![](/html/69/6997/699777b240f0d4065c4a27da3cf8e5ac5f984f79170f7ef9951ab20a00dc2fcd/bg1.png)
AIR CONDITIONER
REMOTE CONTROLLER ILLUSTRATION
CS406-R51E
202055090357
20100119
Thank you very much for purchasing our air conditioner.
Please read this owner's manual carefully before using
your air conditioner.
![](/html/69/6997/699777b240f0d4065c4a27da3cf8e5ac5f984f79170f7ef9951ab20a00dc2fcd/bg2.png)
CONTENTS
Handling the remote controller ......................................................
Remote controller Specifications...................................................
Function buttons .................. .........................................................
Indicators on LCD ..........................................................................
How to use the buttons .................................................................
Handling the remote controller
Location of the remote controller.
2
3
4
6
8m
SET T
EMPE
AUTO
RATU
COOL
RE( C)
DRY
HEAT
FAN
HIGH
MED
LOW
TEMP
MODE
ON/OFF
SWING
FAN SPEED
ECONOMY
ION
TIMER ON
RESET
LOCK
FO
TIMER
LLOW
ME
OFF
LE
DISP
D
LAY
TURBO
Use the remote controller within a distance of 8
meters from the appliance, pointing it towards the
receiver. Reception is confirmed by a beep.
7
Auto operation.................................................................................
Cooling/Heating/Fan operation......................................................
Dehumidifying operation ...............................................................
Swing operation..............................................................................
Timer operation...............................................................................
ECONOMY operation ....................................................................
12
7
7
CAUTIONS
The air conditioner will not operate if curtains, doors or other materials
8
8
9
block the signals from the remote controller to the indoor unit.
Prevent any liquid from falling into the remote controller. Do not expose
the remote controller to direct sunlight or heat.
If the infrared signal receiver on the indoor unit is exposed to direct
sunlight, the air conditioner may not function properly. Use curtains to
prevent the sunlight from falling on the receiver.
If other electrical appliances react to the remote controller, either move
these appliances or consult your local dealer.
Replacing batteries
The remote controller is powed by two dry
batteries(R03/LR03X2) housed in the rear
part and protected by a cover.
(1) Remove the cover by pressing and sliding off.
(2) Remove the old batteries and insert the new
batteries,placing the(+) and (-) ends correctly.
(3) Reattach the cover by sliding it back into
position.
NOTE: When the batteries are removed, the
remote controller erases all programming.
.
After inserting new batteries, the remote
controller must be reprogrammed.
11
22
![](/html/69/6997/699777b240f0d4065c4a27da3cf8e5ac5f984f79170f7ef9951ab20a00dc2fcd/bg3.png)
CAUTIONS
Do not mix old and new batteries or batteries of a different type.
Do not leave the batteries in the remote controller if it is not going
to be used for 2 or 3 months.
Dispose of the old batteries in the special containers to be found
in the sales outlets.
Remote Controller Specifications
R51I5/BG(C)E, R51I6/BG(C)E,
Model
Rated Voltage
Lowest Voltage of
CPU Emitting Signal
Signal Receiving
Range
Environment
R51I7/BG(C)E, R51I8/BG(C)E,
R51I10/BG(C)E, R51I11/BG(C)E,
R51I9/BG(C)E;
R51I12/BG(C)E;
3.0V(Dry batteries R03/LR03 2)
2.0V
8m (when using 3.0 voltage,
it Gets 11m)
-5 C 60 C( )
~~
OO
-41 F~140 F
NOTE:
Temperature setting display:
Celsius scale( C):
Fahrenheit scale( F):
R51I5/BG(C)E, R51I6/BG(C)E,
R51I9/BG(C)E;
R51I10/BG(C)E, R51I11/BG(C)E,
R51I7/BG(C)E, R51I8/BG(C)E,
R51I12/BG(C)E.
Performance Feature
1. Operating Mode: AUTO, COOL, DRY, HEAT(Cooling only
model without), and FAN.
2. Timer Setting Function in 24 hours.
3. Indoor Setting Temperature Range : 17 C~30 C(62 F~88 F).
OO
4. Full function of LCD (Liquid Crystal Display)
5. Back light emitting.
Function buttons
SET TEMPERATURE( C)
AUTO
COOL
DRY
HEAT
TEMP
1
ON/OFF
3
4
5
MODE
SWING
ION
FOLLOW
ME
ECONOMY
RESET LOCK
LED
DISPLAY
FAN SPEED
TIMER OFF
6
7
Model: R51I5/BG(C)E,
R51I6/BG(C)E,
R51I7/BG(C)E,
R51I8/BG(C)E.
ION and FOLLOW button:
Optional function.
FAN
HIGH
MED
LOW
TIMER ON
TURBO
TEMP UP Button
1
Push this button to increase the indoor temperĀature setting in 1 C(2 F) increments to 30 C(88 F).
TEMP DOWN Button
2
Push this button to decrease the indoor temperĀature setting in 1 C(2 F) increments to 17 C(62 F).
3
MODE Button
oo
oo
Each time the button is pressed, the operation
mode is selected in the sequence of the following:
AUTO
2
NOTE: Heat mode is for Cooling & Heating models only.
8
9
SWING Button
4
10
11
Used to stop or start louver movement and
set the desired up/down airflow direction.
5
ION Button(Optional)
12
When push this button, the ion generator is
13
energized and will help to remove pollen and
14
impurities from the air.
15
6
FOLLOW ME Button(Optional)
COOL
DRY
HEAT FAN
Push this button to initiate the Follow Me
function, the remote controller begins to detect
the actual temperature at its location. The
remote controller will send this signal to the
air conditioner every 3 minutes interval until
press the Follow Me button again. The air
conditioner will beep to indicate the Follow Me
feature has ended if it does not receive the
signal during any 7 minutes interval.
RESET Button
7
Once the recessed RESET button is pressed,
all of the current settings will be cancelled
and the controller will return to the initial settings.
ON/OFF Button
8
Operation starts when this button is pressed
and stops when the button is pressed again.
9
FAN SPEED Button
Used to select the fan speed in four steps:
Auto Low Med High
10
TIMER ON Button
Press this button to activate the Auto-on time
setting. Each press will increase the time setting
33 44