Service & Warranty
Do not operate any product with a damaged cord or plug, or after the product malfunctions, or is dropped or appears damaged in any way. Return the complete product to the place of purchase for inspection, repair or replacement.
For your convenience, record the complete Model/Type Number (located on the Product Identification Plate) and the date you received the product below, and attach your purchase receipt docket as proof of purchase.
To ensure your product is covered by warranty, the complete faulty product together with your purchase receipt should be returned to your retailer.
ONE (1) YEAR LIMITED WARRANTY
SAVE THIS WARRANTY INFORMATION
EHS (International) Ltd. guarantees this product free from
defects in materials and workmanship for a period of one (1) year.
Should this unit be operated under conditions other than those recommended or at voltages other than the voltage indicated on the unit, or any attempts made to service or modify the unit, this will render WARRANTY VOID. The product you buy may sometimes differ slightly from illustration.
Should you have a problem with this product, please contact to our Service Desk, Tel: 0870 742 5021.
EHS, Manchester UK, M17.1RN
MODEL WG-UH60
ON
OFF
ON
OFF
THANK YOU FOR CHOOSING THIS EHS
PRODUCT. BEFORE USING IT, PLEASE
READ THIS INSTRUCTION MANUAL
Page 2
1. Important Safety Instructions
When using any electrically powered product, basic safety precautions should always be followed, including the following:
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE
USING THE PRODUCT.
WARNING - to reduce the risk of fire, electrical shock or injury to
persons or property:
1. Great care must be taken when humidifiers are used in children's rooms. Do
not allow the power cord to hang down where children can reach it. Keep the unit well back from the edge of tables so that it cannot be upset. Children should not be allowed to play with the packing materials used with this product.
2. Do not use this appliance near baths, washbasins or shower units.
3. If this appliance becomes immersed in water, unplug it before removal and do
not reuse until it has been checked by an authorized service department.
4. The appliance must not be operated (disconnect the mains plug immediately)
when:
the appliance, casing or cable is damaged.
the appliance shows visible signs of damage.
a fault is suspected after a fall or the like.
5. Disconnect the mains plug:
in case of faults during use.
before cleaning or moving the appliance from place the place.
after use.
6. Never pull the plug out of the socket with wet hands.
7. Never carry nor pull the appliance by the flex.
8. Do not bend the flex or wind it around the appliance.
9. Do not use in freezing conditions.
10. Do not run the cable under a carpet or rug. Arrange the cable so that it is
located out of those areas used most frequently, and in such a way that no one can trip over it.
11. Never put the appliance on hot surfaces or near open flames. Lay the flex so
that it does not touch hot or sharp-edged objects.
12. Attention! The appliance is hot after it is switched off. Let it stand for a short
time before it is moved. Do not operate the appliance in the open air.
13. Never fill hot water in the water tank.
14. Never add fragrant oils.
15. Position the appliance so that steam emitted does not damage wooden
furniture or other items.
16. Never operate the appliance with any air opening blocked. Keep ventilation
openings free from dust. Never drop or insert any object into any opening.
17. Only trained personnel should repair electrical appliances. Unskilled repairs
can cause considerable danger to the user.
18. If the connection cord is damaged, it must be replaced by the manufacturer, his after-sales services department or qualified person in order to avoid risks.
2. BS Plug Wiring
Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code :
BLUE - NEUTRAL
BROWN - LIVE
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
1. The BLUE wire is the NEUTRAL and must be connected to the
terminal marked with the letter N or coloured BLACK.
2. The BROWN wire is the LIVE and must be connected to the
terminal marked with the letter L or coloured RED.
3. Always ensure that the cord grip is positioned and fastened
correctly.
If a 13A (BS 1363) fused plug is used it must be fitted with a 3A fuse. If in doubt consult a qualified electrician.
Wiring for a 13 Amp Plug (BS1363)
READ & SAVE THESE
IMPORTANT INSTRUCTIONS
Page 3
3. Product Description
Features
Large 6.8ltr capacity water tank
Transparent water tank
Easily Transportable due to unitary construction
Warm humidity function (After approximately 60 minutes a mist
temperature of 30 degrees C is obtained.)
Ultrasonic cool mist
Fresh ionic generator
Water filter (Ion Exchange Resin)
Adjustable nozzle
Mist output: 350-550ml/hr
ON
OFF
ON
OFF
Handle
Tank
Water Filter (inside tank)
Control Panel
Base
Ionizer Outlet
Nozzle
Pre-Operation Instructions
1. Carefully remove your humidifier from the box (please save the carton for off-season storage).
2. Remove tank and check for damage.
3. Place on firm watertight level surface.
4. Caution
1. Please read the instructions carefully before using the humidifier.
2. Please make sure that the humidifier is placed on a solid, waterproof surface. Do not allow the unit to come into contact with soft furnishings or polished wood surfaces.
3. Turn off and plug must be pulled out of the socket while adding water or moving the humidifier.
4. Do not immerse the unit in water.
5. Cut off the power when the water tank is empty.
6. Do not use hot water.
7. Clean and de-scale the unit regularly.
5. Operation
FILLING WATER
Disinfect the humidifier when you use the humidifier for the first time (please refer to the cleaning instructions)
1. Turn off and unplug the humidifier.
2. Remove nozzle.
3. Lift water tank from base.
4. Turn over the water tank than open filling hole cap of water tank by unscrewing anti-clockwise and fill tank with clean cold water only.
5. Close filling hole cap by screwing clockwise.
6. Turn over the water tank to upward. Make sure that it does not leak. Put water tank back on base.
7. Put nozzle back to water tank and adjust the desired direction.
Attention:
1. Use the under -side care handle when carrying the fully filled water tank and place another hand under for assistance.
2. Do not put water into the base directly otherwise it will be damaged or cause danger.
3. Do not move the appliance when the water tank is fully filled with water.
4. Place on firm watertight level surface.
Page 4
PANEL
Heat
ON
OFF
ON
OFF
Empty tank warning light Heater (warm mist) on light Main power on light
Main power and mist volume control
Heater on/off control
TO OPERATE
CAUTION: Do not touch the socket when your hands are wet.
1. Turn both switches to OFF position.
2. Plug appliance into wall outlet (220-240V~).
3. Turn the main (mist) control to ON position until you hear a “click” sound and main power light goes ON.
4. The ionizer and ultrasonic misting is now running once power is ON.
Ionizer
The ionizer has the capacity of more than 2.5 million negative ions per cm3. The ions will be dispersed in the air and trap the impurities such as smoke, pollen and other suspended particles. This will then be neutralized. This will be a great aid to controlling allergens and ridding the air of floating particles.
5. Turn switch to desired misting volume output.
WARM MIST
6. Turn heater control switch to ON position. The heater on light goes ON.
ATTENTION: Anytime after use, switch off and unplug the unit. WATER FILTER
The unit comes with an integral water filter. This removes minerals such as calcium and chlorine which are present in tap water to a greater or lesser degree. After a period of time depending on conditions of use the filter will need cleaning. This is done by adding salt {Sodium Chloride - NaCl} to the water to release the collected minerals. This process rejuvenates the filter.
REFILL
The humidifier will automatically cut off when water is running out. Empty tank warning light goes ON.
Turn off and unplug the unit before refilling. The tank will need to be refilled.
6. Maintenance
CLEANING
Always switch the appliance off and then remove the plug from the mains socket before cleaning. Clean only with a dry or damp cloth, if necessary moistened with a little washing liquid. Do not use any abrasives or detergents.
When necessary disinfect the tank using a mild bleach solution or 'baby bottle' cleaner.
DE-SCALING
De-scale the unit frequently using either a standard kettle de-scaler or diluted vinegar solution. Do not operate the unit whilst de-scaling is in process.
DO NOT IMMERSE PRODUCT IN WATER Caution: Do not allow water to run into the interior of the
humidifier as this could create a fire or electric shock hazard. CLEANING THE FILTER
When using the filter for the first time please add salt (Sodium Chloride NaCl) to a container of water and immerse the filter for about 1 hour. Simple immersion in the salt solution is sufficient. This should be in a 6% solution or approximately one table spoon of table salt in one liter of water. The filter should be rinsed in purified water after this procedure and replaced in the tank. This procedure is recommended after long use of the filter. This will rejuvenate the filter for long use. After the season is over or if the unit is to be stored, please repeat this process before storage so as to get the best results from your filter and unit. This will keep the Ion Exchange Resin material in optimum condition.
Page 5
STORAGE
1 Store the appliance after cleaning and drain away any residual water.
Make sure it is dry.
2 After the season is over or if the unit is to be stored, please add salt
(Sodium Chloride NaCl) to a container of water and place the filter for about 1 hour. Please clean in this procedure before storage so as to get the best results from your filter and unit.
3 Wrap the appliance into the original gift box and keep in a cool dry
place.
7. Specification
Model : WG-UH60 Voltage : 220-240V~ 50Hz Power : 40W (Ultrasonic) / 130W (Heater) Water tank : 6.8L Capacity Ionizer : >2.5 million / cm3
NOTE: If you experience a problem, please return the product to your supplier with your warranty or proof of purchase. Do not attempt to open the product. Doing so may void your warranty and cause damage to the product or personal injury. If the supply cord is damaged it must be replaced by a qualified electrician.
Loading...