PRIMETECH 310R Users Manual

IMS
-
310R
iPRECIO® IMS-310R Quick guide ver.1.0.0.E
Read me
Thank you for choosing iPRECIO®, programmable infusion pump for Lab animal for your research/experiments.
This quick guide show you how to use iPRECIO® pump and operate iPRECIO management software.
The iPRECIO® is for use in Laboratory Animal Research ONLY. Not for human
use.
®
Please obey the Guide for the Care and use of laboratory animal by your
organization and or institute when use iPRECIO®.
NOTICE TO THE USER One or more of the following statements may be applicable for this equipment.
Notice (For Model UCD-X10R only)
The provided LAN Cable with a ferrite core shall be used when connect UCD-X10R to a PC and do not replace the LAN cable with other LAN cable.
FCC WARNING
FCC ID: 2ACHIUCDX10R, FCC ID:2ACHI310R
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
IC:XXXXX-2ACHI310R, IC:XXXXX-2ACHIUCDX10
Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
For more information: PRIMETCH CORPORATION TEL:+81-3-3816-0851 E-mail : iprecio@primetech.co.jp URL :www.iprecio.co m
2
www.ipreci o.com
iPRECIO® IMS-310R Quick guide ver.1.0.0 E
INFORMATION TO THE DIGITAL DEVICE USER REQUIREMENT by FCC (For Model UCD-X10R only)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help.
3
www.ipreci o.co m
iPRECIO® IMS-310R Quick guide ver.1.0.0.E
Contents
READ ME .................................................................................................................................. 2
CONTENTS ............................................................................................................................... 4
ABOUT IPRECIO® ................................................................................................................... 5
THE WORLD FIRST WIRELESS PROGRAMMABLE INFUSION PUMP ......................................................... 5
ACCESSORIES WHICH INCLUDED IN IPRECIO
IPRECIO® SYSTEM CONSTRUCTION ............................................................................................... 6
PRODUCT WARRANTY .......................................................................................................... 7
BATTERY LIFE ......................................................................................................................... 8
INSTALL MANAGEMENT APPLICATION ............................................................................. 9
PREPARATION BEFORE START ........................................................................................................... 9
INSTALL IPRECIO
CABLE CONNECTION OF DATA COMMUNICATION UNIT UCD-X10R .................................................. 11
TCP/IP CONNECTION BETWEEN DATA COM UNIT AND CONTROL PC ................................................ 11
PREPARATION BEFORE SOFTWARE USE ........................................................................ 13
FOR THE FIRST TIME EXECUTE MANAGEMENT SOFTWARE ................................................................ 13
USER REGISTRATION .................................................................................................................... 13
ACCESS CONTROL OF SOFTWARE ................................................................................................... 14
CHANGE LANGUAGE ...................................................................................................................... 15
NETWORK SETTING ...................................................................................................................... 15
CREATE INFUSION PROFILE ........................................................................................................... 15
CUSTOMIZE INFORMATION............................................................................................................. 19
START STUDY ........................................................................................................................ 19
START NEW STUDY ....................................................................................................................... 19
CATHETER CONNECTION, PLOMB ADMIN LIQUID AND ACTIVATION. .................................................. 22
PUMP DETECTION .......................................................................................................................... 23
KVO SETTING, START AND COMPLETE ........................................................................................... 24
INFUSION PROTOCOL SETTING ...................................................................................................... 26
START INFUSION PROTOCOL ......................................................................................................... 26
MONITOR THE RUNNING PUMP STATUS ........................................................................................... 27
REPLACE AND/OR REFILL THE MEDICAL SOLUTION ......................................................................... 28
END OF STUDY ............................................................................................................................. 29
SAVE STUDY FILE ......................................................................................................................... 29
EXPORT STUDY FILE ...................................................................................................................... 29
®
MANAGEMENT SOFTWARE ................................................................................. 9
®
STD SYSTEM .......................................................... 5
PRODUCT SPECIFICATION ................................................................................................. 30
www.ipreci o.co m
4
iPRECIO® IMS-310R Quick guide ver.1.0.0 E
About iPRECIO®
A subsequent of the first radio programmable infusion pump
iPRECIO® SMP-310R model is the world first programmable pump which is complete implantable into a laboratory mouse. Utilize high precision mechanical pump technology that was unique developed and controlled by built in microprocessor. An administration protocol can be programmed with dedicated management application software and pump will be work by the programmed protocol with accurate low flow rate ( L/H order) medical solution infusion. In addition the medical solution in the reservoir can be complimented and or replace through septum by transcutaneous even after implanted in an animal.
Accessories which included in iPRECIO® STD System
iPRECIO® system configured with the following accessories.
Small Lab animal micro infusion pump iPRECIO® SMP-310R iPRECIO® management system IMS-310R Data communication unit UCD-X10R (USB Power Adapter*, LAN cable*
included)
Management Software IMS-310R iPRECIO Quick guide (this guide)
(L) Pump in pre-sterilized pack and 5pcs box. (R) Included parts with UCD-X10R
*The attached LAN cable and USB power Adapter cable with a ferrite core shall be
used.
5
www.ipreci o.co m
UCD
-
X10R
iPRECIO® System construction
iPRECIO® IMS-310R Quick guide ver.1.0.0.E
Number name
Refill septum Outlet tube Reservoir Micro cam Pump ID print mark LAN cable connect port USB power adopter connect port Reset switch
6
www.ipreci o.co m
iPRECIO® IMS-310R Quick guide ver.1.0.0 E
Product Warranty
PRIMETECH CORPORATION (hereinafter PRIMETECH) guarantee the product and it’s material are free from defect within the below period which was distributed through the official sales channel. PRIMETECH do not responsible with any problem that caused by using with other company product. Also the product performance is not guaranteed when a customer uses it beyond the original specification.
The defect part will be replaced and or repair by free of charge except, in-transit accident, customer’s fault, breakage caused by abnormal/improper use and damnification cause by PRIMETECH recommendation of use. Any defect parts back to PRIMETCH for replace, always need the RMA format and ship back through original sales channel.
Duration of guarantee
iPRECIO® Micro Infusion Pump SMP-310R: 18 months after manufacturer
iPRECIO® Management System IMS-300: 12 months after shipping date
This warrantee represent any other warrantee and include an implied consent of merchantability and dedicated fitness for purpose, but not limited to.
Liability Limitation Except the warrantee describe in above, PRIMTECH do not responsible any direct, indirect and special loss caused by violence of use condition within the maximum LAW protection. This includes any return loss and or opportunity loss (includes profit loss by contract) with direct, indirect, and damage. This warrantee will be no longer valid when customer (include stuff, member and any other bystander) use iPRECIO® for any other purpose against PRIMETECH sales conditions.
7
www.ipreci o.co m
iPRECIO® IMS-310R Quick guide ver.1.0.0.E
F
low rate
l/hr)
Battery life
(hr)
0.1 408
0.5 384
1.0 360
5.0 216
10.0
144
Battery life
iPRECIO® SMP-310R can continuous operate time below table during product warranty period (After 16 months from manufacturing date)
Please note that below condition makes shorter battery life. :
In case of kept certain period of time without use after power on. (After
power on, internal circuit becomes active and consume battery power by standby power requirement)
In case of not storage under proper circumstances. (Under frequent
temperature swing or exposed in over storage temp range in spec may cause increasing self-discharge of battery)
8
www.ipreci o.co m
iPRECIO® IMS-310R Quick guide ver.1.0.0 E
Install management application
Preparation before start
iPRECIO® Management software install CD Windows 7/Windows8/Windows 10 installed and LAN port ready PC Data communication unit UCD-X10R (data com unit)
UCD-X10R main body USB to DC adapter LAN cable (Cross over cable with Ferrite core)
Install iPRECIO® management software
PC setting should be:
Off the screen saver Get into the control panel Power option of “Change when PC sleep” and set
“Put the computer to sleep” = “Never”
1. Run the “setup.exe” in a install CD.
2. When the startup window appeared, click “Next>”. Then setup wizard window comes up, click “Next>” again.
3. Chose the program files store folder and click “Next>”. Subsequently confirmation screen open, then click “Next>”. For this step the installation will be started.
9
www.ipreci o.co m
iPRECIO® IMS-310R Quick guide ver.1.0.0.E
4. When install complete windows appears, click “Close”.
5. Check start menu that the following software installed.
iPRECIO® Management Software IMS-X10R Utility Base Station Manager Utility Pump Database Manager
6. Three of those software has been installed, then the management software install is successful.
10
www.ipreci o.co m
Loading...
+ 21 hidden pages