Prier 478-D, 479-T, 480-C, 481-S, 482-F Installation Manual

...
Page 1
PRIER Products, Inc.
4515 E 139th St.
Grandview, MO 64030
800-362-9055 Fax: 800-362-1463
www.PRIER.com
Installation, Operation & Maintenance Instructions for the
PRIER Manseld Style 400 Diamond Series Wall Hydrant
*Please leave this sheet for the property homeowner*
Installation:
Installation procedures may vary slightly depending on the seat option purchased and the installation inlet options. PRIER Manseld Style 400 Series wall hydrants are available with the following inlet options:
478-D Style 1/2” MIP x 1/2” SWT Bore 1” Hole 479-T Style 3/4” MIP x 1/2” FIP Bore 1 1/8” Hole 480-C Style 1/2” CPVC Bore 1” Hole 481-S Style 1/2” SWT x 3/4” Push-On Bore 1” Hole 482-F Style 3/4” MIP x 3/4” SWT Bore 1 1/8” Hole 490-X Style 1/2” Crimp PEX Bore 1” Hole 491-W Style 1/2” Wirsbo® PEX Bore 1” Hole 492-FX Style 3/4” Crimp PEX Bore 1 1/8” Hole 493-FW Style 3/4” Wirsbo® PEX Bore 1 1/8” Hole
1. Determine the location for the installation of the hydrant. The valve must be installed into a heated area of the struc­ture that will not drop below freezing. Ensure there is adequate work room in the interior of the structure for securing the hydrant to the plumbing piping. Bore the hole size listed above through the wall in the desired position for the installation.
2. All freezeless wall hydrants require a slight downward pitch to aid the draining process of the hydrant once the prod­uct is turned to the “off” position. PRIER has included an appropriate siding wedge to install behind the wall ange of the hydrant. This ensures proper drainage pitch results after installation.
3. Position the spout of the hydrant in the downward position. From the interior of the structure, utilize the spout aligning mark on the seat. When the mark is pointed down, the spout is oriented in the proper position on the outside of the
structure.
4. If you are planning to solder the connection (478, 481 or 482 style seats), be certain the hydrant is in the fully open position to prevent seat damage from the heat.
5. Connect the water supply piping to the freezeless wall hydrant as desired. With a closed-end hose attached creating
back pressure, test the installation for leakage.
6. After the water supply connection is made, secure the hydrant to the structure using appropriate screws through the two mounting holes on the casted back ange and siding wedge.
Operation:
Operation of the PRIER Manseld Style 400 Diamond Series Wall Hydrant is a simple process. Water ows through the hydrant after turning the handle counter-clockwise to the “on” position. Turn off the hydrant by turning the handle clock-
wise to the “off” position.
The hydrant will drain for a few moments. If the dripping persists after a few moments, tighten the handle slightly until the dripping stops. Be careful not to overtighten the hydrant.
The 400 Series incorporates an integral atmospheric anti-siphon vacuum breaker that, in the rare occurrence of a back siphonage, opens to the atmosphere preventing contamination of the water supply.
As well as an atmospheric vacuum breaker, the 400 Series incorporates a backow preventer that operates as a check valve in the rare case that water is forced backwards into the valve. The backow preventer has been tested to 125 PSI
pressure.
*ALWAYS REMOVE HOSE DURING FREEZING TEMPERATURES*
*INTENDED FOR IRRIGATION USE AND OUTDOOR WATERING*
Maintenance:
The PRIER Manseld Style 400 Diamond Series Wall Hydrant leaves the factory fully air tested and operational. It is treated with an FDA approved lubrication. The hydrant requires no scheduled maintenance to provide long life.
Page 2
4515 East 139th Street Grandview, MO 64030
(800) 362-9055 Fax (800) 362-1463
www.PRIER.com
Replacement Parts
2
3
1
6
7
8
ID Part No. Description
1 See Below Stem Assembly, Contains: 1, 2, 3, 4, 5
2 C-134KT-802
3 336-0002 Backow Check Valve for 400 Series
4 324-1006 Washer (Stainless Steel)
5 339-3002
4
5
9
6 337-3001 Left Hand Thread Packing Nut (Plastic)
7 630-7965
630-7975
8 337-3012 Space Wedge (Grey, Plastic)
337-3013 Space Wedge (Beige, Plastic)
9 630-7500
630-7755
Seat Washer Replacement Kit (00 Beveled)
Packing for Left Hand Packing Nut (Graphite)
Handle & Screw Kit (Grey Plastic Handle & Stainless Steel Screw)
Handle & Screw Kit (Beige Plastic Handle & Stainless Steel Screw)
Universal Vacuum Breaker Replacement Kit
Service Kit for 300/400/500 Series
Contains: 2, 3, 4, 5, 6
3
/4”
Hydrant Length
Replacement Stems
Part No. Style Description Stem Length
M-231-3204 H Stem for 4” 400 Series Hydrant 6 9/16” OAL
M-231-3206 H Stem for 6 “ 400 Series Hydrant 8 9/16” OAL
M-231-3208 H Stem for 8” 400 Series Hydrant 10 9/16” OAL
M-231-3210 H Stem for 10” 400 Series Hydrant 12 9/16” OAL
M-231-3212 H Stem for 12” 400 Series Hydrant 14 9/16” OAL
M-231-3214 H Stem for 14” 400 Series Hydrant 16 9/16” OAL
630-8500
*The 630-7755 Wall Hydrant Repair Kit includes parts for the
300, 400 and 500 Series hydrants, some of which are not
pictured here. When repairing a hydrant you will have parts left over.
*The 630-7500 Universal Vacuum Breaker Kit ts all current and past PRIER and Manseld style residential hydrants.
Stem Overall Length (OAL)
H Style Manufactured April 2013 - Present
Complete Service, Handle & Vacuum Breaker Kit
**For the old style 400 Series wall hydrant stems, see 400 Series retired style spec sheet at www.PRIER.com. For older styles made prior to 2007, see the retired 500 Series spec sheet.
Loading...