Primacoustic THUNDERTILE-2X2-RE, THUNDERTILE-2X2-SQ, THUNDERTILE-2X4-SQ Data Sheet

ENGINEERING DATA SHEET
0
tHunDeRtile
ThunderTile™ ceiling panels combine the acoustic absorption of Broadway glass wool panels with the sound-stopping mass of 1/2” (12mm) gypsum board. This composite tile is ideal for use in boardrooms, schools, legal and
medical ofces where room acoustics need to be controlled and privacy
ThunderTiles are fully encapsulated with a micromesh then covered in a bright white glass wool facing to blend with typical drop-ceiling applications.
ThunderTiles have been tested to meet stringent Class-1 re ratings,
making them suitable for use in all residential and commercial spaces. Panels are available in two standard drop-in ceiling tile sizes, in both trim and reveal edge treatments for 15/16” (24mm) ceiling grids.
SPECIFICATIONS:
CORE MATERIAL Formed, semi-rigid inorganic glass bers, Gypsum
BACKING 1/2” (12mm) gypsum board
FACING Glass wool tissue micromesh sealed with water based latex paint
BACKING Foil
COLOR Absolute White
GRID SPACING 15/16”, T24 (24mm grid)
GRID SIZES 2’ x 2’ (61cm x 61cm) and 4’ x 2’ (122cm x 61cm)
CEILING ATTENTUATION CLASS
LIGHT REFLECTANCE 0.84
RECYCLED CONTENT Up to 40%
LEED ELIGIBLE Yes
46
Sound blocking gypsum layer.
Acoustic glass wool layer.
DIMENSIONS:
ORDER NO. DESCRIPTION HEIGHT WEIGHT DEPTH EDGE
P200-2424-00 2’ x 2’ Trim
P201-2424-00 2’ x 2’ Reveal Reveal 8
P200-2448-00 4’ x 2’ Trim
23.75” x 23.75”
(603mm x 603mm)
47.75” x 23.75”
(1213mm x 603mm)
8.9 lbs
(4.0 kg)1”(27mm)
12.8 lbs” (8.1 kg)1”(27mm)
Trim 8
Trim 4
Trim edge treatment.
BOX QTY.
ABSORPTION CHARACTERISTICS:*
Sound absorption coefcient data.
PANEL DEPTH 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz NRC
1” (27mm) Depth 0.10 0.35 0.5 0.84 0.94 0.97 0.73
* Estimated acoustic absorption based StratoTile testing performed by Muller - BBM and 1/4 wavelegnth calculation.
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
SOUND ABSORPTION COEFFICIENTT
0.3
0.2
0.1
0
z
63H
125Hz
160Hz
200Hz
250Hz
315Hz
400Hz
500Hz
FREQUENCY (Hz)
1kHz
630Hz
800Hz
2kHz
1.6kHz
1.25kHz
4kHz
2.5kHz
5kHz
3.15kHz
FIRE & BURN PERFORMANCE:
TEST CLASS FLAME SPREAD SMOKE DENSITY
ASTM E 84-05** 1 OR A 5 FSI 15 SD
CAN/UL-S102 1 OR A 2 FSC1 10 SD
BS 476 Parts 6 & 7 B
**Standard test methods for surface burning characteristics of building materials is used to
measure and describe the response of materials, products, or assemblies to heat and ame under controlled conditions, but does not by itself incorporate all factors required for re-hazard or re-risk assessment of the materials, products, or assemblies under actual re condition.
.9”
(24mm)
1.06” (27mm)
Reveal edge treatment.
.9”
(24mm)
1.06” (27mm)
.39” (10mm)
Trim edge treatment. Reveal edge treatment.
.59” (15mm)
.59” (15mm)
.39” (10mm)
.47” (12mm)
.47” (12mm)
Primacoustic is a division of Radial Engineering Ltd. • 1588 Kebet Way Port Coquitlam, BC V3C 5M5 • Tel: 604-942-1001 Fax: 604-942-1010
www.primacoustic.com • info@primacoustic.com • Primacoustic Engineering Data Sheet • Part #R870 2200 00 • Copyright © 2016 • Subject to change without notice.