Push-on Impalers™ are designed to provide the installer with a simple,
quick and effective method of mounting Broadway™ glass wool panels
onto walls without causing serious surface defacement. Primacoustic
Push-On Impalers allow the installer to push the Broadway panel straight
onto the Impaler clip, making it easier to align panels in clusters or side by
side with accuracy.
The Push-On Impaler features a series of sharp protruding darts that
penetrate the panel and secure it in place. To ensure panels do not get
dislodged after installation, applying a dab of construction adhesive to the
center of the Impaler during the mounting process adds a level of security
and reduces opportunity for tampering. Impalers are installed using typical
sheetrock anchors and screws.
suRFAce iMPAleR
Surface Impalers™ are designed to provide the installer with a simple,
quick, and effective method of mounting Broadway™ glass wool panels
onto walls without causing serious surface defacement. Primacoustic
Surface Impalers allow the installer to simply pull the panel down onto
the Impaler clip quickly and efciently, while allowing for some levelling
adjustability after the panel is installed.
The Surface Impaler features four sharp darts that penetrate the panel and
secure it in place. To ensure panels do not get dislodged after installation,
applying a dab of construction adhesive to the center of the Impaler during
the mounting process adds a level of security and reduces opportunity
for tampering. Impalers are installed using typical sheetrock anchors and
screws.
Push-On Impaler:
Surface Impaler:
3” (77mm)
4” (102mm)
3” (77mm)
4” (102mm)
SPECIFICATIONS:
ORDER NUMBERPush-On: F101-1003-00 Surface: F101-1000-00
MATERIAL20 gauge galvanized steel
DIMENSIONS3” (76mm) x 4” (102mm)
ATTACHMENT POINTS2 (Use appropriate fastener for wall surface)
MAX LOAD LIMIT12 lbs. (5.4 kg.) Dependant on wall fastener
NUMBER PER BOX24 per box
RECOMMENDED MINIMUM NUMBER OF IMPALERS PER PANEL:*
*Primacoustic recommends a certain number of impalers per panel as the minimum required for
safe installation based on panel depth and weight. For additional security, you may wish to increase
these numbers per panel and also combine with construction adhesive.
No. of
Impalers
Needed*
4” (102mm)
4” (102mm)
Flush mount impaler
clips should be located
approximately 4 inches
(102mm) or more from
the panel edges.
12” x 12”24” x 24”12” x 48”24” x 48”
Primacoustic is a division of Radial Engineering Ltd. • 1588 Kebet Way Port Coquitlam, BC V3C 5M5 • Tel: 604-942-1001 Fax: 604-942-1010
Corner Impalers™ are designed to provide the installer with a simple,
quick and effective method of mounting Broadway™ glass wool acoustic
panels into corners to create bass traps. The Corner Impaler features a
45º angle design that positions a panel across a typical 90° corner without
causing serious defacement of the wall surface.
The panel is held in place using a series of sharp protruding darts that
penetrate the panel to secure it during installation. To ensure panels do
not get dislodged after installation, a dab of construction adhesive may be
applied to the impaler darts during the mounting process adding a higher
level of security and reducing opportunity for tampering. Impalers are
installed using typical sheetrock anchors and screws.
OFFset iMPAleR
Offset Impalers™ provide the installer with a simple, quick and effective
method of mounting Broadway™ glass wool acoustic panels onto wall
surfaces while creating an air cavity behind the panel to increase bass
absorption.
The Offset Impaler features a U-shaped design that holds the panel from
the wall surface by 3.5” making it easy to align with typical 2” x 4” studs.
The panel is held in place using a series of sharp protruding darts that
penetrate the panel to secure it during installation.
5” (126mm)
3.5” (89mm)
5” (127mm)
3” (77mm)
3” (77mm)
3”
(77mm)
To ensure panels do not get dislodged after installation, applying a dab of
construction adhesive to the impaler darts during the mounting process
adds a level of security and reduces opportunity for tampering. Impalers
are installed using typical sheetrock anchors and screws and therefore,
will not cause serious surface defacement to the wall.
SPECIFICATIONS:
ORDER NUMBERCorner: F101-1001-00 Offset: F101-1002-00
MATERIAL20 gauge galvanized steel
DIMENSIONS
3” (76mm) x 5” (127mm)
Corner = 45° angle for 90° corners.
Offset = 3.5” (89mm) from wall surface
ATTACHMENT POINTS4 (Use appropriate fastener for wall surface)
MAX LOAD LIMIT12 lbs. (5.4 kg.) Dependant on wall fastener
NUMBER PER BOX8 pieces
Three inch Broadway panels with and without a 3.5” air space.
The Helix™ is a solid zinc die-cast device that integrates an eye hole and
a wide screw that create a reliable and sturdy anchor for hanging any
Primacoustic panel as an acoustic cloud using the adjustable SlipNot™
suspension system shown below.
SPECIFICATIONS:
ORDER NUMBERF101-1006-00
MATERIALPlastic
MAX LOAD LIMITS45 lbs. (20.4 kg.) per anchor
NUMBER PER BOX12 pieces
cORKscReW
Designed to create a vertical bafe using any Broadway or Paintables
panel, the Corkscrew™ is a tensioned steel screw that twists into the
edge of a panel for placement overhead. Combining the Corkscrew with
the SlipNot enables the panel to be quickly adjusted to achieve a uniform
height.
SPECIFICATIONS:
ORDER NUMBERF101-1004-00
MATERIALSteel
MAX LOAD LIMITS45 lbs. (20.4 kg.) per anchor
NUMBER PER BOX12 pieces
sliPnOt
Designed to suspend Primacoustic clouds and bafes, the SlipNot™ is a
unique 76” (193cm) suspension cable system that combines aircraft steel
rope with a cam-style releasable hook for easy height adjustment at one
end and a simple eye-sling at the other. One merely attaches the sling to a
suspension point and clips the hook onto the Primacoustic cloud or bafe
using either the Corkscrew or Helix panel mounting screws.
SPECIFICATIONS:
ORDER NUMBERF101-1011-00
MATERIALSteel
MAX LOAD LIMITS45 lbs. (20.4 kg.) per anchor
NUMBER PER BOX12 pieces
CABLE LENGHT76” (193cm)
Primacoustic is a division of Radial Engineering Ltd. • 1588 Kebet Way Port Coquitlam, BC V3C 5M5 • Tel: 604-942-1001 Fax: 604-942-1010
Suspending Broadway panels has never been easier or faster. Simply twist
Cloud Anchors into the back of any 2” (5cm) or 3” (7.5cm) Broadway panel
for a strong and secure installation.
The integrated eye-screw allows overhead suspension by tie-wire or chain.
The Cloud Anchor is perfect for hanging Broadway acoustic panels in
restaurants, call centers, boardrooms, schools and ofces.
SPECIFICATIONS:
ORDER NUMBERF101-1007-00
MATERIALPlastic and steel
MAX LOAD LIMITS45 lbs. (20.4 kg.) per anchor
NUMBER PER BOX12 pieces
ENGINEERING DATA SHEET
2” Cloud Anchor Ceiling
Mounted
2” Wall Mounted
SOUND ABSORPTION COEFFICIENT
FREQUENCY (HZ)
2” Urethane Wall Mounted
Rotofast™
snAP-On AncHOR
The Snap-On Anchor locks the panel onto any at surface for installations
where panels need to be mounted securely. Simply twist the anchor into
the panel using the included tool and attach the corresponding locking pins
to the wall or ceiling. The panel clicks and locks onto these pins, providing
safe overhead/ceiling mounting and secure wall mounting in high trafc
areas.
SPECIFICATIONS:
ORDER NUMBERF101-1009-00
MATERIALPlastic
MAX LOAD LIMITS45 lbs. (20.4 kg.) per anchor
NUMBER PER BOX50 pieces, tool, marking plugs
Primacoustic is a division of Radial Engineering Ltd. • 1588 Kebet Way Port Coquitlam, BC V3C 5M5 • Tel: 604-942-1001 Fax: 604-942-1010