SPECIFICATION
Model no. PKY12 Cooling capacity 12,000 BTU/hr Power/Ampere consumption for cooling* 1250W / 5.7 A Air volume (max. speed) 350m
3
/h
Humidity removal capacity 36 L/day Power supply 220~240V/50Hz/1phase Compressor Rotary Refrigerant R407C Refrigerant load* 500g Fan speed 3 + Auto Timer 24 hours Working temperature Cooling: 16 ~32
o
C
Exhaust pipe 130 x1800mm Net Weight 31kgs Gross Weight 35kgs Product Dimension (WxDxH) 370 x 400 x 760 mm
Please note: The data marked with '*' may vary for technical reasons: for greater
precision, please refer to the rating label placed at the back of the unit. Measuring condition for above is: Cooling – DB 27oC , WB 19oC
INTRODUCTION
This Portable Air Conditioner is designed for improving living and working comfort by adjusting the temperature and humidity in a room. Its mobility makes it easy to use in various rooms.
To ensure the optimal efficiency of the air conditioner, we advise you to keep doors and windows closed, and to take into account the surface of the walls and windows exposed to the sun. In this case, in order to optimize the functioning of your air conditioner, we recommend partially closing window coverings.
RECOMMENDED USE
This unit is designed to be used in the room only, not for outdoor. Do not locate the unit where furniture or other objects can obstruct the cooling airflow. Always keep the filter clean. Prevent any kink or blend in the middle of exhaust hose.
The following advice and instructions should be followed closely:
1. Your unit must always be used in an upright position because it contains a cooling agent.
2. After unpacking, place the unit upright to allow the cooling agent to stabilise, and wait 3 hours before use.
IMPORTANT SAFETY INSTRUCTIONS
1. Transport & store the unit in an upright position only. Leave it in an upright position for at
least 3 hours before first use.
2. Always place the unit on an even, level surface.
3. An opening in a window or wall is required to accommodate the exhaust hose to expel the
hot air.
4. Ensure the unit is connected to an earthed power supply of the correct rating. (Refer to the
rating label located at the back of the unit).
5. The unit will cool when the room temperature is between 16°C~32°C depending on the
thermostat setting.
6. DO NOT use this unit for functions other than those described in this instruction manual.
7. DO NOT tilt the unit.
8. DO NOT cover or obstruct the appliance’s inlet and outlet grilles.
6. Your air conditioner has been designed to be used only in the home, office and similar
conditions and should not be used for any other purpose.
7. This unit is for indoor use only.
8. Never unplug the air conditioner while it is working, this could damage the electronic
circuits.
9. DO NOT use the appliance in a wet room, such as a bathroom or laundry room to avoid
the risk of electrical shocks.
10. DO NOT bend or crush the warm air exhaust hose.
11. DO NOT sit or place articles on the appliance.
12. DO NOT use the appliance with wet or damp hands.
13. DO NOT let chemical substances come into contact with the appliance.
14. DO NOT use the appliance in the presence of flammable substances or such as alcohol,
insecticides, petrol, etc.
15. DO NOT use the plug to start and stop the appliance. ALWAYS use the intended control
panel to start and stop the unit.
16. ALWAYS turn off the appliance when it is not in use and remove the mains plug from the
socket outlet.
17. ALWAYS turn the unit off and remove the mains plug before cleaning, carrying out
maintenance or moving location.
18. Avoid the use of adapter plugs, multiple sockets and /or extension leads. If their use is
necessary, ensure they conform to current safety standards.
19. Do not pull the electrical cable or place it near a source of heat: always unroll it completely
to avoid dangerous overheating. If the power cord becomes damaged, the service agent or a similarly qualified person must replace it, in order to avoid a hazard.
20. The filter must be used with the product at all times, when removing it for clearing always
turn the unit off and unplug the mains plug from the socket.
21. Do not operate the unit with a damaged power cord or
plug, after it malfunctions, has been dropped or damaged. If the power cord is damaged it must be replaced by the manufacturer or a qualified service engineer to avoid a hazard.
22. Closely supervise any children and pets when unit is in use
23. Only use in the upright position on a flat level surface, at
least 50cm from any objects.
BS PLUG WIRING INSTRUCTIONS
Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code:
BLUE - NEUTRAL
BROWN - LIVE
GREEN AND YELLOW - EARTH
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
1. The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked
with the letter N or coloured BLACK.
2. The BROWN wire is the LIVE and must be connected to the terminal which is marked with
the letter L or coloured RED.
3. The GREEN/YELLOW is the EARTH and must be connected to the terminal which is
marked with the letter E or or coloured GREEN OR GREEN/YELLOW.
4. Always ensure that the cord grip is positioned and fastened correctly.
If a 13A (BS 1363) fused plug is used it must be fitted with a 13A (BS 1362) fuse. If in doubt
consult a qualified electrician.
Wiring for a 13 Amp Plug (BS 1363) Please note. The Earth Terminal is marked with the letter E or Earth Symbol
Loading...
+ 8 hidden pages