PRESIDIUM Multi-Tester III, PMuT III User Handbook Manual

1
1
Presidium
Multi-Tester III
(PMuT III)
User Handbook
(English)
2
II. About this book pg. 04
III. About your Presidium Multi-Tester III pg. 05
IV. IMPORTANT NOTICE pg. 07
1. GETTING STARTED with your Presidium Multi-Tester III pg. 08
2. PERFORMING A TEST with your Presidium Multi-Tester III pg. 12
3. READING TEST RESULTS on your Presidium Multi-Tester III pg. 14
4. TAKING CARE of your Presidium Multi-Tester III pg. 15
Contents
(English Version)
3
I. Disclaimers, Exclusions and Limitations of Liability
PLEASE READ AND NOTE PRESIDIUM WARRANTY TERMS AND CONDITIONS as stated in the warranty card. Presidium warranty for its testers are subject to proper use by its users in accordance with all the terms and conditions as stated in the relevant user handbook and shall cover only manufacturing defects.
Due to continuous product improvement, Presidium reserves the right to revise all documents including the right to make changes to the handbook without notice and without obligation to notify any person of such revisions or changes. Users are advised to check Presidium’s website at http://www.presidium.com.sg/ from time to time.
Presidium shall not be responsible for any damage or loss resulting from the use of this tester or handbook, and under no circumstances shall Presidium, its manufacturer or any of its subsidiaries, licensors, distributors, reseller, servant and/or agent be liable for any direct or indirect damages, resulting from the use of this tester.
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, under no circumstances shall Presidium, its manufacturer or any of its subsidiaries, licensors, distributors, reseller, servant and/or agent be responsible for any special, incidental, consequential or indirect damages howsoever caused.
The tester or Presidium Multi-Tester III (PMuTIII) referred to in this handbook is provided and/or sold on an “as is” basis. Except as required by applicable law, no warranties of any kind, either expressed or implied, including, but not limited to, the implied warranties of
merchantability and tness for a particular purpose.
4
II. About this book
Thank you for purchasing the Presidium Multi-Tester III (“PMuTIII” or “tester”).
This handbook is designed to help you set up your tester and describes all you need to know about how to use your tester accurately and take care of it in line with its requirements. Please read these instructions carefully and keep them handy for future reference.
This book also contains the terms and conditions in relation to the use of the tester including the Disclaimer,
EXCLUSION and Limitation of Liability clauses stated above in Section I.
5
III. About your Presidium Multi Tester III
The Presidium Multi Tester III has been developed to help distinguish between colorless diamonds and moissanite using the combined principles of thermal and electrical conductivity.
The measuring probe with electronic circuitry is designed to detect and segregate data collected from the gemstones via a customized micro-controller. The information gathered will be displayed within seconds.
The Presidium Multi Tester III has been subjected to thorough and extensive laboratory tests, and will generally give a clear and reliable reading of the gemstone being tested under proper use. However, you are advised to conduct further supporting tests.
This tester was designed with the following objectives:
• Help in the identication of diamonds and moissanite
with a single instrument;
• Provide fairly consistent and reliable test results under proper use;
• Enhanced ergonomic features, such as visibility of test results, maximum grip comfort, ease of use and portability.
The Presidium Multi Tester III features the following:
• Retractable thermoelectric probe tip that ensures constant pressure between probe tip and gemstone
• Industry’s thinnest probe tip (0.6mm) for testing gemstones as small as 0.02ct
• Metal alert buzzer to ensure that probe tip is in contact with gemstone during testing
• No waiting time between tests
• Ergonomic design with rubberized anti-slip grip for better handling during testing
• 180-degree multi-viewing LED display
• International voltage compatibility
• Low battery indicator
• Automatic power off
6
1 Retractable Probe Tip
2 Power Indicator LED
3 Display Panel
4 Battery Compartment
5 Adaptor Inlet
6 ON/OFF Switch
7 Ergonomic Grip
8 Probe Protective Cap
Included in your package:
• Presidium Multi Tester III
• Metal stone rest
• User handbook
• Warranty card
• Protective carrying case
7
IV. IMPORTANT NOTICE
• Due to the testing methodology, this tester is not intended to test for any colored diamonds, such as blue and black diamonds, as the electrical conductivity of these colored diamonds differs from colorless diamonds.
• Keep the tester dry. Precipitation and all types of liquids or moisture can contain minerals that will corrode electronic circuits. If your tester gets wet, remove the battery, and allow the tester to dry completely before replacing it.
• Do not use, store or expose the tester in dusty and dirty areas. Its moving parts and electronic components can be damaged.
• Do not use, store or expose the tester in hot areas. High temperatures can damage or shorten the life of the tester , damage batteries, and warp or melt certain plastics.
• Do not use, store or expose the tester in cold areas. When the tester returns to its normal temperature, moisture can form inside the tester and damage electronic circuit boards.
• Do not attempt to open the tester other than as instructed in this handbook.
• Do not drop, knock, or shake the tester. Rough
handling might break internal circuit boards and ne
mechanics.
• Do not use harsh chemicals, cleaning solvents, or strong detergents to clean the tester.
• Do not paint the tester. Paint can clog the moving parts and prevent proper operation.
If the tester is not working properly, kindly contact Presidium Customer Service at service@presidium.com. sg or:
Presidium Instruments Pte Ltd No. 6 Penjuru Lane Singapore 609187, Singapore (65) 6379 5000 Attn: Customer Service Executive
8
1. GETTING STARTED with your Presidium Multi Tester III
Powering up your Presidium Multi Tester III
This tester can be powered by either the use of an AC adaptor (optional item sold separately) or through the use of batteries. If AC adaptor is used, connect one end of the AC adaptor to the tester (Fig. 1.1). and the other end directly into an electrical outlet. Please ensure that only the adaptor supplied by Presidium is used.
If batteries are used (3 x AAA batteries), take note of the positive (+) and negative (-) directions of batteries when inserting the batteries into the tester (Fig. 1.2). The use of alkaline batteries is preferred, as it should generally give approximately two and a half hours of continuous operation, while the use of ordinary batteries will give a shorter working life.
Fig. 1.1
Fig. 1.2
9
Turning on your Presidium Multi Tester III
Remove the protective cover from the probe tip (Fig.1.3).
Press the [ON/OFF] button located at the back of the tester (Fig. 1.4). and wait for about 20 seconds to warm up the instrument.
Fig. 1.3
Fig. 1.4
Fig. 1.5
While in this preparation mode, a Green light will blink continuously. The light will stop blinking when it is “READY” to be used (Fig. 1.5).
The tester will shut down automatically after 10 minutes of inactivity.
10
Calibration
All testers have been calibrated during the manufacturing process and no further adjustment or user intervention to the tester is required.
Self-calibration should not be attempted. To minimize any risks associated, users should contact Presidium at service@presidium.com.sg or its service center for assistance. In the event that users require the manufacturer to re-calibrate the unit, the users will bear the associated to/fro freight cost for the shipping of unit to the service center.
Recommended testing conditions
The gemstone should be clean and dry before testing. However, elaborate cleaning procedures are not normally necessary (Fig. 1.6).
Fig. 1.6
The recommended testing temperature is 18°C – 27°C or 65°F- 80°F Please allow the gemstone or jewelry piece to adjust to room temperature prior to testing. Exposure and/or operation of the tester outside the room temperature would affect the results and performance of the tester.
Battery information
Do not leave worn out batteries in the battery compartment as the batteries may corrode, leak or damage the tester. Batteries should be removed when the tester is expected to be stored for an extended period of time.
To prevent inaccurate readings, replace with new battery
11
Fig. 1.7
Fig. 1.8
Gently rub the table of gemstone against the tissue/jewellery cloth and place the gemstone on the centre of the Test Pad (Fig. 1.8).
To prevent inaccurate readings, replace with new batteries as soon as the low battery indicator lights up or starts to blink. A test should not be performed when the battery power is low or weak.
Batteries do not have to be removed when the AC adaptor is in use.
Cleaning your gemstone prior to testing
Prepare a clean tissue. Carefully retrieve the gemstone with tweezers and place the gemstone face down on the table (Fig. 1.7).
12
2. PERFORMING A TEST with your Presidium Multi Tester III
Place the tip of the probe pen against the gemstone and
press the test button. Apply sufcient pressure on the tip
for correct reading.
For mounted jewelry or gemstones:
Hold the jewelry or gemstone with one hand and the tester with the other hand (Fig. 2.1). For proper
operation of the tester, the thumb and index nger must
always be placed on the metal-plated serrated part located on both sides of the tester at all times. Care should be taken when testing mounted jewelry. User must ensure that the stones are securely mounted before conducting a test as gap between stone and setting might lead to inaccurate reading.
Fig. 2.1
Fig. 2.2
For testing loose gemstones:
Place the gemstone on the metal stone rest and hold the metal stone rest with one hand while holding the tester with the other hand (Fig. 2.2).
Tips for using your Presidium Multi-Tester III
The probe tip must be placed at a right angle or perpendicular to the facet of the gemstone for an accurate reading.
13
Fig. 2.3
Tests should be conducted on the table of the gemstone. In the event of any doubt, kindly test on the girdle of the gemstones instead.
For proper operation of the tester, ngers must be placed
on the rubber pads located on both sides of the tester at all times.
To achieve optimum accuracy for tests involving very small mounted gemstones (1.2 mm exposed diameter and below), it is extremely important that no contact is made on any mounted/ metal part of the jewelry piece. The test results will likely result in confusion, as metal is highly conductive and results may indicate that a Moissanite is detected instead.
To achieve optimum accuracy for tests involving very small gemstones (10 points and below), it is important to allow the gemstone to cool down before subsequent tests.
It is advisable to take multiple readings if any doubt exists regarding the test results indicated.
Cleaning the probe tip
Please note that if the tester is being used for the rst
time, or if the tester has not been used for a week, it is advisable to clean the probe tip using a piece of paper to attain a consistent and accurate reading.
• Ensure the unit is switched off.
• Hold the probe pen with the pen tip forming a right-angle (90-degree) with any paper or stone rest (as provided). Gently move in a circular motion without retracting the tip (Fig. 2.3).
• Repeat the same motion several times. The cleaning process is completed and the tester is now ready for use.
14
3. READING TEST RESULTS on your Presidium Multi Tester III
The test results are indicated as follows:
1. Red LED lights up:
• Gemstone with high thermal conductivity such as sapphire or topaz is detected.
• Gemstone with low thermal conductivity such as glass or cubic zirconia will not give any reading on the tester.
2. Yellow LED lights up:
• Moissanite is detected.
3. Green LED lights up:
• Diamond is detected with a continuous audible beep.
• Metal is detected with an intermittent beep at “Metal” segment.
Note: For stones with lower thermal inertia, the Presidium Gem Tester / Color Stone Estimator (PGT/ CSE) or the Presidium Duo Tester (PDT) can be used to further differentiate the type of simulants as they detect a wider simulant range.
15
4. TAKING CARE of your Presidium Multi Tester III
• The probe and wire tip is extremely sensitive and should be handled with care, especially during the removal of the protective cap from the pen tip. Always replace the protective cap of the pen tip when the probe is not in use. Caution should be taken so as not to damage the probe and wire tip.
• Do not leave worn out batteries in the battery compartment as the batteries may corrode, leak or damage the tester. Batteries should be removed when the tester is expected to be stored for an extended period of time.
Your tester is a product of extensive design and craftsmanship and should be treated with care.
Thank you for taking time to go through the user handbook which will enable you to understand your recent purchase better.
Presidium also recommends that you register your warranty by sending the warranty registration card to us or registering online at http://www.presidium.com.sg/
Loading...