Primus FS16, 40, FS55, FS23, FS33 Service Instruction

...
Page 1
www.groupdynamics-laundry.com sales@groupdynamics.lv
SSSService
ervice iiiinstruction
ervice ervice
nstruction
nstructionnstruction
Code/RefNr.:
Date: 18 Sep 2008
Subject:
WARNING:
Carry out the handling according to the following manufacturers
instructions.
Always respect warnings from the relevant manuals of the machine.
Make sure all electric power or other energy sources are disconnected
and closed before any servicing. Always switch off the main switch.
Wait 10 minutes after electrical power is disconnected to eliminate power
on the inverter terminals.
Installation, maintenance and service must be executed by skilled service
personnel only or by a service organisation with appropriate authorization from the manufacturer.
For service, use only original replacement parts.
Re-install all machine parts in the original way.
The qualified agency performing this work assumes all responsibility for
this kit installation. Other service activities than described below, disable all manufacturers responsibility.
Make sure children are not around during work in progress.
525927 / 525928
Install an AC-reactor on FS16/23/33/40/55, RS27/35
Suitable for all versions except FS40/55 3x200-240V
Primus Belgium
Driemasten 126
B-8560 Gullegem
Phone: +32 (0)56 43 52 00 Fax: +32 (0)56 40 34 63
E-mail: aftersales@primuslaundry.com
Web: www.primuslaundry.com
Belgium
Primus Central Europe
Czech Republic
Phone:+420 556 768 800 Fax: +420 556 723 383
E-mail: sales@primuslaundry.cz
Web: www.primuslaundry.com
Mistecká 1116 742 58, Příbor
Primus France
Rue Jacques Monod z.i. Est
F-69120 Vaulx-en-Velin
Phone:+33 (0)4 78 79 55 75 Fax: +33 (0)4 72 04 62 72
E-mail: info@primuslaundry.fr
Web: www.primuslaundry.com
France
Page 2
Air filter
Air fan
Air filter
Air fan
www.groupdynamics-laundry.com sales@groupdynamics.lv
Washer Dryer Ironer
PW5 P6, P7 C6, 8 RS6, 7, 10 RS13, (16), 18, 22, 27, 35 FS6, 7, 10 FS16, 22 FS33, 40, 55 FS120 MB16, 26, 33 MB44, 66 MB90, 140, 180
Washer Dryer Ironer
General Chasis Shock absorbers Cabinet Controler Coin unit Electric components & sensors Heating unit Inlet Soap hopper Motor & pulley & belts
Bearing house & seals Drum Door Drain
Applicable machine models
DAM5 / DAMC5 DA9 / DAM(S)(T)9 T9 T11, 13, 16 T1313 T24, 35 DA11, 13, 15 DA1313 D25, 35 D55, 77
Pony I18, 25, 30 I35, 50 IF50 / IR50 IFF Crossfolder Stacker
Applicable type of spare parts
General Chasis Cabinet Controler Coin unit Electric components & sensors Heating unit Motor & pulley & belts Bearing house & seals Drum Door
Exhaust
General Chasis Cabinet Controler Coin unit Electric components & sensors Heating unit Inlet Motor & pulley & chains Bearing house Ironer belts
Exhaust Delivery system Folding system
525928 Instruction AC-reactor FS16-55 RS27-35 P2/15
Page 3
www.groupdynamics-laundry.com sales@groupdynamics.lv
1) Subject:
Install an AC-reactor on FS16/23/33/40/55, RS27/35.
This kit is suitable for all versions except FS40/55 3x200-240V :
- suitable for FS16/23/33, RS27/35 for all supply voltages (1x208-240V / 3x208-240V / 3x380­415V+N / 3x380-480V without N)
- suitable for FS40/55 for 3x380-480(+N), but NOT for 3x200-240V.
This will improve machine reliability on poor power supply systems with spikes and dips.
2) Needed tools:
2 Wrenches M13
- For 1-ph inverter : Wires 2,5mm², length 50cm (4Pc, preferably blue and black)
- For 3-ph inverter (FS16-23 / FS33 400V / RS27-35) : Wires 2,5mm², length 50cm (6Pc, preferably black)
- For 3-ph inverter (FS33 200V / FS40 / FS55) : Wires 4mm², length 50cm (6Pc, preferably black)
Drill Ø10mm (for metal) Wire cutting and wire stripping pliers
3) Part numbers:
Nr. part number description Quantity
525927 (H616) SERVICE KIT COMPLETE
1 525928 (H956) This service instruction 1 2 525921 (H323) FR-BAL-B-7,5k Power factor reactor 1 3 311902100008 Washer M8 4 4 PRI202000090 Screw M8x16 4 5 310934000008 Nut M8 4
525928 Instruction AC-reactor FS16-55 RS27-35 P3/15
Page 4
www.groupdynamics-laundry.com sales@groupdynamics.lv
4) Instructions:
4.a) Instruction for FS16:
Place the AC-reactor on a suitable place in the machine.
1-ph inverter (standard version):
Mount the AC-reactor in the contactor box. Move the wirings where necessary.
3-ph inverter (3x380-480V without N only):
Since there is used a transformer for the control circuit, it is not possible to mount the AC-reactor in the contactor box.
Therefor mount the AC-reactor on the rear­bridge, beside the water valves.
Drill 4 holes (diam. 10mm) and fix the AC­reactor with the included bolts and nuts.
Make sure that no burs from the drilling can enter the frequency inverter or other components.
525928 Instruction AC-reactor FS16-55 RS27-35 P4/15
Page 5
www.groupdynamics-laundry.com sales@groupdynamics.lv
Make the electrical connection according the scheme and instructions below :
525928 Instruction AC-reactor FS16-55 RS27-35 P5/15
Page 6
www.groupdynamics-laundry.com sales@groupdynamics.lv
1-ph inverter (standard version):
Disconnect the 2 thick wires (normally black and blue) from the inverter contactor (CFI) that come from the mainswitch. Put the small wires back on the contactor terminals.
3-ph inverter (3x380-480V without N only):
Disconnect the 3 wires (normally black) from the inverter contactor (CFI) that come from the mainswitch.
1-ph inverter :
Connect these wires to terminals U1 and V1 of the AC-reactor.
3-ph inverter :
Connect these wires to terminals U1, V1 and W1 of the AC-reactor.
1-ph inverter :
Connect terminals U2 and V2 to the inverter contactor by new wires, to the same terminals where you have disconnected the 2 other wires.
Terminals W1 and W2 of the AC-reactor will not be used if the inverter is 1-phase.
3-ph inverter :
Connect terminals U2,V2,W2 to the inverter contactor by new wires, to the same terminals where you have disconnected the 3 other wires
Make sure to attach and connect all wirings so that they can not be damaged.
525928 Instruction AC-reactor FS16-55 RS27-35 P6/15
Page 7
www.groupdynamics-laundry.com sales@groupdynamics.lv
4.b) Instruction for FS23:
Place the AC-reactor on top of the box of the frequency inverter.
Drill 4 holes (diam. 10mm) and fix the AC­reactor with the included bolts and nuts.
Make sure that no burs from the drilling can enter the frequency inverter or other components.
525928 Instruction AC-reactor FS16-55 RS27-35 P7/15
Page 8
www.groupdynamics-laundry.com sales@groupdynamics.lv
Make the electrical connection according the scheme and instructions below :
525928 Instruction AC-reactor FS16-55 RS27-35 P8/15
Page 9
www.groupdynamics-laundry.com sales@groupdynamics.lv
1-ph inverter (standard version):
Disconnect the 2 wires (normally black and blue) from the inverter contactor (CFI) that come from the mainswitch.
3-ph inverter (3x380-480V without N only):
Disconnect the 3 wires (normally black) from the inverter contactor (CFI) that come from the mainswitch.
1-ph inverter :
Connect these wires to terminals U1 and V1 of the AC-reactor.
3-ph inverter :
Connect these wires to terminals U1, V1 and W1 of the AC-reactor.
1-ph inverter :
Connect terminals U2 and V2 to the inverter contactor by new wires, to the same terminals where you have disconnected the 2 other wires.
Terminals W1 and W2 of the AC-reactor will not be used if the inverter is 1-phase.
3-ph inverter :
Connect terminals U2,V2,W2 to the inverter contactor by new wires, to the same terminals where you have disconnected the 3 other wires
Make sure to attach and connect all wirings so that they can not be damaged.
525928 Instruction AC-reactor FS16-55 RS27-35 P9/15
Page 10
www.groupdynamics-laundry.com sales@groupdynamics.lv
4c) Instruction for FS33/40/55:
Place the AC-reactor on a suitable place in the electrical box at the back of the machine.
Drill 4 holes (diam. 10mm) and fix the AC­reactor with the included bolts and nuts.
Make sure that no burs from the drilling can enter the frequency inverter or other components.
525928 Instruction AC-reactor FS16-55 RS27-35 P10/15
Page 11
www.groupdynamics-laundry.com sales@groupdynamics.lv
Make the electrical connection according the scheme and instructions below :
525928 Instruction AC-reactor FS16-55 RS27-35 P11/15
Page 12
www.groupdynamics-laundry.com sales@groupdynamics.lv
Disconnect the 3 wires (normally black) from the input side of the inverter contactor (CFI).
Connect these 3 wires to terminals U1, V1 and W1 of the AC-reactor. You migth have to replace the original wires by longer ones.
Connect terminals U2,V2,W2 to the inverter contactor (input side) by new wires, to the same terminals where you have disconnected the 3 other wires
Make sure to attach and connect all wirings so that they can not be damaged by vibrations.
525928 Instruction AC-reactor FS16-55 RS27-35 P12/15
Page 13
www.groupdynamics-laundry.com sales@groupdynamics.lv
4.d) Instruction for RS27/35:
Place the AC-reactor on a suitable place in the machine. The most easy is to mount it in the corner of the back panel, but it has the small disadvantage that you always need to disconnect the wires if you want to open the back panel.
Drill 4 holes (diam. 10mm) and fix the AC­reactor with the included bolts and nuts.
Make sure that no burs from the drilling can enter the frequency inverter or other components.
525928 Instruction AC-reactor FS16-55 RS27-35 P13/15
Page 14
www.groupdynamics-laundry.com sales@groupdynamics.lv
Make the electrical connection according the scheme and instructions below :
525928 Instruction AC-reactor FS16-55 RS27-35 P14/15
Page 15
www.groupdynamics-laundry.com sales@groupdynamics.lv
1-ph inverter (standard version):
Disconnect the 2 wires (normally blue and black) from the mainswitch that go to the filter.
3-ph inverter (3x380-480V without N only):
Disconnect the 3 wires (normally black) from the inverter contactor (CFI) that come from the mainswitch.
1-ph inverter :
Connect these wires to terminals U2 and V2 of the AC-reactor.
3-ph inverter :
Connect these wires to terminals U1, V1 and W1 of the AC-reactor.
1-ph inverter :
Connect terminals U1 and V1 of the AC-reactor to the mainswitch by new wires, to the same terminals where you have disconnected the 2 other wires.
Terminals W1 and W2 of the AC-reactor will not be used if the inverter is 1-phase.
3-ph inverter :
Connect terminals U2,V2,W2 to the inverter contactor by new wires, to the same terminals where you have disconnected the 3 other wires
Make sure to attach and connect all wirings so that they can not be damaged.
5) Remarks:
If you have a machine with a transformer for the control circuit, this transformer fulfills the same protection function as the AC-reactor. It means that the AC-reactor is only necessary in the circuit of the inverter, it is not necessary to put the AC-reactor also in the circuit of the control circuit (but it is allowed).
In case you have further technical questions, do not hesitate to take contact with the after sales department of PRIMUS (references at the front page of this document).
525928 Instruction AC-reactor FS16-55 RS27-35 P15/15