Premier Mounts CTM-MS4 User Manual

Page 1
INSTALLATION MANUAL
9531-000-331-06
CTM-MS4
Premier Mounts
3130 E. Miraloma Avenue
Phone: (800) 368-9700 Fax: (800) 832-4888
mounts@mounts.com
www.mounts.com
Page 2
CTM-MS4
Table of Contents
Warning Statements ........................................................................................................................................- 3 -
Parts List ...........................................................................................................................................................- 4 -
Installation Tools ..............................................................................................................................................- 4 -
Mounting Bracket Installation .......................................................................................................................- 8 -
CTM-MS4 Installation ..................................................................................................................................- 11 -
Installing the Flat Panel Display (CTM-MS4) ............................................................................................- 14 -
Technical Specifications ................................................................................................................................- 17 -
Warranty ........................................................................................................................................................- 18 -
Contact Premier Mounts ...............................................................................................................................- 18 -
Notes ................................................................................................................................................................- 18 -
Installation Manual Page - 2 -
Page 3
CTM-MS4
Warning Statements
WARNING: PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE
USE OF ANY PREMIER MOUNTS PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.
WARNING:
WARNING:
WARNING:
THE WALL STRUCTURE MUST BE CAPABLE OF SUPPORTING 300 LBS. IF NOT, THE WALL STRUCTURE MUST BE REINFORCED. PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN, AS OUTLINED IN THE INSTALLATION INSTRUCTIONS, MUST BE ADHERED TO. FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY, OR EVEN DEATH.
SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE INSTALLATION OF THIS PRODUCT. USE PROPER SAFETY GEAR AND TOOLS FOR THE INSTALLATION PROCEDURE TO PREVENT PERSONAL INJURY.
PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS SHOULD BE READ AND COMPLETELY UNDERSTOOD. THE INSTALLATION INSTRUCTIONS MUST BE READ TO PREVENT PERSONAL INJURY AND PROPERTY DAMAGE. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE.
Indicates that the power plug is to be disconnected from the power outlet.
Contact Premier Mounts with any questions - (800) 368-9700
Safety precautions must be taken at all times.
Warning and Caution statements.
Do not install on a structure that is prone to vibration, movement or chance of impact. Failure to do so could result in damage to the flat panel display and/or damage to the mounting surface.
Do not install near heater, fireplace, direct sunlight, air conditioning or any other source of direct heat energy. Failure to do so may result in damage to the flat panel display and could increase the risk of fire.
At least two qualified people should perform the installation procedure. Injury and/or damage can result from dropping or mishandling the flat panel display.
Page - 3 - Installation Manual
Page 4
CTM-MS4
Parts List
NOTE: This wall mount is shipped with all proper installation hardware and components. Make sure that
none of these parts are missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop the installation and contact Premier Mounts (800-368-9700).
Wall Plate (Qty 2)
5/16” Flat Washers (Qty 12)
M6 x 30mm Lateral Shift Locking Screws (Qty 2)
M6 x 12mm Safety Knobs (Qty 2)
Mounting Brackets (Qty 2)
5/16” x 3” Lag Bolts (wooden studs only) (Qty 12)
Griplate™ (Qty 8)
M8 Hex Nut
Qty 2)
(
M8 x 16mm Hex Head
Qty 2)
Bolt (
5/16” x 1-1/4” Mounting Rod Set Screw (Qty 1)
Installation Tools
Phillips Head Screw Driver Soft Material/ Blanket ½ ” Socket and Wrench Pencil Tape Measure Drill Gun Level (Supplied) Thread Depth Indicator (Supplied)
Installation Manual Page - 4 -
Page 5
CTM-MS4
M5 x 25
M5 x 30
M6 x 20
M6 x 25
M6 x 30
(Qty 8) M6 x 35
(Qty 8) M8 x 20
(Qty 8) M8 x 25
(Qty 8) M8 x 30
(Qty 8) M8 x 35
(Qty 8)
(Qty 8)
(Qty 8)
(Qty 8)
(Qty 8)
M8 x 70 (Qty 4)
Nylon spacers and flat washers’ actual size NOTE: The nylon spacers may be stacked to achieve proper spacing.
¼” Nylon
Spacers
½” Nylon
Spacers
5/16” Flat
Washers
1” Nylon Spacers
(Qty 8)
(Qty
12)
(Qty 8) Nylon Sleeves
(Qty 8)
¼” Nylon
Spacers
9/16” Nylon
Spacers
(Qty 8)
(Qty 8)
(Qty 8)
Page - 5 - Installation Manual
Page 6
CTM-MS4
How to Determine the Correct Spacer
1. The following illustration shows a display mounting surface that will not need the use of a spacer.
2. The illustration shows a display mounting surface that will need a spacer to correctly install the mounting plate.
3. Anytime a display has a recessed mounting point,
a spacer must be used.
4. Select the spacer(s) that will create a flush and
level mounting surface for the mounting plate.
5. The following illustration shows how a thread depth indicator should be used to determine which spacer should be used.
6. The following illustration shows how a correctly installed spacer and mounting screw will sit in a recessed mounting point.
Installation Manual Page - 6 -
Page 7
CTM-MS4
r
Thread Depth Indicator
1. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel to
make sure the inserts measure the same full depth and mark it (Figure 1).
2. Locate the correct diameter screw for the thread insert. Compare your marking to the screws (supplied).
3. If your selected screw is longer than the marking on the thread depth indicator, DO NOT USE this screw.
4. The screw length must not bypass the marking. Select another screw size (Figure 2 and 3), until you find
one that comes closest to your mark without going past the mark on the Thread Depth Indicator.
Inverted flat panel display
Marking the depth
Thread insert
Figure 1
Screw
Thread depth indicato
Marking
Screw
Figure 2 Figure 3
Marking
Thread depth indicator
Thread depth
indicator
Installation Manual Page - 7 -
Page 8
p
CTM-MS4
Mounting Bracket Installation
NOTE: Proper installation procedure by qualified personnel as outlined in the installation instructions must be
adhered to. Failure to do so could result in serious personal injury and possible damage to the flat panel.
WARNING: INVERT THE FLAT PANEL PLACE IT ON A SOFT, FLAT SUFRACE TO PREVENT
DAMAGE TO THE FLAT PANEL. USE A BLANKET, FOAM, ETC. FAILURE TO DO SO WILL RESULT IN DAMAGING THE FLAT PANEL. DO NOT LAY THE FLAT PANEL ON THE FLOOR WITHOUT ANY PROTECTION TO THE GLASS. THE FLAT PANEL IS HEAVY AND FRAGILE. AT LEAST TWO QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL.
1. Once the flat panel is inverted, use a measuring tape to find the center of your flat panel measuring from
outside to outside of the flat panel (Figure 4).
2. Using a pencil lightly mark the center of your flat panel (Figure 5).
Measuring tape
Inverted flat panelBottom of flat panel
Top of flat panel
C
L
Mark the center of the flat
anel
Inverted flat panel
C
L
Figure 4 Figure 5
Page - 8 - Installation Manual
Page 9
CTM-MS4
3. Install the nylon spacers (if needed) to the mounting points on the flat panel (Figure 6).
4. Lay the mounting brackets (stamped arrows facing out) - (Figure 7).
Nylon Spacers, If Applicable
Bottom of Flat Panel
Notched Cut Outs
Center Mark
Figure 6
Inverted Flat Panel
Arrows Facing Out
Figure 7
5. Match the center of viewing guide with the centerline you marked in Step 1 (Figure 8).
6. The mounting brackets are designed with a center of viewing guide on the outside (Figure 9).
Installation Manual Page - 9 -
Page 10
CTM-MS4
Mounting Bracket
Notched Cut Out
Figure 8
Bottom of the Flat Panel
Figure 9
7. The Griplate™ has M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires.
EXAMPLE: If your plasma uses M8 x 20 Phillip screws, use the M8 mounting points (Figure 10).
8. Once the mounting brackets are aligned, secure the Gr iplate™ to the flat panel. Use (1) Griplate™ per
mounting point (Figure 11).
NOTE: The dimples of the top Griplate™ have to be facing up and the bottom Griplate™ dimples must
be facing down.
M4 M5 M6 M8
Figure 10
Dimples Facing Up
Dimples Facing Down
Phillips Screw Driver
Dimples Facing Up
Inverted Flat Panel
Dimples Facing Down
Figure 11
Page - 10 - Installation Manual
Page 11
CTM-MS4
(
)
CTM-MS4 Installation
1. Using a (commercially available) wood stud finder, locate the 16" or 24" stud centers behind the wall
(Figure 12).
2. Once found, make a pencil marking on the center of the wood studs (Figure 13).
3. Place the wall plate to the reference line and mark the lag bolt mounting points through the wall plate slots
on the wall (see NOTE below).
Wood Stud Finder
Commercially available
Mark the wall
16"
and the center of the wood studs.
Wood studs behind the wall structure.
16"
Measure and mark the viewing height desired on the wall.
Figure 12 Figure 13
NOTE: Three studs that are 24” apart will need nine (9) lag bolts. Four studs that are 16” apart will need
twelve (12) lag bolts.
Installation Manual Page - 11 -
Page 12
t
CTM-MS4
4. To connect the two wall plates, lie them on a flat surface, end to end. Make sure that the holes line up
(Figure 14).
5. Insert the hex head bolts through the two holes and secure with M8 Hex nuts (Figure 14).
6. Thread the provided set screw into one end of the support rod and mount. Once the lower rod is mounted,
thread in the remaining mounting rod onto the end of the set screw and twist until tight (Figure 14).
M8 x 16mm Hex Head Bolt
Mounting Rod
M8 Hex Head Nu
Set Screw
Figure 14
Page - 12 - Installation Manual
Page 13
CTM-MS4
6. Level the wall plate with the reference arrow pointing up to the ceiling (Figure 15).
7. Drill ¼" pilot holes to the marked wall.
8. Secure the plate using the 5/16" lag bolts and flat washers (Figure 16).
16"
Mark the mounting slot
openings
Wall Plate
Wall Plates
Figure 15
5/16” x 3” Lag Bolts
Figure 16. Wood Installation
Installation Manual Page - 13 -
Page 14
CTM-MS4
Installing the Flat Panel Display (CTM-MS4)
WARNING: AT LEAST TWO QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR
INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL.
1. Raise the flat panel with the mounting brackets secured to the flat panel and insert the top hooks over the
upper rod. The lower hooks should rest on the lower rod (Figure 17).
Wall Plate
Top
Bottom
Figure 17
Page - 14 - Installation Manual
Page 15
CTM-MS4
W
2. Make any lateral shift adjustment and lock it by tightening the screws found on the bottom of the
mounting brackets.
CAUTION
NOTE
: To remove the display from the wall simply loosen the screws using a Phillips screwdriver and
: Do not over tighten the screws to the rods (Figure 18).
lift the unit of the wall carefully.
Lateral Shift
all Plate
Figure 18
Installation Manual Page - 15 -
Page 16
3. Tilt the flat panel and secure the safety knobs to each of the mounting brackets (Figure 19).
NOTE
: To remove the display from the wall simply extend the display to its maximum tilt range, remove the
safety knobs, push the flat panel back to it’s flat position, loosen or remove the lateral shift screws and lift the unit off the wall.
CTM-MS4
Figure 19
Page 16 Installation Manual Page
Page 17
CTM-MS4
Technical Specifications
Figure 20
Installation Manual Page 17
Page 18
CTM-MS4
Warranty
Limited Lifetime Warranty
All Premier Mounts products carry a limited lifetime warranty from ship date against defects in materials and workmanship. Premier Mounts is not liable for improper installation that results in damage to mounts, adapters, display equipment or personal injury.
DISCLAIMER OF WARRANTY THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
.
Contact Premier Mounts
In the event of missing and/or damage equipment, or technical questions, the following information can help in the completion of the installation.
Customer Service – (800) 368-9700 Technical Support – techsupport@mounts.com
Notes
NORTH AMERICA EUROPE
3130 East Miraloma Avenue
Anaheim, CA 92806 USA
USA and Canada –
Phone: 800-368-9700
Fax: 800-832-4888
Other Locations – Phone: (001)-714-632-7100; Fax: (001)-714-632-1044
Shilton, Coventry, England CV79JY
Swallow House,
Shilton Industrial Estate,
Phone: +44 (0) 2476 614700
Fax: +44 (0) 2476 614710
AUSTRALIA, NEWZEALAND,
OCEANIA (DISTRIBUTOR)
P.O. Box 295
Mordialloc Victoria 3195
Australia
Phone: 03 9586 63 30
www.premiermounts.com.au
©Premier Mounts 2007
Page 18 Installation Manual
9531-000-331-06
Loading...