Prima Klima PK250-XLE Instructions Manual

Instructions Prima Klima EN PK250-XLE
Safety Information
This machinery must not be put into operation until prior to reading mounting instructions and safety information. All fans are intended for transportation of air in air handling systems. If
They are meant to be used after building them into machines or duct systems or after contact protection grid have been installed. Fans with duct connections must be connected to ducts on both sides (inlet/outlet). When there is a risk of water entering the motor, via the ducts, external protection is required. No moving parts shall be accessible after installation. The fans are not to be used in hazardous environments or connected to flue ducts. The fans must not be
installed outdoors (with exception of roof fans and fans with, for this purpose: corresponding IP
class). If the fans are installed without insulation in non-heated areas there is a risk of condensation. Safety accessories (i.e. motor protection, safety grille) may not be dismounted, short cut or disconnected. CAUTION! Before servicing or maintenance, switch off power, (all­pole circuit breaker), and make sure the impeller has come a standstill. CAUTION! The fans can have sharp edges and corners which may cause injuries. CAUTION! Be careful when opening the fans service-hatches (swing-out), the fan and motor assembled on the hatch is relatively heavy.
Transportation and Storage
All fans are packaged at the factory to withstand normal transport handling. When handling the goods use suitable lifting equipment in order to avoid damage to fans and personnel. Do not lift the fans by the connecting cable, connection box, impeller or inlet cone. Avoid blows and shock loads. Store the fans in a dry place protected from weather and dirt until final installation.
Operation
Before initial operation, check the following:
- Electrical connection has been properly completed.
- Protective conductor has been connected.
- Motor protection installed.
- Safety devices in place (protection grid)
- Leftover installation materials and foreign materials have been removed from the casing.
When putting into operation, check the following:
- Connection data corresponds to the specifications on the nameplate: Maximum voltage +6%,
-10%, according to IEC 38. Rated current must not be exceeded with more than 5% at rated voltage. CAUTION! When speed regulating by reducing the voltage the motor current may exceed the rated current at a lower voltage. In this case the motor windings are protected by the thermal contact. The minimum static fall of pressure must observe.
- The direction of rotation should correspond to direction of rotation arrow
- Smoothness of motor operation, (no abnormal noises)
- Fans must only be operated by a person that has sustainable knowledge or education within this field or handling must be carried out with the supervision of such person.
Radnice u Rokycan 594 CZ-33828 Czech Republic sales@primaklima.com Tel.: 00420 371 795 340 www.primaklima.com
Sound levels exceeding 68, 72 or 74 dB may occur depending on model and size (see online catalogue at www.primaklima.com for information).
Maintenance, Service and Repair
Before maintenance, service or repairs make sure that:
- Power supply is interrupted (all-pole circuit breaker).
- Fan impeller has come to a complete standstill
- Observe personnel safety regulations!
The fan should be cleaned when necessary, at least 1/year to avoid imbalance and unnecessary damage to the bearings. A filter will prolong the time interval between each cleaning of the fan. (It is sometimes recommended to install a filter guard). The fan bearings are maintenance free and should only be replaced if damaged. Do not use a high-pressure cleaner (steam jet) when cleaning the fan. Make sure the fan impeller's balance weights are not moved or the fan
impeller distorted. Listen for abnormal operating noise.
Manufacturer
PRIMA KLIMA TRADING CZ s.r.o. Radnice 594, 33828 Radnice u Rokycan, Czech Republic Phone: +420371795340, Fax: +420371795343, Email: support@primaklima.com, www.primaklima.com
Radnice u Rokycan 594 CZ-33828 Czech Republic sales@primaklima.com Tel.: 00420 371 795 340 www.primaklima.com
Deutschland: https://www.growland.net
Europe: https://www.growland.biz
France: https://www.growland.fr
España: https://www.growland.es
Österreich: https://www.growland.at
Nederland: https://www.growland.nl
Italia: https://www.growland.it
United Kingdom: https://www.growland.co.uk