This product (with the exception of the water tube, part no. 625-197S) is
warranted to be free from defects in material and/or workmanship for a
period of two (2) years from date of original installation, not to exceed
30 months from date of shipment from our factory. P.C. Boards and Heater
Assemblies are warranted for three (3) years from date of installation, not
to exceed 42 months from date of shipment. Any component which proves
to be faulty in material and/or workmanship will be replaced or repaired (at
the option of Prince Castle, Inc.) without cost to the customer for parts or
labor. This warranty covers on location service (i.e. trip charges and/or
mileage). Travel mileage is limited to 100 miles (200 kilometers) round trip
(one trip warranty) from an authorized service agency or its sub-service
agency.
This warranty is subject to the following exceptions/conditions:
• Use of any non-genuine Prince Castle parts voids this warranty.
• All labor shall be performed during regular work hours. Overtime
premium will be charged to the buyer.
• Damage caused by carelessness, neglect, and/or abuse (e.g.,
dropping, tampering or altering parts, equipment damaged in shipment,
by fire, flood or an act of God) is not covered under this warranty.
Indicates information important to the proper operation of the
unit. Failure to observe may result in damage to the
equipment and/or severe bodily injury or death.
CAUTION
Indicates information important to the operation of the unit. Failure
to observe may result in damage to the equipment.
Installation
Remove the unit from the carton and inspect for signs of damage. If there
is damage to the unit:
• notify the carrier within 24 hours of delivery
• save carton and packaging materials for inspection purposes
• contact your local dealer, or if purchased directly, the Prince Castle
Sales Department at 800-722-7853 or 1-630-462-8800 to arrange for a
replacement unit.
WATER CONNECTION REQUIREMENTS
If this is a new installation, accessory - 625-104 Regulatory Assembly Kit
is required for the 625-MCD. The 625-MFY comes with the 625-253S
Regulator Assembly. Always use area codes for determination.
Important
Prince Castle reserves the right to change specifications and
product design without notice. Such revisions do not entitle the
buyer to corresponding changes, improvements, additions or
replacements for previously purchased equipment.
NOTE: When installing this unit, the ambient temperature at the mounting
site should not exceed 37.8°C (100°F).
CAUTION
All electrical connections must be in accordance with local electrical codes
and any other applicable codes.
Plug the unit into an applicable electrical receptacle. Connect the water
line to the back of the unit.
CAUTION
Water connection must provide maximum water pressure of 20 – 30 psi
(138 – 207 kPa).
A. Turn unit power On/Off switch to ON position. The display
1
flashes all segments for 3 seconds. Then display will show
PRINCE CASTLE for seven seconds.
B. After ten seconds the display will show PRE-HEAT.
NOTE: The next-to-left most decimal point appears indicating
power is applied to the platen. Platen will heat to the setpoint
temperature.
Place the spatula fully into the unit and press the ST AR T b utton. A
3
beep will sound and the display will start to count down the steam
cycle. (The countdown will round down to the nearest second, e.g.
11.5 seconds will appear as 11 seconds in the display.)
Operation
2
4
A. When the unit reaches the setpoint temperature, display will
show the product name assigned to button 1.
B. If 1 is the desired product to be steamed, pull out the spatula
and place the product onto the spatula, cut side down.
Or press product buttons 2, 3 or 4, then place product on the
spatula, cut side down.
When steam cycle is complete, the unit will sound a tone and the
display will flash REMOVE.
Pull out the spatula and remove the finished product.
A. Press and hold the TEMPERATURE button. The display will
1
show the current temperature setting for Celsius (C) or
Fahrenheit (F).
B. While holding the TEMPERATURE button, press the C/F
button to change the setting between Fahrenheit and Celsius.
C. Release the TEMPERATURE button to store the new value.
A. Press the UP or DOWN Arrow button until the temperature
3
readout matches the calibration reading.
B. Press the RAPID STEAMER LOGO button to store the desired
calibration and exit CAL TEMP Mode.
NOTE: Pressing the PRODUCT 3 button at any time exits the
Program Mode without storing the change.
The CAL TEMP Mode is used to calibrate the platen temperature
2
with an external meter connected to the meter plug inlet on the
bottom right side of the unit. Add ± 5°C (± 10°F).
A. Press and hold RAPID STEAMER LOGO button and immediately
press and hold the TEMPERATURE button. Hold for 6 seconds.
B. The display now shows the current calibration temperature.
C. Press the PRODUCT 2 button to zero any previous calibration offset
value. The display will now show the platen temperature without any
calibration offset.
Factory Presets
Loading factory presets restores the unit to factory settings and voids
all user programmed information.
A. During power up, press and hold both PRODUCT 1 and
PRODUCT 4 buttons within 3 seconds. The display will flash
PRESETS LOADED.
B. Release both buttons.
625-MCD
Default Factory Presets:
ON OFF CyclesDelay
1.5 3.022.5
625-MFY
Default Factory Presets:
ON OFF CyclesDelay
0.5 162.5
View Firmware Version
Press and hold the RAPID STEAMER LOGO button first, then press
and hold the ST AR T button. The display will show the current firmware
version.
Programming Product Name and Water Cycle (continued)
Steamer
A. Press the UP or DOWN Arrow button to change the valve
8
OFF time.
B. Press the RAPID STEAMER LOGO button to store the new
valve OFF time.
NOTE: Pressing the PRODUCT 3 button at any time exits the
Program Mode without storing the change.
A. Press the UP or DOWN Arrow button to change the number
10
of water cycles.
B. Press the RAPID STEAMER LOGO button to store the new
water cycle number.
NOTE: Pressing the PRODUCT 3 button at any time exits the
Program Mode without storing the change.
The display now shows the product’s number of on-off water
9
valve cycles.
The display now shows the current product set temperature.
11
Platen temperature can be set between 265° – 350°F
12
(129° – 176°C).
A. Press the UP or DOWN Arrow button to scroll to the desired
temperature.
B. Press the RAPID STEAMER LOGO button to store the desired
temperature.
NOTE: Pressing the PRODUCT 3 button at any time exits the
Program Mode without storing the change.
Factory Pre-Set Temperatures
625-MCD Factory pre-set temperatures:
Filet: 305°F (151°C)
Large: 305°F (151°C)
PROD1 – 12: 305°F (151°C)
625-MFY Factory pre-set temperatures:
Filet: 350°F (176°C)
Large: 350°F (176°C)
PROD1 – 12: 350°F (176°C)
The display now shows the time delay between when the
13
product is finished and when the alarm sounds.
The delay can be set for 0.0 to 10.0 seconds.
A. Press the UP or DOWN Arrow button to scroll to the desired
time delay.
B. Press the RAPID STEAMER LOGO button to store the
desired time and to exit the Program Mode.
NOTE: Pressing the PRODUCT 3 button at any time exits the
Program Mode without storing the change.
Turn the unit off and unplug the power cord from the electrical
receptacle. Proceed with caution, unit is still hot!
CAUTION
This unit is not watertight. Do not clean with a water jet/jet spray. Do not
immerse the unit in water.
Do not use abrasive materials such as scrapers, steel wool, etc. to clean
the spatula or steam chamber.
While wearing protective gloves, remove the top cover by pulling
1
up and off the unit.
Top C over
A. Wash top cover, top plate, and venturi plate in a solution of
3
®
APSC / APC made up in the back sink.
McD
B. Rinse with clean water, and then sanitize in a solution of
®
McD
C. Let air dry.
Sink Pak Sanitizer.
The following equipment is required:
®
•McD
All Purpose Super Concentrate (APSC)
®
•McD
Sink Pak Sanitizer McD® APC (Australia only)
®
Delimer™ (as required)
•McD
• Clean sanitized towel
• Protective (insulated) gloves
While wearing protective gloves:
2
A. Remove spatula.
B. Remove the top plate
by carefully sliding it
forw ard and out of the
unit.
C. Remove the venturi
plate.
Wipe the steam chamber surface with a clean sanitized cloth.
4
OPTIONAL: If the surface shows
signs of excessive calcium and
lime buildup, dissolve two
teaspoons of McD
a small coffee cup with 100 mI of
water. Pour half on each side.
Allow to sit for 5 minutes. Using a
clean sanitized towel, thoroughly
rinse and wipe the internal
surfaces of the steam chamber.
®
Delimer™ in
Top Plate
Venturi Plate
Spatula
Use brushes to clean the water tube. Dip the brush in warm water
5
or deliming solution. Insert the brush about 1" into water tube and
then remove. Repeat for 30 seconds.
Insert brush here.
Wash all external surfaces of the steamer with a solution of
6
®
APSC / APC. Using the McD® APSC / APC spray bottle,
McD
spray directly onto a clean sanitized towel and wipe the unit clean.
CAUTION
Do not spray directly on the unit or use abrasive cleaners!
Reassemble unit.
Turn the unit on. When unit is preheated, run a minimum of four
cycles to prime the unit and remove any residual cleaner.
It is recommended that the steamers go through a deliming
procedure at least once a month. Some hard water areas may
require daily, weekly, or biweekly deliming based upon actual
buildup.