Primex P2100, P3000, P4200, P6300 Installation Instructions Manual

Page 1
PRIMEX
MDE Installation Instructions
PRODUCT MODEL CODE
Verge MDE
P2100, P3000, P4200, P6300
The Primex Verge WiFi transparent Media Distribution Enclosures for structured wiring bring reliability when managing today’s inside cable system requirements. Its flexible design provides a convenient, lockable and centralized location for easy installation and distribution of multi-play services within residential and commercial premises.
P3000 STANDARD FRAME & LID INSTALLATION
STEP 1
To ensure a comfortable working height it is recommended that the top of the gang box be installed 36” from the ground using a level.
Note: Leave at least a 2” buffer zone around base to keep clear from perpendicular walls.
WARNING
• DO NOT stretch enclosure walls or lid won’t seat properly.
• DO NOT overtighten mounting screws.
• DO NOT use mounting screws larger than #8.
Note: Adhere to your local electrical code when installing all cabling.
STEP 2
Remove knock outs
Prior to installation, remove the knockouts for the conduit and electrical box using a flush cutter tool.
STEP 3
Install base over top of the gang box using No. 8 flat head screws
Install single screw in corner flange, level, then secure with additional screws.
FOR MORE INFORMATION CONTACT:
T
1.604.881.7875
www.primex.com
F
1.604.881.7835
STEP 4
Connect power and install electrical outlet faceplate
At this stage, connect conduit for outgoing and incoming services and secure with Primex conduit adapters.
1
3
2
4
Fit everything. Together.
452-3113
Page 2
PRIMEX
MDE Installation Instructions
PRODUCT MODEL CODE
Verge MDE
P2100, P3000, P4200, P6300
STEP 5
Measure installation position
Measure distances from edges of enclosure to outside of adjacent studs, floor and ceiling.
STEP 6
Measure, mark, cut and mount drywall
Use measurements from step 5 to mark out drywall. Cut out marked area of drywall. Fit drywall over top of the installed enclosure base and secure.
STEP 7
Paint and affix lid
Place paintshield, paint drywall, and install frame extender (optional) and lid and frame sub-assembly.
STEP 8
Finish installation
Remove paintshield, install locks (optional), and install telecom components (modem, ONT, UPS, eg.).
FOR MORE INFORMATION CONTACT:
T
1.604.881.7875
www.primex.com
452-3113
F
1.604.881.7835
Fit everything. Together.
Page 3
PRIMEX
MDE Accessory Installation Instructions
PRODUCT MODEL CODE
Verge MDE
P2100, P3000, P4200, P6300
Rail Mounting System (RMS)
1
Determine placement of RMP and press pushpins to lock in place.
3
Place component and press bracket arm to hold securely.
2
Slide brackets into place from the side of the mounting plate.
4
Recommended load 5lbs (2.27kg) Place in heavier equipment first.
*Max mounted component
thickness of 3.3”
Universal Mounting System (UMS)
1
Pre-insert up to six pushpins into UMP before placement.
3
Determine placement location of component, cut tape, and thread.
2
Determine placement of UMP and depress pushpins to lock in place.
4
Pull tape and affix to hold and ensure component is secure.
*Recommended load
5lbs (2.27kg)
Shelf Mounting System (SMS)
1
Insert push pins to affix SMS to the Media Distribution Enclosure.
3
Optional mounting tape to secure hardware. (not included)
*All Installation Videos can be found on the Primex website.
2
Mount shelf into place and secure.
4
Can be installed side by side and act as a service divider.
P3000N Narrow Frame & Lid
1
Place enclosures between studs side-by-side.
2
Install frame and lid using the provided No.8 screws.
Verge MDE Frame Extender
1
Snap the frame pieces together.
Align extender and MDE frame.
(P/N: 125-1265)
32
Affix frame and extender together.
FOR MORE INFORMATION CONTACT:
T
1.604.881.7875
www.primex.com
452-3113
F
1.604.881.7835
Fit everything. Together.
Page 4
PRIMEX
MDE Accessories
PRODUCT MODEL CODE
Verge MDE
P2100, P3000, P4200, P6300
Product Description Stock Code
10” UMP w/5’ tape, pushpins (x10) 7” RMP w/RMB2(x2), pushpins (x10) 7” RMP w/RMB(x2), pushpins (x10) 7” RMP w/RMK(x2), pushpins (x10) 10” RMP w/RMB2(x4), pushpins (x10) 10” RMP w/RMB(x4), pushpins (x10) 10” RMP w/RMB2(x2)/RMK(x2), push­pins(x10)
Shelf Mounting System (Single-1/pk) Shelf Mounting Sytem (Service divider-2/pk) Shelf Mounting System (bulk-18/pk)
8-Port Cat5e Data Module 8-Port Cat6 Data Module
8-Port Voice RJ31x Module 6-Port Cat6a Data Module
8-Port Coax Splitter, 1GHz 8-Port Coax Splitter, 3GHz
Electrical Installation Kit 360° Electrical Rotating Outlet
3/4”-1/2” Reducer 1”-3/4” Reducer
Hinged Fiber Spool 3” ABS - Short Legs Fiber Spool 3” ABS - Short Legs Hinged Fiber Spool 3” ABS - Long Legs Fiber Spool 3” ABS - Long Legs
White ABS Hurricane Clip (12/pk) 125-0239
White ABS 24” Stud Bracket 125-1272
Frame Extender, P2100 (20/box) Frame Extender, P3000 (12/box) Frame Extender, P4200 (12/box)
Fiber Splice Tray, 12 Fiber Fiber Splice Tray, 24 Fiber Universal Splice Tray (fusion/mechanical/ribbon) Quick Release Splice Mount
125-1623 125-1655 125-1656 125-1657 125-1658 125-1659 125-1660
125-1541 125-1542 125-1522
125-0986 125-1035
125-0987 125-0975
125-1046 125-1250
125-1355 125-1547
125-1022 125-0936
125-0932 125-0933 125-0931 125-0934
125-1532 125-1533 125-1534
125-1520 125-1521 125-1620
125-1668
Product Description Stock Code
FTC-White ABS w/Screw Cap FTC-White ABS w/Single SC/APC Adapter FTC-White, w/ext. Adapter Mount
FTO-w/2 SC/APC Adapter FTO-w/1 SC/APC Adapter FTO-w/Integrated Splice Tray
F-Connector 3GHz Keystone 125-0961
SC/APC Fiber Keystone w/Shutter 125-0908
Cat5e, 110 IDC, 90° HD Cat5e, 110 IDC, 180° HD
Cat6, 110 IDC, 90° HD Cat6, 110 IDC, 180° HD
3-Line RJ12 Voice Jack 125-0959-WT
Blank keystone 125-0960-WT
Surface Mount Box, 1-Port Surface Mount Box, 2-Port
Customer Premise Outlet (CPO4), 4-Port 125-0911
Single-Gang Wall Plate, 1-Port Single-Gang Wall Plate, 2-Port Single-Gang Wall Plate, 3-Port Single-Gang Wall Plate, 4-Port
Decorative Wall Jack, 1-Port Decorative Wall Jack, 2-Port Decorative Wall Jack, 3-Port Decorative Wall Jack, 4-Port Decorative Wall Plate
Oversize Wall Plate, 1-Port, Glossy Oversize Wall Plate, 2-Port, Glossy Oversize Wall Plate, 3-Port, Glossy Oversize Wall Plate, 4-Port, Glossy Oversize Wall Plate, 6-Port, Glossy
Oversize Wall Plate, 2-Port, W/Cat6 & Coax, Glossy Oversize Wall Plate, 2-Port, W/Cat6 & Coax, Textured
125-0945 125-0873 125-0849
125-0885 125-0889 125-0879
125-0949-WT 125-0948-WT
125-0947-WT 125-0946-WT
125-0962-WT 125-0963-WT
125-0957-WT 125-0958-WT 125-0955-WT 125-0956-WT
125-0951-WT 125-0952-WT 125-0953-WT 125-0954-WT 125-0950-WT
125-1241-WT 125-1236-WT 125-1242-WT 125-1243-WT 125-1244-WT
125-1288-WT
125-1237-WT
FOR MORE INFORMATION CONTACT:
T
1.604.881.7875
F
1.604.881.7835
www.primex.com
452-3113
Fit everything. Together.
Loading...