DALI Touch ME7
preussen automation GmbH © 2016 | Flurweg 11 | 82402 Seeshaupt | service@preussen-automation.eu
Contents
Description of the DALI Touch ME7 panel 4
Assembly 5
Initialization screen 6
Pre-set dynamic sequences 8
Custom dynamic sequences 9
Static pre-sets
11
The settings
12

preussen automation GmbH © 2016 | Flurweg 11 | 82402 Seeshaupt | Germany
DALI Touch ME7
Description of the DALI Touch ME7 panel
A The connector for connecting the
data network.
B The feeding connector.
C 3 x DALI line (the most upper one is
internally biased).
D Reserved for future use.
Earthing
The opening for connecting
Make the opening by removing one of
the indicated parts.
Fixing on the wall
Bend the indicated parts in the
direction outside from the corpus.
Screw on the reverse side of assembly
corpus.
4
A
B
-
+
D
C

www.preussen-automation.eu | service@preussen-automation.eu
Assembly on the solid wall
228 mm
80 mm
155 mm
3
2
1
Assembly (Plasterboard, OSB plate, etc.)
min.
90 mm
4- 45 mm
228 mm
155 mm
1
2
2
2
3
4
Assembly
5

preussen automation GmbH © 2016 | Flurweg 11 | 82402 Seeshaupt | Germany
DALI Touch ME7
Initialization screen
After the first power-on you have to
choose the mode of DALI Touch ME7
panel. You can choose either Tunable
White mode (TW mode) or RGB mode.
Furthermore you can choose whether
you would like to use the ambient light
sensor (closed loop) or not (open loop).
Select the DALI line you would like to
use. Multiple DALI lines can be selected.
Only DALI line 1 is internally biased. DALI
lines 2 and 3 needs external DALI power
supply.
Screen for addressing the ballast
depends on the mode selection – TW
or RGB. Press SCAN to start searching
process. All DALI devices present on
the DALI bus will appear the column on
the left with their corresponding DALI
addresses. Press the address to select
TW mode
TW control without sensor
TW control with sensor
RGB control
the DALI device. To identify DALI device
you use button IDENTIFY – DALI device
starts to periodically turn the light
on and off. Identification is aborted
by repeated press of the button. To
move DALI device into the groups for
TW or RGB control use corresponding
buttons: ”warm / cold” for TW mode or
”red / green / blue” for RGB mode. The
selected DALI device then appears in the
corresponding column. Use arrows up
and down to scroll the columns. Whole
group of devices can be identified using
corresponding TEST button. To remove
DALI device from a group use trash
button. The deleted device will appear
back in the left column. After finishing
the selection of DALI devices into the
groups press OK.
6
Use trash button to remove
the device from group.
Use OK button to finish and
save the settings.

www.preussen-automation.eu | service@preussen-automation.eu
7
RGB Mode
Identifies selected device.
Column with discovered devices.
Press corresponding button to
move the device into correct group.
Starts scanning the DALI lines.
DALI Touch ME7 panel is
scanning the lines.
Home screen offers four basic options. User can choose between ”pre-set”, ”custom
dynamic sequences”, ”static preset” and manual control. Information panel at the
bottom of the screen informs about currently set mode and actual brightness level. In
the bottom-left corner home button is located – pressing home button returns device
to home screen. Use ”settings” button to change settings of DALI Touch ME7.
Manual control mode offers direct control over the DALI luminaires. In TW mode user
can control intensity and colour temperature of luminaires. In RGB mode user can
control hue, saturation and intensity. Control is performed when touching and moving
the scroll button of the corresponding slider. Return to the home screen can be done
using ”x” button or by using home button.
RGB control Information panel
Manual
control

preussen automation GmbH © 2016 | Flurweg 11 | 82402 Seeshaupt | Germany
DALI Touch ME7
8
Pre-set dynamic sequences
When selecting ”pre-set dynamic se-
quences” in TW mode user will see three
dynamic white pre-sets:
”daylight”, ”activate” and ”moving”.
By pressing the buttons corresponding
pre-set sequences will be selected and
sequence timing screen will appear.
Parameters of dynamic sequence can
be set after selection of the sequence.
Repetition of the sequence can be
enabled or disabled and number of
repetition can be set. The user can
also define whether the light should be
turned off after the end of sequence
or not. The sequence starts after
confirmation by pressing OK button. The
activated sequence is indicated in the
information bar as well as with the play
sign placed on the corresponding preset button. The sequence will be active
until other sequence or scene is set or
manual control is used. In RGB mode
there are eight pre-set options. Timing
settings looks the same as for TW mode.
Activated sequence.

www.preussen-automation.eu | service@preussen-automation.eu
9
Custom dynamic sequences
When selecting ”custom dynamic
sequences” in any mode a dialog for
setting, editing and creating custom
dynamic sequences will appear. On the
left side of the screen button for loading
existing custom dynamic sequences are
located. If password protection is set
you have to press ”unlock tools” and
type password first in order to add or
modify sequences. Security settings are
located in settings menu. On the right
side of the screen buttons for custom
sequences management are placed. You
can add new sequence by pressing ”add
new” button or edit the existing custom
sequence by pressing ”edit” button.
”duplicate” button serves for creating
a copy of existing sequence. ”modify
preset” button allows for modification
of pre-set sequence and saving it as
custom sequence. Undesired sequences
can be remove using button ”delete”.
Use touch keyboard to enter the label.
When adding new sequence you will
be prompted to enter a label for new
sequence.
Colour definition
Add / remove
point on timeline
Go to defined time
Previews the
sequence
Sequence
overview
Zoom / Unzoom overview

preussen automation GmbH © 2016 | Flurweg 11 | 82402 Seeshaupt | Germany
DALI Touch ME7
Colour definition in RGB (on the left) and TW (on the right) mode.
When pressing SAVE button new dynamic sequence is saved and appears on the left
side of the screen. By clicking on the sequence button the sequence is selected and
timing settings screen appears. Selected sequence is indicated also in the Information
panel.
10

www.preussen-automation.eu | service@preussen-automation.eu
11
Static pre-sets
Static pre-sets offer static RGB or TW scenes. The possibilities for their adding
and modification are the same as for the dynamic sequences. Preview of currently
set scene can be seen in the preview corner on the upperright part of the screen.
Currently selected static pre-set is also indicated on the Information panel.

preussen automation GmbH © 2016 | Flurweg 11 | 82402 Seeshaupt | Germany
DALI Touch ME7
12
The settings
The settings menu offers several modifications and settings. First option is for
date and time setting.
The user can setup current time, date
and also time zone for faster time
settings. The settings are saved and
restart of the device is needed.
Language settings offer modifications
for English, Slovak and German.Change
of the language also needs restart of the
device.
Screen and screensavers options offer
possibility turning off the screen after
some period of time or to start a
slideshow of screensaver pictures.
The user can choose the picture for
slideshow and time between the
pictures. The pictures can be uploaded
via web interface.

www.preussen-automation.eu | service@preussen-automation.eu
Display cleaner disables the sensitivity
of touch panel for 10 seconds in order to
enable its cleaning without affecting the
settings of the panel.
System modification and new system
initialization button reloads the initialization screen and allows for modification of DALI device addressing or
completely new initialization of the
system.
Security settings allows for activation
or deactivation of password protection
for modification of settings. The user
can set up password that contains four
numbers (PIN code).
The network setting are needed for
connection through the Ethernet. It is
necessary to set IP address of the DALI
Touch ME7 panel. You can use DHCP
panel if there is DHCP server connected
to the panel. If not static IP address has
to be used. User can type any IP address.
13

preussen automation GmbH © 2016 | Flurweg 11 | 82402 Seeshaupt | service@preussen-automation.eu
DALI Touch ME7
14
When touch the arrows in the right part
of the screen you can scroll to the last
two buttons that deals with the timing
configuration of movement sensor and
the calibration of light sensor. These
settigns are valid only for closed loop
TW mode with correctly connected light
and movement sensor ”MSensor2” by
Tridonic. Calibration and settings of the
sensor will be further described in final
user guide.
The calibration of ambient sensor
In the sensor calibration screen you will
see one row for each sensor that was
found on the DALI bus. The first number
is the address of the sensor. When
user presses the first input textbox
the brightness level will be set to 33 %
by broadcast. Now the user should
measure illuminance using the luxmeter
and type the illuminance value in lx into
the textbox. The situation repeats for
the next two textboxes with 66 % and
100 % brightness levels. After entering
the reference illuminance levels the
calibration is confirmed by pressing OK
button.