Pridiom AWS120HR, AWS180HR, AWS240HR, AOS090HR, AOS120HR Installation Manual

...
Page 1
Installation manual
www.pridiom.com
www.Thermospace.com
Page 2
Air conditioners are units that should have the professional technicians do the
installation for you. This Instruction Guide is the universal-purpose version for the models of split wall-mounted air conditioners manufactured by our Co. The appearance of the
units that you purchase might be slightly different from the ones described in the Guide, but it does not affect your proper operations and usage.
Please read carefully the sections corresponding to the specific model you choose, and keep the Guide properly so as to facilitate your reference at later time.
Selection of installation positions for indoor unit Selection of installation positions for outdoor unit Installation fixture of indoor unit Installation fixture of outdoor unit Installation of electric components Pipelines connection Air purging Connection of power cable Finishing touches and test running Is the unit installed correctly? Self diagnosis functions Wire diagram
www.Thermospace.com
Page 3
1
*
Selection of installation positions for indoor unit
*
* To be installed at the position where the air delivered from the unit can reach every corner of
the room;
* To avoid being affected by the outdoor air; * To avoid blockage to the air inlet or outlet of the unit; * To avoid too much oil smoke or steam; * To avoid possible generation, inflow, lingering or leakage of flammable gases; * To avoid high-frequency facilities (such as high frequency arc welders, etc.); * To avoid the places where acid solutions are frequently used; * To avoid the places where some special sprayers (sulfides) are frequently used. * Not to install a fire alarming device near the air outlet of the unit (during operation, the fire alarm
device might be erroneously triggered by the warm air from the unit);
Above 100mm(4")
Left side: 150mm(6") and above
Right side: 150mm (6") and above
Ceiling
Wall hanging plate
ground
2300mm(7'6") and above
*
Make sure of enough space for installation and maintenance.
* To take into consideration the operational convenience and safety in installation, it is recommended
to ensure enough space between the unit and the walls.
*
Height limits of indoor and outdoor units.
* Either the indoor unit or the outdoor unit can be higher, but the height difference must comply the stated
requirements.
* Try to reduce the bending of the piping line as much as possible so as to avoid possible negative impacts upon the
performances of the units.
Indoor unit
outdoor unit
5m(16'5")max.
INSTALLATION & REPAIR GUIDE
Split Wall-Mounted Air Conditioner
www.Thermospace.com
Page 4
2
*
Selection of installation positions for outdoor unit
*
* To install the outdoor unit at the places which can stand the load of the machine weight and will
not cause big vibrations and noises;
* To install the unit at the places not to be exposed to rain or direct sunshine, and the places with
good ventilation;
* The noises generated from the unit will not affect the neighboring places; * Do not install the unit on non-metal frame; * Not to install the unit at the places where there might occur the generation, inflow, stay or
leakage of inflammable gases;
* Pay attention to the drainage of the condensed water from the base plate during operations; * To avoid the air outlet being directly against the wind.
Detailed space requirements around the outdoor unit
1. When there are obstacles above the unit
2. When the front (air outlet) is open 3. When there are obstacles only in the front (air outlet)
4. When there are obstacles at the front and rear sides.
5. When there are obstacles all around the unit on four sides. Although the top side is open, the installation is not to be done if there are obstacles all around.
Space for maintenance
Shown as in the following figure. Keep the maintenance space in front of the unit.
500mm(1'8") min
100mm(4") min
500mm(1'8") min
200mm(8") min
500mm(1'8") min
500mm (1'8")min
200mm (8")min
Space for maintenance
* At least two sides should
be kept open.
200mm(8") min
300mm(1') min
1000mm(3'4") min
100mm(4") min
INSTALLATION & REPAIR GUIDE
Split Wall-Mounted air conditioner
www.Thermospace.com
Page 5
3
*
Installation fixture of indoor unit
*
INSTALLATION & REPAIR GUIDE
Split Wall-Mounted air conditioner
1.Installation of wall-mounting plate
Fix the wall-mounting plate firmly on the wall with screws. Make sure of the leveling of the plate. Slanted wall-mounting plate might jeopardize the smooth discharge of the condensed water.
2.Drill holes on the wall
3.Installation of drain pipe
Install the pipelines of the indoor unit in accordance with the direction of the wall holes. Wrap tightly the drain pipe and the pipelines with tape. Make sure that the drain pipe is underneath the pipelines. (Fig.3) (When the drain pipe passes the room interior, some condensed water might occur to its surfaces if the humidity is very high).
4.Installation of indoor unit
Pass the connection wires, connecting pipelines and drain pipe through the wall hole. Hang the indoor unit on the hooks at the top of the wall-mounting plate so that the hooks at the bottom of the indoor unit match the hooks of the wall-mounting plate. (Fig.4)
Fig.2
Fix with a tape
Wall cap
Wall pipe
Interior
Exterior
5-10mm lower (1/5-2/5")
Wall
Fig.3
Pipelines of indoor unit
Drain pipe
Rear pipe
Bottom hooks
Hook supports
Top hooks
Fig.4
Drill holes at places slightly below the wall-mounting plate, with hole diameter of 65mm(2-3/5") and the outer edge of the hole 5-10mm(1/5-2/5") lower (Fig.2) so that the condensed water can smoothly flow out. Cut the wall penetrating pipe to proper length according to the thickness of the wall (3­5mm(1/10-1/5") longer than the wall thickness) and insert the pipe as indicated in Fig.2.
www.Thermospace.com
Page 6
4
*
Installation fixture of outdoor unit
*
Inspections:
a. Check if the hooks at the top and bottom are firmly fixed. b. Check if the position of the master unit is properly leveled. c. The drain pipe should not curve upward (Fig.5). d. The drain pipe should be at the lower part of the wall pipes (Fig. 5).
Drain pipe
Connecting wires
Connecting pipe
Wall pipe
Drain pipe
Fig.5
* Try to ship the product to the installation location in its original package; * As the gravity center of the unit is not at the installation center, special caution should be taken
when using hoisting cables to lift it up;
* During shipping, the outdoor unit must not be slanted to over 45 degrees (Do not store the unit
in a horizontal way).
* Use expansion bolts to fix the mounting supports on the wall; * Use bolts and nuts to fix the outdoor unit firmly on the supports and keep on the same level; * If the unit is installed on the wall or at the rooftop, the supports have to be firmly fixed so as to
resist earthquake or strong wind.
Dimensions for parallel units installations
300mm(1')min
INSTALLATION & REPAIR GUIDE
Split Wall-Mounted air conditioner
www.Thermospace.com
Page 7
AWOS090HR/120HR MODEL
AWOS090HR/120HR MODEL:
AWOS180HR/240HR MODEL
www.Thermospace.com
Page 8
INSTALLATION & REPAIR GUIDE
Split Wall-Mounted air conditioner
www.Thermospace.com
Page 9
Tightening torque
6.35(1/4")
9.52(3/8")
12.7(1/2")
15.88(5/8")
19.05(3/4")
Table 1
Torque based upon the wrench to be used
Strengthened tightening torque
160kgf.cm(63kgf.inch)
300kgf.cm(118kgf.inch)
500kgf.cm(197kgf.inch)
750kgf.cm(295kgf.inch)
1200kgf.cm(472kgf.inch)
200kgf.cm(79kgf.inch)
350kgf.cm(138kgf.inch)
550kgf.cm(216kgf.inch)
800kgf.cm(315kgf.inch)
1400kgf.cm(551kgf.inch)
*
Pipelines connection
*
*
Ordinary pipelines connection
(it is suitable for non-quick coupler)
No dust ,foreign articles,air or moisture should be allowed to enter the air conditioning system.Careful attention should be paid when pipeline connection for outdoor unit is made.Try to avoid repeated curves as much as possible,otherwise hardening or cracks might be caused to the copper pipes.Suitable wrenches should be used when the pipeline connection is done so as to ensure appropriate torque(refer to following torque Table 1).Excessive torque might damage the joints while too little torque might lead to leakage.
INSTALLATION & REPAIR GUIDE
Split Wall-Mounted Air Conditioner
7
www.Thermospace.com
Page 10
Air Purging
Air purging With Vacuum Pump
8
www.Thermospace.com
Page 11
-
Soap water method
(1)
Remove the caps from the gas side and liquid side valves.
(2)
Remove the service-port cap from the gas side valve.
(3) To open the gas side valve turn the valve
stem counterclockwise approximately
90°,
wait for about 2-3 seconds, and close it.
(4)
Apply a soap water or a liquid neutral detergent on the indoor unit connection or outdoor unit connections by a soft brush to check for leakage of the connecting points of the piping.
(5)
If bubbles come out, the pipes have
leakage.
Evacuation
Outdoor
unit
Connect the charge hose end described in the preceding steps to the vacuum pump to evacuate the tubing and indoor unit. Confirm the "Lo" knob of the manifold valve is open. Then, run the vacuum pump. The operation time for evacuation varies with tubing length and capacity of the pump. The following table shows the time required for evacuation.
vacuum pump is used
When the desired vacuum is reached, close the
"Lo" knob of the manifold valve and stop the
vacuum pump.
Adding refrigerant
Refrigerant must be added if the piping measures more than 7.5 metres(%") in length.This operation can only be performed by a professional technician,for the additional
amount,see the table 3 below.
Vacuum pump
Fig.
6
Table
3
(piping length-7.5)mx30g (piping length-7.5)mx65g
www.Thermospace.com
Page 12
10
www.Thermospace.com
Page 13
11
*
Connection of power cable
*
INSTALLATION & REPAIR GUIDE
Split Wall-Mounted air conditioner
1.Remove the drawer of the outdoor unit.
2.Connect the indoor power and control wires with the matched outdoor wires in accordance with the electric schematic diagram and make sure that the connection is firmly done(Fig.7)
wire pressing plate
Drawer
screw
3.Use a press plate to fix the wires firmly,and re-install the drawer.
Note:Do not connect the wires in a wrong way,otherwise electric malfunctions will be caused and even damages to the units will occur.The appliance shall be installed in accordance with national wiring regulation.If the supply cord is damaged,it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.The plug shall be accessible after installing the appliance.If the model have not plug that a switch which have a contact separation of at least 3 mm(1/10") in all poles shalled be added in fixed wiring.
* Use thermal tube to wrap the joints and wrap the tube tightly with ethylene tapes. * Fix the wrapped pipelines on the exterior wall with clamps. * Fill in the gaps left over by the pipeline hole and wall hole to prevent rain-water from entering.
*
Finishing touches
*
* Connect to the power source,check if the function selection keys on the remote controller are
working properly.
* Check if the room temperature adjustments and timer settings are working properly. * Check if the drain is smooth. * Check if there is any abnormal noise or vibration during operation. * Check if there is leakage of refrigerant.
*
Test running
*
Fig.7
*
Is the unit installed correctly?
*
*
Isn't there anything which prevents ventilation or obstructs operation in front of the indoor unit ?
Do not install the unit following place .
*
Inflammable gases may leak .
*
Oil splashes a lot .
*
In case where the unit is used in such places as poisonous or sultry gases are generated or seaside
district exposed to sea breezes corrosion may cause malfunction . Consult with your distributor .
*
Air conditioner body and remote controller must be I m(39-3/4") or more away from a TV or a radio.
Drain the dehumidified water from the indoor unit to a place which drains well .
*
When installing the unit , choose a place which can stand the weight of the unit well and does not increase the operation noise or vibration . Especially where there is a possibility that vibration be transmitted to the house , fix the unit by inserting attached vibration -proof pads between the unit and fittings .
*
Suitable Installation Position
*
Pay attention to operation noise
www.Thermospace.com
Page 14
*Self Diagnosis Functions*
Our company provides the thoughtful services for customer,air conditioners had been
installed self diagnosis system to display the information for the units.
INSTALLATION & REPAIR GUIDE
Split Wall-Mounted air conditioner
12
*
According to the service conditions and operating environment , the inside of the air conditioner will become dirty after several seasons (3 to 5years ) of service , resulting in decreased operating performance .Inspection and maintenance are recommended in addition to usual cleaning (The air conditioner can be used for a longer period and without anxiety .)
*
As to inspection and maintenance , consult your dealer or any one of business offices of dealing companies .(Service charge is required in this case .)
*
We recommend to perform inspection and maintenance during an off seasons.
*
Choose the place where hot air and operation noise from the outlet of the outdoor unit do not annoy the neighborhood .
*
Things left near the outlet and inlet of the outdoor unit cause malfunction or increased operation noise . Do not leave obstacles near the outlet and inlet .
*
If irregular sound is heard during operation , consult with your distributor .
*
Inspection and Maintenance
Note:Above self check information is commonly applicable in our most air conditioners,but some are special,you can refer to the User's Manual for information or contact the dealer or authorized maintenance people for help.
Digital self-check code/ (Polychrome screen self-check code)
Hint to defrosting
Flicker 1 time/1s
Hint to defense against cold wind
Flicker 1 time/3s
Failure of room temperature sensor
Failure of coiled pipe sensor
Abnormality of outdoor unit
Without feedback of internal fan motor
Zero crossing signal without current
External feedback failure
Overheat protection
Water pump failure
Self-check code of luminotron/ (Self-check code of running lamp)
Flicker 2 times/4s (Flicker 2 times/8s)
Flicker 3 times/5s (Flicker 1 time/8s)
Flicker 4 times/6s (luminating)
Flicker 5 times/7s (Flicker 6 times/8s)
Flicker 6 times/8s
Flicker 7 times/9s
Flicker 8 times/10s
Flicker 9 times/11s
Self-check information
Indicates "dF"or defrosting indicator displays
Fan motor picture not running
E2/(L2)
E3/(L1)
E4/(E5)
E5/(L6)
E7
E6
E8
E9
www.Thermospace.com
Page 15
13
*
Selection of installation positions for outdoor unit
*
* To install the outdoor unit at the places which can stand the load of the machine weight and will
not cause big vibrations and noises;
* To install the unit at the places not to be exposed to rain or direct sunshine, and the places with
good ventilation;
* The noises generated from the unit will not affect the neighboring places; * Do not install the unit on non-metal frame; * Not to install the unit at the places where there might occur the generation, inflow, stay or
leakage of inflammable gases;
* Pay attention to the drainage of the condensed water from the base plate during operations; * To avoid the air outlet being directly against the wind.
Detailed space requirements around the outdoor unit
1. When there are obstacles above the unit
2. When the front (air outlet) is open 3. When there are obstacles only in the front (air outlet)
4. When there are obstacles at the front and rear sides.
5. When there are obstacles all around the unit on four sides. Although the top side is open, the installation is not to be done if there are obstacles all around.
Space for maintenance
Shown as in the following figure. Keep the maintenance space in front of the unit.
500mm(1'8") min
100mm(4") min
500mm(1'8") min
200mm(8") min
500mm(1'8") min
500mm (1'8")min
200mm (8")min
Space for maintenance
* At least two sides should
be kept open.
200mm(8") min
300mm(1') min
1000mm(3'4") min
100mm(4") min
INSTALLATION & REPAIR GUIDE
Split Wall-Mounted Air Conditioner
www.Thermospace.com
Page 16
AOS090HR&120HR outdoor wire diagram
AWS090HR indoor wire diagram:
14
www.Thermospace.com
Page 17
AWS120HR indoor wire diagram:
AOS180HR outdoor wire diagram
15
www.Thermospace.com
Page 18
AOS240HR outdoor wire diagram
B L
AWS180HR&240HR indoor wire diagram
16
www.Thermospace.com