will be displayed in the TIME
display, and the time value will indicate either H:M
OR M:S. See figure 2.
figure 2
1
8:00
CONTROLS
The 740-T2 has 2 channels, the 740-T4
Channel
(Timer)
Printed in USA 3/06 © 2006
has 4 channels, the 740-T8 has 8
channels and the 740-T12 has 12
channels.
3. To change the program time for the selected
channel, use the SCAN/UP Arrow or the SCAN/
DOWN Arrow button.
2
740-517revB