Prem-I-Air ACS16E Instruction Manual

MMOOBBIILLEE AAIIRR CCOONNDDIITTIIOONNEERR
IINNSSTTRRUUCCTTIIOONN MMAANNUUAALL
MMOODDEELL AACCSS1166EE
IMPORTANT
Please read these instructions carefully before use.
Page 2
CCoonntteennttss
Important safety instructions
BS Plug Wiring Instruction
Technical Specification
Energy Saving Advice
Component Layout
Control Panel Operation
Use Of Control Panel
Control of Airflow Direction
Disconnecting The Refrigerant Line
Mounting The Outdoor Unit
Installing The Carbon Filters
Maintenance
End Of Season Storage
Troubleshooting
Service & Warranty
Page 3
IIm
mppoorrttaanntt SSaaffeettyy IInnssttrruuccttiioonnss
1. Transport & store the unit in an upright position only. Leave it in an upright position for at least 3 hours before first use.
2. Always place the unit on an even, level surface.
3. An opening in a window or wall is required to accommodate the exhaust hose to expel the hot air.
4. Make sure the unit is connected to an earthed power supply of the correct rating. (Refer to the rating label located at the back of the unit).
5. The unit will cool when the room temperature is between 18°C~32°C depending on the thermostat setting.
6. Operate this unit in an ambient temperature of 32°C or lower.
7. Do not operate the unit with a damaged power cord or plug, after it malfunctions, has been dropped or damaged. If the power cord is damaged it must be replaced by the manufacturer or a qualified service engineer to avoid a hazard.
8. DO NOT use this unit for functions other than those described in this instruction manual.
9. DO NOT tilt the unit.
10. DO NOT cover or obstruct the appliance’ s inlet and outlet grilles.
11. Your air conditioner has been designed to be used only in the home, office and similar conditions and should not be used for any other purpose.
12. Never unplug the air conditioner while it is working, this could damage the electronic circuits.
13. DO NOT use the appliance in a wet room, such as a bathroom or laundry room to avoid the risk of shock.
14. DO NOT sit or place articles on the appliance.
15. DO NOT use the appliance with wet or damp hands.
16. DO NOT let chemical substances come into contact with the appliance.
17. DO NOT use the appliance in the presence of inflammable substances or vapours such as alcoh ol, insecticides, petrol, etc.
18. DO NOT use the plug to start and stop the appliance.
19. ALWAYS use the control panel to start and stop the unit.
20. ALWAYS keep an air path of at least 50cm from walls, furniture or curtains.
21. ALWAYS turn off the appliance when it is not in use and remove the mains plug from the socket outlet.
Page 4
22. ALWAYS turn the unit off and remove the mains plug before cleaning, carrying out maintenance or moving location.
23. Avoid the use of adapter plugs, multiple sockets and /or extension leads. If their use is necessary, ensure they conform to current safety standards.
24. Do not pull the electrical cable or place it near a source of heat: always unroll it completely to avoid dangerous overheating. If the supply cord becomes damaged, the service agent or a similarly qualified person must replace it, in order to avoid a hazard.
25. The filter must be used with the product at all times, when removing it for clearing always turn the unit off and unplug the mains plug from the socket.
For those who are not aware of the danger that might occur from
the usage of an electrical appliance, they should use the product under guidance and supervision.
TTHHEE MMAANNUUFFAACCTTUURREERR DDIISSCCLLAAIIMMSS AANNYY
RREESSPPOONNSSIIBBIILLIITTYY IIFF TTH
HEE AABBOOVVEE IINNSSTTRRUUCCTTIIOONNSS
AARREE NNOOTT FFOOLLLLOOWWEEDD..
Page 5
BBSS PPlluugg W
Wiirriinngg
Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code:
BLUE - NEUTRAL
BROWN - LIVE
GREEN AND YELLOW - EARTH
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
1. The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked with the letter N or coloured BLACK.
2. The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED.
3. The GREEN/YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN OR GREEN/YELLOW.
4. Always ensure that the cord grip is positioned and fastened correctly.
If a 13A (BS 1363) fused plug is used it must be fitted with a 13A fuse. If in doubt consult a qualified electrician.
Wiring for a 13 Amp Plug (BS1363)
Please note. The Earth Terminal is marked with the letter E or Earth Symbol
Page 6
TTeecchhnniiccaall SSppeecciiffiiccaattiioonn
Model no.
ACS16E
Power supply
220-240V/ 50Hz / 1 phase
Cooling capacity
16000BTU/hr, 4039Kcal/hr,
4689watts
Heating capacity
16000BTU/hr, 4039Kcal/hr, 4689watts
Power / Ampere consumption for cooling
1750W/ 7.5A
Power / Ampere consumption for heating
1280W/ 5.8A
Max. airflow volume (indoor unit)
750 m3/h
Humidity removal capacity
53L/day
Compressor
Rotary
Refrigerant
R-407C
Refrigerant load*
1.25Kg
Fan speed
3
Timer
1 ~ 12 hours
Working temperature
Indoor unit: 18 ~ 32oC
Outdoor unit: 21 ~ 43
o
C
Indoor unit
35 kg
Net weight
Outdoor unit
13 kg
Indoor unit
360 x 590 x 757 mm
Size
Outdoor unit
500 x 310 x 525 mm
Length of connection tube
3 m
Recommended room size
28m
2
* For models with heat function only.
Measuring condition for above is:
Cooling – Indoor: RT27
o
C, RH60%
Outdoor: RT35
o
C, RH50%
Heating - Indoor: RT20
o
C, RH60%
Outdoor: RT7
o
C, RH85%
Loading...