ENGINEERING DATA SHEET
tHunDeRtile
ThunderTile™ ceiling panels combine the acoustic absorption of Broadway
glass wool panels with the sound-stopping mass of 1/2” (12mm) gypsum
board. This composite tile is ideal for use in boardrooms, schools, legal and
medical ofces where room acoustics need to be controlled and privacy
maintained by reducing sound transmission between rooms.
ThunderTiles are fully encapsulated with a micromesh then covered in a
bright white glass wool facing to blend with typical drop-ceiling applications.
ThunderTiles have been tested to meet stringent Class-1 re ratings,
making them suitable for use in all residential and commercial spaces.
Panels are available in two standard drop-in ceiling tile sizes, in both trim
and reveal edge treatments for 15/16” (24mm) ceiling grids.
SPECIFICATIONS:
CORE MATERIAL Formed, semi-rigid inorganic glass bers, Gypsum
BACKING 1/2” (12mm) gypsum board
FACING Glass wool tissue micromesh sealed with water based latex paint
BACKING Foil
COLOR Absolute White
GRID SPACING 15/16”, T24 (24mm grid)
GRID SIZES 2’ x 2’ (61cm x 61cm) and 4’ x 2’ (122cm x 61cm)
CEILING
ATTENTUATION
CLASS
LIGHT REFLECTANCE 0.84
RECYCLED CONTENT Up to 40%
LEED ELIGIBLE Yes
46
Sound blocking gypsum layer.
Acoustic glass wool layer.
DIMENSIONS:
ORDER NO. DESCRIPTION HEIGHT WEIGHT DEPTH EDGE
P200-2424-00 2’ x 2’ Trim
P201-2424-00 2’ x 2’ Reveal Reveal 8
P200-2448-00 4’ x 2’ Trim
23.75” x 23.75”
(603mm x 603mm)
47.75” x 23.75”
(1213mm x 603mm)
8.9 lbs
(4.0 kg)1”(27mm)
12.8 lbs”
(8.1 kg)1”(27mm)
Trim 8
Trim 4
Trim edge treatment.
BOX
QTY.
ABSORPTION CHARACTERISTICS:*
Sound absorption coefcient data.
PANEL DEPTH 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz NRC
1” (27mm) Depth 0.10 0.35 0.5 0.84 0.94 0.97 0.73
* Estimated acoustic absorption based StratoTile testing performed by Muller - BBM and 1/4
wavelegnth calculation.
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
SOUND ABSORPTION COEFFICIENTT
0.3
0.2
0.1
0
z
63H
125Hz
160Hz
200Hz
250Hz
315Hz
400Hz
500Hz
FREQUENCY (Hz)
1kHz
630Hz
800Hz
2kHz
1.6kHz
1.25kHz
4kHz
2.5kHz
5kHz
3.15kHz
FIRE & BURN PERFORMANCE:
TEST CLASS FLAME SPREAD SMOKE DENSITY
ASTM E 84-05** 1 OR A 5 FSI 15 SD
CAN/UL-S102 1 OR A 2 FSC1 10 SD
BS 476 Parts 6 & 7 B
**Standard test methods for surface burning characteristics of building materials is used to
measure and describe the response of materials, products, or assemblies to heat and ame under
controlled conditions, but does not by itself incorporate all factors required for re-hazard or re-risk
assessment of the materials, products, or assemblies under actual re condition.
.9”
(24mm)
1.06” (27mm)
Reveal edge treatment.
.9”
(24mm)
1.06” (27mm)
.39” (10mm)
Trim edge treatment. Reveal edge treatment.
.59” (15mm)
.59” (15mm)
.39” (10mm)
.47” (12mm)
.47” (12mm)
Primacoustic is a division of Radial Engineering Ltd. • 1588 Kebet Way Port Coquitlam, BC V3C 5M5 • Tel: 604-942-1001 Fax: 604-942-1010
www.primacoustic.com • info@primacoustic.com • Primacoustic Engineering Data Sheet • Part #R870 2200 00 • Copyright © 2016 • Subject to change without notice.