Pridiom PGD970DES User Manual

Page 1
PGD970DES
USER MANUAL
VER. 1-261112
www.pridiom.com
Page 2
120 V / 60 Hz mains supply. The installation must be in accordance with
THANK YOU
Thank you for choosing this innovative Pridiom dehumidifier.
This instruction manual describes the many benefits and advanced features that this unique product has to offer.
This dehumidifier is a tough, industrial unit designed to be used almost any­where that dry air is required. Desiccant/Absorption dehumidifiers are especially suited to applications where low relative humidities are needed and work well over a wide tempera-ture range.
Pridiom specializes in complete indoor humidity control. Our world class products incorporate the latest technological developments and are designed to create a quality environment.
It is important that you read these instructions carefully before installing and using your new dehumidifier. Please keep them in a safe place for future reference.
SAFETY
For safety reasons, read this information carefully before operating. Persons who are not familiar with this type of product must not use it.
This appliance must be grounded and should only be connected to a grounded
the regulations of the country where the unit is used.
This unit is designated for indoor operation.
The dehumidifier is safe, however, as with other electrical appliance, use it with care.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
Do not clean the dehumidifier by spraying it or immersing it in water.
Do not insert any object into the opening of the dehumidifier.
Disconnect from the mains before cleaning the unit or any of its compo-
Never connect to an electrical outlet using an extension cord. If an outlet
Any service other than regular cleaning or filter replacement should be
W supply cord is damaged, it must be replaced by an approved service repre- sentative or a similar qualified person in order to avoid any hazards.
There should be direct access to the electrical plug after connecting the power!
Do not use your dehumidifier under the following conditions:
Page 3
Children should be supervised to ensure that they do not play with the appliance.
Do not clean the dehumidifier by spraying it or immersing it in water.
Do not insert any object into the opening of the dehumidifier.
Disconnect from the mains before cleaning the unit or any of its compo-
nents.
Never connect to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a licensed electrician.
Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to do so could result in a loss of warranty. Your dehumidifier is supplied with an electrical cable and a grounded plug. Should it be necessary to replace this plug at any time, you must use a grounded electrical plug.
W
arning! Never operate this appliance if it has a damaged cord or plug. If the supply cord is damaged, it must be replaced by an approved service repre­sentative or a similar qualified person in order to avoid any hazards.
There should be direct access to the electrical plug after connecting the power!
Do not use your dehumidifier under the following conditions:
This product is not
made for DIy repair
If the power cable wires are frayed or cut
When small children may be left unattended
Where the power cable may be damaged
Where it may be damaged by chemicals
If there is a risk of liquid falling on the unit
Page 4
HOW IT WORKS
Your Pridiom Desiccant dehumidifier removes moisture using a continu­ously rotating moisture absorbing wheel/rotor (This ‘Desiccant Rotor’ is liter­ally a ‘honeycomb’ of extremely hygroscopic membranes). A highly efficient yet low noise fan draws air into the unit (Process Air) and forces it through a portion of the absorbent rotor. As the air passes through the rotor, the honey­comb, of hygroscopic membranes absorb almost all of the moisture creat­ing an extremely dry airstream, this airstream is discharged directly through the ‘Dry Air Outlet’. A second fan pushes a separate air stream (Regen Air) through a heater bank (Regen Heater) where it’s temperature is raised. This air is then channelled back through a section of the rotor . As this air passes back through the membranes, its higher temperature drives-out the previ­ously absorbed moisture and discharges it as warm wet air through the ‘Wet Air Out’ duct. As the wheel rotates, this process of collecting and discharging moisture is continuous.
DESICCANT ROTOR
The Desiccant Rotor is the heart of the dehumidifier. It is an array of specially absorbent membranes arranged as a series of corrugations (as shown in the cut-away image below) to give a vast surface area making it an extremely efficient moisture collector. It is encases in a galvanized steel ring and turns on high quality sealed ball bearing units.
REGEN HEATER BANK
The PGD970DES uses a ceramic PTC type regen heater. PTC (Positive Temperature Coefficient) heaters are base on a semi-conductor that changes resist- ance as it becomes hotter. The semi-conductor is designed so that it’s resistance rises rapidly at a predesignated temperature, thus it maintains this temperature across a wide range of operational conditions. This characteristic means that the heating element can never over heat to hazardous temperatures, even if the regen airfow is completely blocked.
Page 5
DESICCANT ROTOR
The Desiccant Rotor is the heart of the dehumidifier. It is an array of specially absorbent membranes arranged as a series of corrugations (as shown in the cut-away image below) to give a vast surface area making it an extremely efficient moisture collector. It is encases in a galvanized steel ring and turns on high quality sealed ball bearing units.
REGEN HEATER BANK
The PGD970DES uses a ceramic PTC type regen heater. PTC (Positive Temperature Coefficient) heaters are base on a semi-conductor that changes resist­ance as it becomes hotter. The semi-conductor is designed so that it’s resistance rises rapidly at a predesignated temperature, thus it maintains this temperature across a wide range of operational conditions. This characteristic means that the heating element can never over heat to hazardous temperatures, even if the regen airfow is completely blocked.
Page 6
POSITIONING
The PGD970DES is designed only for indoor use however, it can be placed either inside or outside the room needing to be dried.
Internal
Positioning: When positioning the unit inside the room, place centrally, ensuring inlet and outlet ducts are clear of obstruction. If required, ducts can be connected to the outlet and/or inlet to direct the dry­ing to specific areas. The Wet-Air-Out and Regen-Air-In MUST be ducted to and from outside the room.
External Positioning: When positioning the unit outside the room, connect ducting to the outlet to direct the dry air stream into the room to be dried. The Process-Air-Inlet inlet should also be ducted to the room to give a re-circulation effect.
Note: As the Wet-Air-Out discharge is warm and very humid ensure it is directed where it will have no adverse effect on the immediate environment.
All ducting lengths should be kept to a minimum - longer lengths will reduce performance.
The Wet-Air-Out is warm and humid, when a duct is attached, condensation may form on the inside of the duct. This duct should slope downwards away from the unit to prevent any condensation running back into the unit.
CONTROLS
Controls are positioned on the front of the unit next to the air outlet duct.
Power Switch
Ammeter
Hour Meter
Remote Humidistat Switch
Remote Humidistat Connector
OPERATION
Page 7
OPERATION
Stand-Alone Operation: Connect unit to suitable mains supply Ensure ‘Remote Humidistat’ switch is set to ‘OFF’ position Switch ‘Power’ switch to ‘ON’ ( I ) position. The fan will start and the Ammeter reading will rise. (The ammeter indicates the current taken by the PTC heater bank. Its reading will depend on the ‘Pro­cess’ air temperature and the ‘Regen’ airflow. Typically, it will indicate between 4 and 6 amps - this will reduce if the airflow is low or the Process air tempera­ture is high.
Remote Operation:
For remote operation it is necessary to connect a switch or humidistat via the ‘Remote Humidistat Connector’ - this can be accessed by removing the dust cap. A connection plug is available on request.
ATTENTION - The remote connector is mains voltage! The remote switch/humidistat should be connected between pins 1 and 3. The Earth pin is connected to ground and can be used if required. (see wiring diagram) The ‘Remote Humidistat’ switch should be set to the ‘ON’ position. The unit will now operate according to the state of the remote switch.
Air Filter: Your unit has an inlet air filter that should be checked periodically and if necessary cleaned. It can be cleaned with a vacuum cleaner or washed in mild detergent.
ATTENTION: Do not run the unit without a filter fitted as dust will impair the performance of the Desiccant Rotor.
Page 8
OUTLET DUCT
60 Hz
12.5 A
120 V
8
TECHNICAL DATA
Specifications PGD970DES
Typical Extraction @ 80°F 74 Pt/Day
Air Flow (Process) 14125 ft
3
/hr
Air Flow (Regen) 4414 ft
3
/hr
Voltage
Current @ 80°F
Frequency
Power @ 80°F
1.5kW
Phase 1ph
Dimensions (in)
22.04 x 13.85 x 13.58
Weight (NET) 43.6 lbs
Weight (GROSS) 50.7 lbs
Operating Temperature -4°F – 104°F
Disposal This marking indicates that this product should not be disposed with other house­hold wastes. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources.
Page 9
OUTLET DUCT
REGEN AIR INLET DUCT
PROCESS AIT DUCT
WET AIR OUTLET DUCT
4.92 in
3.15 in
4.92 in
13.85"
13.85"
3.15 in
22.04"
Page 10
10
MAINTENANCE
ATTENTION:
Maintenance should only be carried out by qualified personnel
Unit should be disconnected from mains before removing covers
If unit has just been running, heater bank may still be hot
Desiccant Rotor:
The desiccant rotor is maintenance free however, if it becomes blocked with dust (e.g. if it has been running without inlet air filter) it can cleaned by vacuum cleaner or low pressure compressed air.
Heater Bank:
The PTC heater bank is maintenance free however, if it becomes blocked with dust (e.g. if it has been running without inlet air filter) it can cleaned by vacuum cleaner or low pressure compressed air.
Desiccant Rotor Drive:
The desiccant rotor is driven by a geared motor via a toothed belt. The rotation speed is approximately 48RPH. It can be seen turning during operation through the air outlet duct,
Over-Heat Protector:
In the event of total airflow loss, the over-heat protector will operate. If this happens it will need to be manually re-set after the airflow is restored. To reset, push the red button (R) down.
Page 11
If the dehumidifier does not operate:
• Make sure the unit is plugged in.
• Check the fuse
• Check the remote humidistat setting
• Ensure the humidistat (if fitted) is turned on.
Low Airfow:
• Check inlet air filter
• Check inlet/outlets not obstructed
• Check ductwork (if fitted) is not obstructed
• Check voltage level
• Check fan is working
If the unit is noisy:
• Check fan operation
• Check rotor drive
• Check for loose screws
Low Dehumidifying Effect:
• Check airflows
• Check Amps reading
• Check rotor is turning
Low Amps Reading:
• Check Regen airflow
• Check Over
-Heat Protector
• Check Heater bank
Rotor Not Turning
• Check belt tension
• Check drive-motor operation
• Check rotor alignment
Page 12
WR-001-ULMains Cable (UL)
12 13
SP
ARE PARTS
Description P
art No.
Inlet Air Filter DH01-C024 Inlet Filter Grille DH01-A008 Fan Motor DH01-P010 Fan Motor Capacitor DH01-P014 Regen Fan DH06-P003 Regen Fan Capacitor DH06-P006 Desiccant Rotor DH01-P009 Rotor Drive Belt DH01-P005 Rotor Drive Pulley DH01-P007 Rotor Drive Motor/Gearbox DH01-P006 Heater Bank DH01-A010 Over-Heat Protector DH01-P015
Mains Cable Gland DH01-P017 Mains Switch DH01-P003 Remote Humidistat Switch DH01-P003 Ammeter DH01-P001 Hour Meter DH01-P002 Remote Humidistat Connector DH01-P013 Remote Humidistat Plug DH01-P022
SCHEMA
WIRING DIAGRAM
Page 13
SCHEMA
TIC DIAGRAM
WIRING DIAGRAM
REMOTE
CONNECTOR
L
MAINS
SWITCH
N
M
PROCESS
FAN
M
ROTOR
DRIVE
HEATER
BANK
REMOTE
HUMIDISTAT
SWITCH
1
3
REMOTE SWITCH /
HUMIDISTAT
(OPTIONAL)
FAN CAPACITOR
OVER-HEAT
PROTECTOR
(MANUAL RESET)
AMMETER
HOUR
METER
HOUR
METER
E
E
M
REG. FAN
FAN CAPACITOR
TERMINAL
BLOCK
MAINS LEAD
MAINS
SWITCH
REMOTE
HUMIDISTAT
SWITCH
HOUR
METER
AMMETER
REMOTE
CONNECTOR
1
E
3
2
HEATER
BANK
CAPACITOR
L N E
OHP
ROTOR
DRIVE
BLU BLK BRN G/Y
BLU
BLK
BRN
G/Y
CAPACITOR
REG. FAN
Page 14
Y
Page 15
Y
Page 16
16
201.266.6775
info@pridiom.com
Englewood, NJ 07631
www.pridiom.com