Prier P-754 Installation, Operation & Maintenance Instructions Manual

Page 1
PRIER Products, Inc.
4515 E 139th St.
Grandview, MO 64030
800-362-9055
www.PRIER.com/P-754
Installation, Operation & Maintenance Instructions for the
PRIER P-754 Hot & Cold Commercial Wall Hydrant
*Please leave this sheet for the property owner*
hydrant available. Your P-754 will provide you years of dependable service with little or no maintenance.
Please note: Your P-754 hydrant has drain holes under the packing nut. After shuto󰀨, the drain holes will allow water to drain for a few moments to prevent freezing. This is normal and according to design.
Installation:
Installation procedures may vary slightly depending on the application and choice to use the P-754BX1 hydrant box. The P-754 wall hydrant is available only in the M inlet (¾” MPT):
1. Determine the location for the installation of the hydrant. Ensure there is adequate work room in the interior of the structure for securing the hydrant to the plumbing piping.
2. For installation without a box, use the cardboard template located on the hydrant box, cut a 4” Wide x 4 1/2” Tall open­ing through the wall in the desired position for the installation.
3. For installation with a box, use the cardboard template located on the box, cut a 6” Wide x 7 1/2” Tall opening through the wall in the desired position for the installation.
4. Insert the hydrant into the cutout and temporarily secure to connect the water supply. If using a box, fully secure the box to the structure (can use the optional (4) 3/8-16 lugs on the back of the box), loosely install the stainless steel mounting plate and hydrant to the box using the (4) #10-24 screws provided.
5. If you are planning to solder the connection, be certain to keep heat away from the threaded connection as there is a plastic check valve installed to prevent thermal migration.
6. Connect the water supply piping to the hydrant as desired. Make sure to connect the hot supply to the inlet marked with RED. With a closed-end hose on the valve creating back pressure, test the installation for leakage.
7. After the water supply connection is made, secure the mounting plate to the structure with appropriate fasteners, or if using a box secure the (4) screws to hold the hydrant to the box.
Operation:
Operation of the P-754 Commercial Wall Hydrant is a simple process. Water ows through the hydrant after turning the loose key one full turn counter-clockwise to the “on” position. The hydrant will achieve maximum ow at 2 1/2 full turns.
At any time during the “on” position the temperature dial can be rotated clockwise (to the right) for cold water or counter-
clockwise (to the left) for hot water. Turn o󰀨 the hydrant by turning the loose key fully clockwise to the “o󰀨” position. The
hydrant will drain for a few moments. If the dripping persists after a few moments, tighten the key slightly until the dripping stops. Be careful not to overtighten the hydrant.
The P-754 incorporates an integral ASSE 1052 atmospheric anti-siphon vacuum breaker that, in the rare occurrence of a back siphon- age, opens to the atmosphere preventing contamination of the water supply.
As well as an atmospheric vacuum breaker, the P-754 incorporates a check valve in the rare case that water is forced backwards into the valve.
*ALWAYS REMOVE HOSE DURING FREEZING TEMPERATURES*
Maintenance:
The P-754 Heavy Commercial Wall Hydrant leaves the factory fully air tested and operational. It is treated with an FDA
approved lubrication. The hydrant requires no scheduled maintenance to provide long life. If the stem is removed, the
bypass O-Ring needs to be replaced and lubricated with an FDA approved lubricant to avoid tearing.
Page 2
4515 East 139th Street Grandview, MO 64030 (800) 362-9055 Fax (800) 362-1463 www.PRIER.com
Replacement Parts & Stems
11
12
14
15
*When assembling the vacuum breaker, ensure the
65
dome is facing out on the check spider and the step is facing out on the silicone washer.
16
7 8
1
13
10
ID Part No. Description ID Part No. Description
1 See Below Stem Assembly, Contains: 5, 14 310-6009 1” Hose Piece for C-636 (NP Brass)
P-231-0604 Stem for 4” C-634 Hydrant, 4 11/16” OAL 5 336-0001 O-Ring Worm Sleeve
P-231-0606 Stem for 6 “ C-634 Hydrant, 6 11/16” OAL 6 336-6001 O-Ring Worm Drive
P-231-0608 Stem for 8” C-634 Hydrant, 8 11/16” OAL 7 337-6001 Check Spider-Vacuum Breaker
P-231-0610 Stem for 10” C-634 Hydrant, 10 11/16” OAL 8 346-6001 Diaphragm-Vacuum Breaker
P-231-0612 Stem for 12” C-634 Hydrant, 12 11/16” OAL 10 C-108KT-808 Loose Key on Lanyard
P-231-0614 Stem for 14” C-634 Hydrant, 14 11/16” OAL 11 C-634KT-802 Stopper Kit, Includes Stopper and Pin
P-231-0616 Stem for 16” C-634 Hydrant, 16 11/16” OAL 12 324-0004 Pin Only
P-231-0618 Stem for 18” C-634 Hydrant, 18 11/16” OAL 13 C-634KT-806 Vacuum Breaker Assembly
P-231-0620 Stem for 20” C-634 Hydrant, 20 11/16” OAL 14 C-634KT-808 Worm Sleeve with O-Ring, Pin and Tool
P-231-0622 Stem for 22” C-634 Hydrant, 22 11/16” OAL 15 C-634KT-809 Worm Drive Assembly with O-Ring
P-231-0624 Stem for 24” C-634 Hydrant, 24 11/16” OAL 16 C-634WCR Wall Clamping Ring
2 300-6003 Valve Stem Cap (NP Brass) 17 399-0001 Secondary Check for ASSE 1052
3 300-6004 3/4” Hose Piece (NP Brass) C-634KT-807 C-634 Overhaul Kit, Contains: 10, 11, 12, 13, 14
2
3 17
Rough-In Dimensions
5”
5.5”
Specs
Furnish and install Model P-754 Heavy Commercial Wall Hydrant manufactured by PRIER Products, Inc. Hydrant shall have automatic draining
capabilities with integral vacuum breaker/backow preventor. Hydrant shall ow 19 gallons per minute minimum at 25 PSI Di󰀨erential and be at full ow in 2 handle rotations. Hydrant shaft shall be brass with threaded and sealed connections. Hydrant shall have 3/4” hose connection with freezeless water ow and self-draining functions, one piece valve plunger, satin nickel nish, brass operating rod with positive triple seal shuto󰀨
mechanism. Hydrant shall be approved under ASSE 1052 standard. Operating key & wall clamping ring to be furnished with each hydrant. Hydrant insertion length to be * inches.
Optional: Furnish and install ush-mount hydrant box for each valve. Hydrant box shall be manufactured of solid cast brass. Box may be installed
separately and hydrant be insertable and removable from front of the box. Access to the hydrant box shall be provided by the same operating key as the valve. *4” to 24” in 2” increments.