Pressure Tech LF-301 SERIES Operating And Service Manual

1
THE LF-301 SERIES
Operating and Service Manual
Issue B
January 2016
2
TABLE OF CONTENTS
1. Description ............................................................................................................................. 3
2. Installation ............................................................................................................................. 3
3. Operation ............................................................................................................................... 4
4. Special Conditions for Safe Use ............................................................................................. 4
5. Hazardous Location Usage ..................................................................................................... 4
6. Servicing and Maintenance .................................................................................................... 4
6.1. Servicing the LF-301 ................................................................................................ 5
6.1.1. Accessing the Main Valve Assembly ........................................................ 5
6.1.2. Adjusting the Set Point ............................................................................ 6
6.1.3. Figure 1 – Sectional View of the LF-301 ................................................... 7
7. Technical Data ........................................................................................................................ 8
8. Warranty Statement .............................................................................................................. 8
Annex A. LF-310/311 – ‘Solid Disk’ Main Valve Design ............................................................. 9
A.1. Description.............................................................................................................. 9
A.2. Servicing .................................................................................................................. 9
A.2.1. Figure 2 – Detail A: LF-310/311 ‘Solid Disk’ MVA (sectional) .................. 9
A.2.2. Figure 3 – Exploded View of LF-310/311 ‘Solid Disk’ MVA ..................... 9
3
1. Description
The LF-301 provides a compact and economical solution for controlling pressures up to 180bar on low flow applications. Ideal for first stage pressure let down where basic pressure control is required. A small piston sensing element allows low torque adjustment with a range of springs with fine pressure adjustment. The unique soft seat design ensures particles flow over its surface, rather than perpendicular to it, which helps minimise damage from potential particles in the system.
Pressure Equipment Directive (PED) 2014/68/EC Declaration This equipment is designed and manufactured in accordance with Sound Engineering Practice (SEP) Article 4, Paragraph 3 of the directive 2014/68/EC. As such, CE marking must not be applied. The equipment is marked under section 3.3 of Essential Safety Requirements of the directive.
2. Installation
Before system start-up, it is recommended that all systems be pressure tested, leak tested and purged with an inert gas such as nitrogen.
Prior to placing into service ensure that the regulator is in the fully closed position, with the adjusting mechanism turned completely anti-clockwise.
Check the model number reference to ensure that the pressure range complies with the installation requirements.
Visually inspect the regulator for any signs of damage or contamination. If any foreign materials are present and cannot be removed from the regulator, or if the threads on the regulator appear to be damaged, please contact the office immediately to arrange for the regulator to be returned for service.
The Inlet and Outlet ports are clearly marked. Select the correct size and type of connection fittings for these ports which are indicated in the regulators part number. Both British
Standard Pipe (BSPP) ‘B’ and National Pipe Thread (NPT) ‘N’ options are available on this
regulator. Use the correct dowty or bonded seal for BSPP connections, self centering seals are recommended. For NPT threads, ensure that PTFE tape is applied correctly to the fittings, applying two overlapping layers in the direction of the thread, taking care that the tape does not come into contact with the first thread. Any gauge ports on the regulator will
be 1/4” NPT unless otherwise stated. If any gauge port is not required, ensure that the port
is plugged prior to installation.
The media supplied to the regulator must be clean. Contamination can damage the seat which may cause the regulator to fail. Filtration suited to the application is recommended upstream of the regulator. Should further assistance or information be required in relation to installation of any Pressure Tech regulator please contact the office, giving reference to the regulators part number and/or serial number.
Loading...
+ 6 hidden pages