PRESIDIUM PGCG User Handbook Manual

1
2
Language Contents
1. English Language pg. 03
2. Chinese Language pg. 35
3. French Language pg. 66
6. Russian Language pg. 176
7. Spanish Language pg. 221
3
Contents
(English Version)
I. Disclaimers, Exclusions and Limitations of Liability pg. 04
II. About this book pg. 05
III. About your Presidium Gem Computer Gauge pg. 06
IV. IMPORTANT NOTICE pg. 10
1. GETTING STARTED with your Presidium Gem Computer Gauge pg. 12
2. PERFORMING A TEST with your Presidium Gem Computer Gauge pg. 13
a. Measurement b. Weight Estimator c. S.G. Dictionary d. Gemstone Estimator e. Calculator f. Inventory g. PC connectivity
3. READING TEST RESULTS with your Presidium Gem Computer Gauge pg. 32
4. TAKING CARE of your Presidium Gem Computer Gauge pg. 34
4
PLEASE READ AND NOTE PRESIDIUM WARRANTY TERMS AND CONDITIONS as stated in the warranty card. Presidium warranty for its testers are subject to proper use by its users in accordance with all the terms and conditions as stated in the relevant user handbook and shall cover only manufacturing defects.
Due to continuous product improvement, Presidium reserves the right to revise all documents including the right to make changes to the handbook without notice and without obligation to notify any person of such revisions or changes. Users are advised to check Presidium’s website http://www.presidium.com.sg/ from time to time.
Presidium shall not be responsible for any damage or loss resulting from the use of this gauge or handbook, and under no circumstances shall Presidium, its manufacturer or any of its subsidiaries, licensors, distributors, resellers, servants and/or agents be liable for any direct or indirect damages, resulting from the use of this gauge.
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, under no circumstances shall Presidium, its manufacturer or any of its subsidiaries, licensors, distributors, resellers, servants and/or agents be responsible for any special, incidental, consequential or indirect damages howsoever caused.
The gauge or Presidium Gem Computer Gauge (PGCG) referred to in this handbook is provided and/or sold on an “as is” basis. Except as required by applicable law, no warranties of any kind, either expressed or implied, including, but not limited to, the implied warranties of
merchantability and tness for a particular purpose.
I. Disclaimers, Exclusions and Limitations of Liability
5
II. About this book
Thank you for purchasing the Presidium Gem Computer Gauge (“PGCG” or “gauge”).
This handbook is designed to help you set up your gauge and describes all you need to know about how to use your gauge accurately and take care of it in line with its requirements. Please read these instructions carefully and keep them handy for future reference.
This book also contains the terms and conditions in relation to the use of the gauge including the
Disclaimer, Exclusion and Limitation of Liability clauses stated above in Section I.
6
The Presidium Gem Computer Gauge has been developed as an extension to the existing Presidium Electronic Gemstone Gauge with additional features to perform more functions, including:
• Measures actual gemstone dimensions and
estimates gemstone weight and identity
• Measures 74 gemstones and 9 different shapes
• Accurate measurement up to 0.01mm
• Direct carat conversion for round brilliant cut
diamonds
• Clear and visible display for ease of reading
measurements
• Light and portable instrument that can be used
anywhere
• PC connectivity for ease of importing and printing
measurement results
Product specications:
Measurement range: 0.00mm to 25.00mm or 0.000ct to
57.343ct Recommended battery: CR 2450 3V or equivalent Battery lifespan: generally about 26 hours of continuous usage
Included in your package:
• Presidium Gem Computer Gauge
• CR-2450 3V battery
• High setting jewelry attachment
• Mini CD ROM
• USB Cable
• User handbook
• Warranty card
• Protective box
IIl. About your Presidium Gem Computer Gauge
7
1 LCD Display
2 Base Anvil
3 Wedge-shaped Points
4 Slider
5 Slider Platform
6 Protruding Probe
7 Jewelry Attachment
8 Battery Compartment
9 USB Cable
10 USB Port
11 Selection Keypad
12 Mode Button
13 Clear Button
14 Enter Button
15 Navigation Button
16 Calculator Activation Button
17 Unit Conversion Button
Gauge parts
8
Display Conguration
The LCD display of PGCG is generally divided into three sections.
1. Interactive display
2. Scroll bar
3. Instruction bar
Keypad Conguration
Please refer to table below for the function of each key on the selection keypad. Some keys will have more than one function.
Front View
9
Name Normal Function Additional
Function
1 Carat
mm
Press to change measurement unit between millimeter (mm) and carat (Ct)
In “Weight Estimator” and “Stone Estimator” mode, press to toggle between “Measure­ment” and “Keypad” to input dimension
2 Mode Press to display the
function selection menu
3 Cancel Press to delete
items
• Press to
turn on PGCG
• In ‘Mea
surement” mode, press for tare/ zero function
4 Calcula-
tor
Press to activate calculator mode
In “Weight Estimator” mode, press for price calculation
5 Enter Press to conrm
selection
6 Naviga-
tion keypad
Press to navigate data in interactive display
10
• Keep the gauge dry. Precipitation and all types of
liquids or moisture can contain minerals that will corrode electronic circuits. If your tester does get wet, remove the battery, and allow the tester to dry completely before replacing it.
• Do not use, store or expose the gauge in dusty and
dirty areas. Its moving parts and electronic components can be damaged.
• Do not use, store or expose the gauge in hot areas.
High temperatures can damage or shorten the life of tester, damage batteries, and warp or melt certain plastics.
• Do not use, store or expose the gauge in cold areas.
When the tester returns to its normal temperature, moisture can form inside the tester and damage electronic circuit boards.
• Do not attempt to open the gauge other than as
instructed in this handbook.
• Do not drop, knock, or shake the gauge. Rough handling might break internal circuit boards and ne
mechanics.
• Do not use harsh chemicals, cleaning solvents, or
strong detergents to clean the gauge.
• Do not paint the gauge. Paint can clog the moving
parts and prevent proper operation.
IV. IMPORTANT NOTICE
11
If the gauge is not working properly, kindly contact Presidium Customer Service at service@presidium.com. sg or:
Presidium Instruments Pte Ltd No. 6 Penjuru Lane Singapore 609187 Singapore (65) 6379 5000 Attn: Customer Service Executive
12
1. Pull the battery slider sideway outward using either
ngernail or screw driver.
2. Place a CR 2450 3V battery with the (+) sign facing upward in the battery compartment and close by pushing the battery slider sideway inward.
3. The use of alkaline batteries is preferred, as it should generally give approximately two and a half hours of continuous operation, while the use of ordinary batteries will give a shorter working life.
Turning on your Presidium Gem Computer Gauge
1. Press the “C” button on the selection keypad.
2. The word “Presidium” will appear and the device will automatically go to “Measurement” mode.
3. The screen will display two lines; the rst being
measurement in millimeter unit and the second line being measurement in carat unit.
Please note that the PGCG will automatically shut down after 5 minutes of inactivity.
Battery information
Do not leave worn out batteries in the battery compartment as the batteries may corrode, leak or damage the gauge. Batteries should be removed when the instrument is expected to be stored for an extended period of time.
1. GETTING STARTED with your Presidium Gem Computer Gauge
Inserting a battery into your Presidium Gem Computer Gauge
13
1. By default, upon power up, the device will be in “Measurement” mode.
2. PGCG comes with the following functions: a) Measurement b) Weight Estimator c) S.G. Dictionary d) Gemstone Estimator e) Calculator f) Inventory g) PC connectivity
3. To use other functions, press “Mode” on the selection keypad and choose a function from the list.
a. Measurement
2. PERFORMING A TEST with your Presidium Gem Computer Gauge
Requirement Activation Key Display
1 Upon turning on,
PGCG will dis­play dimension in mm and weight in Carat:
1. Press “C” to turn on
0.00 mm
0.000 ct
2 For display of
dimension in mm only:
1. Press “Ct/ mm”
0.00 mm
3 For display of
weight in Carat only:
1. Press “Ct/ mm”
0.000 ct
14
• The Presidium Gem Computer Gauge should be held
in the palm of either hand. Control the slider with the thumb.
• When measuring loose stones, pull the Slider and
place the stone on the Slider platform. The base of the stone should be parallel to the platform to prevent it from moving.
• When measuring mounted stones, insert the jewelry
attachment to the gauge and place the stone between the jewelry attachment and slider anvil.
15
• Press “ct/mm” to alternate between the following
displays:
1. Display of both dimension in mm and weight in carat (by default)
2. Display of dimension in mm only
3. Display of weight in carat only
The default setting of Presidium Gem Computer Gauge (PGCG) is programmed for American Standard Round Brilliant Cut
For other gemstones of other shapes, please directly proceed to the following steps.
b. Weight Estimator
Presidium Gem Computer Gauge (PGCG) estimates the weight of the gemstone from the shape, diameter, depth and nature of the gemstone.
The different shapes of gemstones as shown in diagram below:
• Slowly close the Slider. The reading will be displayed
on the window immediately.
16
Requirement Activation
Key
Display
1. Select Weight Estimator: Select Mode
Scroll to Weight Estimator
Press “ENT” to
conrm
2. Select New or Previous Set ting: Scroll to select
Press “ENT” to
conrm
[SELECT SETTING]
New Setting
Previous Setting
Round
Marquise
Cushion
Oval
Heart
Square
Emerald
Pear
Cabochon
[MODE]
Measurement
Weight Estimator
S.G. Dictionary
17
3.1 New Settings
Select Gem stone name:
Scroll to select gemstone name by the
rst alphabet.
Press “ENT” to
conrm
Select a Gem stone:
Scroll to select
Press “ENT” to
conrm
Select a Shape: Scroll to select
Press “ENT” to
conrm
Note: The different dimensions to be input depend on the shape of the gemstone. Please refer to Page 16 for shape and their respec­tive dimensions required.
3.2 Previous Settings
Setting of previ­ous gemstone will be displayed:
• Press “ENT” to conrm
[SELECT NAME]
A B C D E F G H I J K L M N O P Q R
[SELECT STONE]
Diamond
Danburite Diopside
[SELECT SHAPE]
Round
Oval Emerald
[PREV. SETTING]
Diamond Round
18
4 Select method
of measure ment: Scroll to select from measure ment or keypad
Press “ENT” to
conrm
4.1 Measurement
Measurement of Diameter:
• Place gem
stone’s diameter on base anvil
• Press “ENT” to conrm
Measurement of Depth:
1. Place gem stone’s depth on base anvil
2. Press “ENT”
to conrm
4.2 Keypad
Keying of Diameter: Key in gem stone’s diameter
To conrm
entry, navigate cursor to and press “ENT”
[SELECT INPUT]
Measurement Keypad
[MEASURE]
0 1 2 3 4 5 6 7 8 9 . Dep.= 3.11 mm
CT/MM
[MEASURE]
0 1 2 3 4 5 6 7 8 9 . Dia .= 4.55 mm
CT/MM
[KEY IN]
0 1 2 3 4 5 6 7 8 9 . Dia .= 4.55 mm
CT/MM
19
Keying of Depth: Key in gem stone’s depth
To conrm
entry, navigate cursor to and press “ENT”
Please note that at any point, pressing Ct/mm will toggle between “Keypad” or “Measurement” input methods
5. Summary of gem­stone’s diameter and depth.
• Press “ENT” to conrm
6. Estimated weight of gemstone will be displayed. At this point, user can either press “Ent” to store or “Cal” for price calculation. Details will be given in 6.1 and
6.2 below
[KEY IN]
0 1 2 3 4 5 6 7 8 9 . Dep.= 3.11 mm
CT/MM
[SUMMARY P1]
Dia . = 4.55 mm Dep. = 3.11 mm
[SUMMARY P2]
Diamond Round weight = 0.299 ct
CAL
20
6.1 Storing Data
Storing of data into inventory:
Press “ENT” to store data
Scroll to select “YES/NO”
If user selects “NO”, display will return to “Select Setting” for next measurement. User will have the liberty to choose between previous or new stones setting.
Press “ENT” to
conrm
[SAVE STONE?]
No
Yes
[SELECT SETTING]
New Setting
Previous Setting
21
6.2 Price Calculation
Price calculation of gemstone:
• Press “CAL”
Keying of price: For data entry, navigate cursor to selected data and press “ENT”
To conrm
price per carat, navigate cursor to and press “ENT”
Price of gemstone will be displayed
6.1 Storing Data
If user selects “YES”, details of gemstone will be stored in “Inventory”
Press “ENT” to
conrm
Upon storing of data, display will return to “Select Setting” for next measurement. User will have the liberty to choose between previous or new stones setting.
[RECORD]
Stone No. 1/16
[ENTER PRICE/CT]
0 1 2 3 4 5
6 7 8 9 . $/ct. =
[ENTER PRICE/CT]
0 1 2 3 4 5
6 7 8 9 . $/ct. = 2000
[PRICE]
Diamond Weight = 0.299 ct $ 598
22
6.2 Price Calculation
Storing of data into inventory:
• Press “ENT”
to store data
• Scroll to
select “YES” in option to store
• Press “ENT” to conrm
• Upon storing of
data, display will return to “Select Setting” for next measurement
Please note only the settings of the stone are stored. Storing function is simi­lar to section 6.1 above. Price of the gemstone will not be stored.
[SAVE STONE?]
No
Yes
23
c. Specic Gravity (S.G.) Dictionary
Presidium Gem Computer Gauge enables the narrowing down of a gemstone by its S.G. Presidium
Gem Computer Gauge (PGCG) includes a dictionary for S.G. values of selected gemstones for your reference.
Please note that the weight of gemstone will be needed
from other source for the identication of gemstone.
Requirement Activation
Key
Display
1. Select S.G.
Dictionary:
Select Mode
Scroll to S.G. Dictionary
Press “ENT” to
conrm
2. Select Gem stone name:
Scroll to select gemstone name by the
rst alphabet
Press “ENT” to
conrm
3. Select Gem stone:
Scroll to select
Press “ENT” to
conrm
[MODE]
Measurement Weight Estimator
S.G. Dictionary
[SELECT NAME]
A B C D E F G H I J K L M N O P Q R
[SELECT STONE]
Diamond
Danburite Diopside
24
4. S.G. value of selected gemstone will be displayed
d. Gemstone Estimator
In order to determine the S.G. of the gemstone to be
tested:
Requirement Activation
Key
Display
1. Select
Gem stone
Estimator:
Select Mode
Scroll to Gem stone Estimator
Press “ENT” to
conrm
[S.G. VALUE]
Diamond S.G. = 3.52
3.51 - 3.53
[MODE]
Weight Estimator S.G. Dictionary
Gemstone Estimator
25
2. Select a Shape3:
Scroll to select
Press “ENT” to
conrm
3
Please refer to Page 16 for the picture il­lustrations of the shapes.
4
The different dimensions to be input depend on the shape of the gemstone. Please refer to Page 16 for different shapes and their respec­tive dimensions required.
3. Select method of measurement:
Scroll to select from measure ment or keypad
Press “ENT” to
conrm
[SELECT SHAPE]
Round
Oval Emerald
[SELECT INPUT]
Measurement Keypad
26
3.1 Measurement
4
Measurement of Diameter
• Place gem
stone’s diameter on base anvil
• Press “ENT” to conrm
Measurement of Depth:
• Place gem
stone’s depth on base anvil
• Press “ENT” to conrm
3.2 Keypad
Keying of Diameter:
Key in gem stone’s diameter
To conrm
entry, navigate cursor to and press “ENT”
[MEASURE]
0 1 2 3 4 5 6 7 8 9 . Dia .= 4.55 mm
CT/MM
[MEASURE]
0 1 2 3 4 5 6 7 8 9 . Dep.= 3.11 mm
CT/MM
[KEY IN]
0 1 2 3 4 5 6 7 8 9 . Dia .= 4.55 mm
CT/MM
27
4 Keying of weight:
Key in gem stone’s weight
To conrm
entry, navigate cursor to and press “ENT”
3.2 Keypad
Keying of Depth:
Key in gem stone’s depth
To conrm
entry, navigate cursor to and press “ENT”
Please note that at any point, pressing Ct/mm will toggle between “Keypad” or “Measurement” input methods
[KEY IN]
0 1 2 3 4 5 6 7 8 9 . Dep.= 3.11 mm
CT/MM
[KEY IN]
0 1 2 3 4 5 6 7 8 9 . Weight.= 0.494 ct
28
5 S.G. value of
gemstone will be calculated. List of gemstones5 with associated SG value will be displayed
5
Please refer to
Page 32-33 for
the list of gem­stones included in PGCG
e. Calculator
Presidium Gem Computer Gauge (PGCG) also allows you to do simple calculations.
Requirement Activation
Key
Display
1. Select
Calculator:
Select Mode
Scroll to Calculator
Press “ENT” to
conrm
Alternatively, press “CAL” to select Calculator
2. Calculation:
• For data entry,
navigate cursor to selected data and press “ENT”
1. Diamondor
2. Glass
3. Lapis lazuli S.G. = 3.51
[MODE]
S.G. Dictionary
Gemstone Estimatort
Calculator
0 1 2 3 4 5
6 7 8 9 . = + -
%
0
0 1 2 3 4 5
6 7 8 9 . = + -
%
0
29
f. Inventory
Presidium Gem Computer Gauge (PGCG) allows you to store details (e.g., identify of gemstone, shape, and weight) of gemstones for reference.
Requirement Activation
Key
Display
1. Select
Inventory:
Select Mode
Scroll to Inventory
Press “ENT”
to conrm
2. All gem stones stored in memory will be listed
3. Select gem stone’s details:
Scroll to select
Press “ENT”
to conrm
[MODE]
Gemstone Estimatort Calculator
Inventory
[SELECT STONE]
1. Ambert
2. Diamond
3. Opal
C
[STONE DETAIL]
2. Diamond Oval Weight = 6.23 ct
C
30
Deletion of all gemstone’s
details:
Scroll to any gemstone record
Press “ENT”
to conrm
4 Deletion of
selected gemstone’s
details:
Scroll to selected gemstone record that you want to delete
Press “ENT”
to conrm
• Press “C” to
delete
Select “Delete” from deletion option and press “ENT”
to conrm
Select “Yes” and press “ENT’ to
conrm
[SELECT STONE]
1. Ambert
2. Diamond
3. Opal
C
[DELETE OPTION]
Delete
Delete all
[DELETE STONE?]
No
Yes
[STONE DETAIL]
1. Ambert
2. Diamond
3. Opal
C
Loading...
+ 227 hidden pages