No. 9113V107-BR Versão do produto: 9113-004
Communication
Display
I.S. Interface
Isolation
Multifunction
Temperature
6 Product Pillars
to meet your every need
With our innovative, patented technologies, we make signal conditioning smarter and simpler. Our portfolio is composed of six product areas, where we offer a wide range of analog and digital devices covering over a thousand applications in industrial and factory automation. All our products comply with or surpass the highest industry standards, ensuring reliability in even the harshest of environments and have a 5-year warranty for greater peace of mind.
Individually outstanding, unrivalled in combination
Our range of temperature transmitters and sensors provides the highest level of signal integrity from the measurement point to your control system. You can convert industrial process temperature signals to analog, bus or digital communications using a highly reliable point-to-point solution with a fast response time, automatic self­calibration, sensor error detection, low drift, and top EMC performance in any environment.
Our unique range of single devices covering multiple applications is easily deployable as your site standard. Having one variant that applies to a broad range of applications can reduce your installation time and training, and greatly simplify spare parts management at your facilities. Our devices are designed for long-term signal accuracy, low power consumption, immunity to electrical noise and simple programming.
We provide inexpensive, easy-to-use, future-ready communication interfaces that can access your PR installed base of products. The detachable 4501 Local Operator Interface (LOI) allows for local monitoring of process values, device configuration, error detection and signal simulation. The next generation, our 4511 Remote Operator Interface (ROI) does all that and more, adding remote digital communications via Modbus/RTU, while the analog output signals are still available for redundancy. With the 4511 you can further expand connectivity with a PR gateway, which connects via industrial Ethernet, wirelessly through a Wi-Fi router or directly with the devices using our Portable Plant Supervisor (PPS) application. The PPS app is available for iOS, Android and Windows.
Our display range is characterized by its flexibility and stability. The devices meet nearly every demand for display readout of process signals, and have universal input and power supply capabilities. They provide a real-time measurement of your process value no matter the industry, and are engineered to provide a user-friendly and reliable relay of information, even in demanding environments.
We deliver the safest signals by validating our products against the toughest safety standards. Through our commitment to innovation, we have made pioneering achievements in developing I.S. interfaces with SIL 2 Full Assessment that are both efficient and cost-effective. Our comprehensive range of analog and digital intrinsically safe isolation barriers offers multifunctional inputs and outputs, making PR an easy-to-implement site standard. Our backplanes further simplify large installations and provide seamless integration to standard DCS systems.
Our compact, fast, high-quality 6 mm isolators are based on microprocessor technology to provide exceptional performance and EMC-immunity for dedicated applications at a very low total cost of ownership. They can be stacked both vertically and horizontally with no air gap separation between units required.
9113 - Versão do produto 9113-004 3
Conversor mA / temperatura
9113
Conteúdo
Aviso................................................................................................... 4
Identificação de símbolos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Instruções de segurança ................................................................................. 4
Como desmontar o sistema 9000......................................................................... 5
Recursos avançados ..................................................................................... 6
Aplicação . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Características técnicas.................................................................................. 6
Aplicações .............................................................................................. 7
Display PR 4511/4501 / programador frontal ............................................................. 8
Como montar / desmontar o PR 4511/4501............................................................... 8
Código de compra ....................................................................................... 9
Acessórios .............................................................................................. 9
Especificações elétricas.................................................................................. 9
Configuração de verificação de erro do sensor ............................................................. 13
Sinal de entrada fora do range......................................................................... 13
Detecção de erro do sensor ........................................................................... 13
Indicações de erro.................................................................................... 14
Conexões ............................................................................................... 15
Diagrama de bloco....................................................................................... 16
Indicações de falha de cabo e erro de sinal sem display frontal.............................................. 17
Configuração / operando os botões de função ............................................................. 18
Diagrama de encaminhamento ........................................................................... 20
Diagrama de encaminhamento, configurações avançadas (ADV.SET)......................................... 22
Textos de ajuda na linha 3 do display ..................................................................... 23
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
IECEx Installation Drawing ............................................................................ 25
ATEX Installation Drawing ............................................................................ 29
FM Installation Drawing............................................................................... 33
Desenho de instalaçao INMETRO ...................................................................... 36
História do documento................................................................................... 39
Safety Manual........................................................................................... 40
4 9113 - Versão do produto 9113-004
Aviso
As operações seguintes devem apenas ser realizadas com o módulo desconectado e sob as condições ESD-segurança: Montagem geral, conexão e desconexão de fios. Solução de problemas do módulo.
Reparo do módulo e substituição de circuitos danificados devem ser feitos apenas pela PR electronics A/S.
Aviso
Não abra a placa frontal do equipamento de forma que possa causar dano no conector do display / programador frontal PR 4511/4501. Este equipamento não contém DIP-switches ou jumpers.
Identificação de símbolos
Triângulo com marca de exclamação: Leia o manual antes da instalação e comissionamento do módulo a
fim de evitar incidentes que podem causar danos pessoais ou mecânicos.
O certificado CE prova a observância do módulo com os requerimentos essenciais das diretrizes.
O símbolo de isolação dupla mostra que o módulo é protegido por isolação dupla ou reforçada.
Equipamentos Ex tem sido aprovados de acordo com a diretriz da ATEX para uso em instalação de áreas explosivas. Veja os desenhos de instalação no apêndice.
Instruções de segurança
Definições
Tensões perigosas foram definidas com os ranges: 75...1500 Volt DC, e 50...1000 Volt AC. Técnicos são pessoas qualificadas, educadas ou treinadas para montagem, operação, e também solucionar problemas técnicos
de acordo com as normas de segurança. Operadores, estarem familiarizados com os conteúdos deste manual, ajustarem e operarem os botões ou potenciômetro durante uma operação normal.
Recebimento e desembalagem
Desembalar o equipamento sem danifica-lo e checar se o tipo do equipamento corresponde com o solicitado. A embalagem deve sempre acompanhar o produto até que o mesmo seja permanentemente montado.
Ambiente
Evite contato direto com luz do sol, poeira, altas temperaturas, vibrações mecânicas e choques, bem como chuva e umidade pesada. Se necessário, aquecimento em excesso dos limites permitidos para temperaturas ambiente devem ser evitadas por meio de ventilação. O módulo deve ser instalado em grau de poluição 2 ou melhor. O módulo foi projetado para estar seguro de altitudes de até 2000 metros.
9113 - Versão do produto 9113-004 5
Montagem
Apenas técnicos os quais estão familiarizados com termos técnicos, avisos e instruções contidas no manual e o quais são capazes de segui-lo, devem conectar o módulo. Caso haja alguma dúvida, favor entrar em contato com seu distribuidor local ou, alternativamente,
PR electronics A/S
www.prelectronics.com
O uso de cabos trançados, não é permitido para a fiação da rede, exceto quando os fios estão protegidos com as extremidades do cabo.
Descrições de conexão de entrada / saída e alimentação são mostradas no diagrama de blocos na etiqueta lateral.
O módulo é fornecido com terminais de fiação de campo e devem ser alimentados por uma fonte de alimentação com isolação dupla ou reforçada. um interruptor deve ser facilmente acessado e estar perto do módulo. Este interruptor deve ser marcado como modo de desconexão para o módulo.
Para instalação no trilho de alimentação 9400 a tensão é fornecida pela Unidade de Controle de Tensão 9410.
O ano de fabricação pode ser pego nos dois primeiros dígitos do serial number.
Calibração e ajuste
Durante a calibração e ajustes, a medição e conexão de tensões externas devem ser realizadas de acordo com as especificações do manual. O técnico deve usar ferramentas e instrumentos que são seguros para uso.
Operação normal
Operadores são apenas permitidos a ajustar e operar equipamentos que estão fixados de forma segura no painel, etc., evitando-se assim o risco de ferimentos e danos. Isso significa que não há risco de choque elétrico, e o equipamento é facilmente acessível.
Limpeza
Quando desconectado, o equipamento pode ser limpado com pano umedecido e água destilada.
Responsabilidade
Na medida em que as instruções deste manual não sejam estritamente observadas, o cliente não pode avançar uma demanda contra a PR electronics A/S após o contrato de venda ter sido aceita.
Como desmontar o sistema 9000
Figura 1:
Levantando o botão de trava, oequipamento é destacado do trilho DIN.
6 9113 - Versão do produto 9113-004
Recursos avançados
• Configuração e monitoramento através do display frontal destacável (PR 4511/4501).
• Copiar a configuração de um equipamento para outro do mesmo tipo via PR 4511/4501.
• Entradas TC podem usar ou o CJC interno ou um terminal com Pt100 imbutido para grande precisão.
• Monitoramento avançado da comunicação interna e armazenamento de dados.
• A funcionalidade SIL 2 é opcional e deve ser ativada no ponto do menu.
Aplicação
• O equipamento pode ser montado em área segura ou em zona 2 / div. 2 e transmitir sinais para zona 0, 1, 2 e zona 20, 21, 22 incluindo mineração M1 / Classe I/II/III, Div. 1, Gr. A-G.
• Conversão e scala de temperatura (Pt, Ni e TC) e sinal de corrente ativo.
• O 9113 foi projetado, desenvoldido e certificado para uso em aplicações SIL 2 de acordo com os requerimentos da IEC
61508.
Características técnicas
• 1 LED verde e 2 vermelhos indicam status de operação e funcionamento.
• Isolação galvânica de 2,6 kVAC entre entrada, saída e alimentação.
Conversor mA / temperatura
9113
• Entrada para RTD, TC e mA
• Saída mA ativa / passiva via os mesmo dois terminais
• 1 ou 2 canais
• Pode ser alimentado separadamente ou instalação no trilho de tensão, PR type 9400
• Certificado SIL 2 via Levantamento Completo
54
53
52
51
44
43
42
41
44
43
42
41
14
13
12
11
mA
+
-
mA
+
-
mA
+
mA
+
31
32
33
34
9113 - Versão do produto 9113-004 7
Trilho, alimentação +
Trilho, alimentação -
Trilho de tensão
Sinal de relé de status
Status do equipamento
Status do equipamento
Alimentação +19,2...31,2 VDC
N.C.
Alimentação via trilho de tensão
Sem conexão
Sem conexão
Conexão de tensão:
Aplicações
Alimentação -
*
-
+
Zona 0, 1, 2,
20, 21, 22, M1 &
Cl. I/II/III, Div. 1
gr. A-G
Zona 2 / Cl. 1, div. 2, gr. A-D ou área segura
Canal 2:
Sinais de saída:
Analógico, 0/4...20 mA
Sinais de entrada:
Canal 1:
Alimentação 2 fios -
Canal 2:
Canal 1:
Alimentação 2 fios -
*
Conexão
RTD,
fios
TC
Corrente
*Vendido separadamente: Conector CJC 5910Ex / 5913Ex
Conexão
RTD,
fios
TC
Corrente
*Vendido separadamente: Conector CJC 5910Ex / 5913Ex
OK
4501


1
3

4
2
3
4
8 9113 - Versão do produto 9113-004
Display PR 4511/4501 / programador frontal
Funcionalidade
A estrutura simples do menu e de fácil compreensão e os textos explicativos de ajuda te orientam sem dificuldades e automaticamente através dos passos, tornando assim o produto fácil de usar. Opções de funções e configurações são descritos na seção “Configuração / botões de operação e função”.
Aplicação
• Interface de comunicação para modificações dos parâmetros operacionais no 9113.
• Pode ser movido de um 9113 para outro e baixar a configuração da primeira unidade para subsequentes unidades.
• Quando montado no processo, o display mostra os valores do processo e status do equipamento.
Características técnicas
• Diplay de LCD com 4 linhas: Linha 1 (5,57 mm) mostra o status de entrada. Linha 2 e 3 (H=3,33 mm) mostram o valor de entrada / saída analógico ou o número de tag e unidades. Linha 4 mostra o status para comunicação e se o equipamento está bloqueado por SIL. Dot estática = bloqueado por SIL e dot piscando = sem bloqueio por SIL.
• O acesso à programação pode ser bloqueado atribuindo uma senha. A senha é salva no equipamento a fim de garantir um alto nível de proteção contra modificações não autorizadas na configuração.
Como montar / desmontar o PR 4511/4501
1: Insira os grampos do 4511/4501 nos encaixes localizados no topo do equipamento. 2: Pressione o 4511/4501 no lugar.
Desmontagem do 4511/4501
3/4: Aperte o botão na parte inferior do 4511/4501 e puxe para cima.
9113 - Versão do produto 9113-004 9
Acessórios
4501 = Display / programador frontal 4511 = Communication enabler 5910Ex = Conector CJC, canal 1 5913Ex = Conector CJC, canal 2 9400 = Trilho de tensão 9404 = Módulo de parada para trilho 9410 = Unidade de controle de alimentação 9421 = Fonte de alimentação 24 V - Ex nA nC
Especificações elétricas
Condições ambientais:
Especificações de range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -20°C a +60°C
Temperatura de armazenamento . . . . . . . . . . . . . . . . . . . . . . . . . . -20°C a +85°C
Temperatura de calibração . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20...28°C
Umidade de relativa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 95% RH (non-cond.)
Grau de proteção . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP20
Instalação em grau de poluição 2 e categoria de sobretensão II.
Especificações mecânicas:
Dimensões (HxWxD). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 x 23,5 x 104 mm
Dimensões (HxWxD) com 4501 / 4511 . . . . . . . . . . . . . . . . . . . . . . 109 x 23,5 x 116 mm / 131 mm
Peso (approx.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 g
Peso com 4501 / 4511 (approx.) . . . . . . . . . . . . . . . . . . . . . . . . . . 265 g / 350 g
Tipo de trilho DIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DIN EN 60715 - 35 mm
Tamanho de cabo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,13...2,08 mm
2
/ AWG 26...14 cabo flexível
Torque de terminal de parafuso . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,5 Nm
Vibração . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IEC 60068-2-6
2...13.2 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±1 mm
13.2...100 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0,7 g
Especificações comuns:
Tensão de alimentação . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19,2...31,2 VDC
Fusível . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 mA SB / 250 VAC
Código de compra
Exem plo : 9113BB
Tipo Canais
9113B Simples
Duplo
: A
: B
10 9113 - Versão do produto 9113-004
A potência necessária máxima é a potência máxima necessária nos terminais 31 e 32. A dissipação de potência máxima é a potência máxima dissipada pelo dispositivo 9000. Se o 9113 for utilizado com o 4511/4501, adicione 40 mW ao dissipação de potência máxima e 70 mW ao potência necessária máxima para cada dispositivo com o 4511/4501.
Tensão de isolação, teste / operação:
De qualquer entrada. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,6 kVAC / 300 VAC reforçada
Saída analógica para alimentação. . . . . . . . . . . . . . . . . . . . . . . . . 2,6 kVAC / 300 VAC reforçada
Status de relé para alimentação. . . . . . . . . . . . . . . . . . . . . . . . . . 1,5 kVAC / 150 VAC reforçada
Interface de comunicação . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Communication enabler 4511 /
Programador frontal 4501
Dinâmicas de sinal, entrada / saída . . . . . . . . . . . . . . . . . . . . . . . . . 24 bit / 16 bit
Sinal / ruído . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Min. 60 dB (0...100 kHz)
Tempo de resposta(0...90%, 100...10%):
Temperatura de entrada, programável . . . . . . . . . . . . . . . . . . . . . . 1...60 s
mA / V entrada, programável. . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,4...60 s
Precisão, a melhor para os valores básicos e gerais:
Influência de imunidade EMC. . . . . . . . . . . . . . . . . . . . . . . < ±0,5% de span
Imunidade EMC extendida:
NAMUR NE 21, critério de explosão A . . . . . . . . . . . . . . . . . < ±1% de span
Valores gerais
Tipo entrada Precisão absoluta Coeficiente de temperatura
Todas ≤ ±0,1% de span ≤ ±0,01% de span / °C
Valores básicos
Tipo entrada Precisão básica Coeficiente de temperatura
mA ≤ ±16 μA ≤ ±1,6 μA / °C
Pt100, Pt200, Pt1000 ≤ ±0,2°C ≤ ±0,02°C / °C
Pt500, Ni100,
Ni120, Ni 1000
≤ ±0,3°C
≤ ±0,03°C / °C
Pt50, Pt400, Ni50 ≤ ±0,4°C ≤ ±0,04°C / °C
Pt250, Pt300 ≤ ±0,6°C ≤ ±0,06°C / °C
Pt20 ≤ ±0,8°C ≤ ±0,08°C / °C
Pt10 ≤ ±1,4°C ≤ ±0,14°C / °C
TC tipo:
E, J, K, L, N, T, U
≤ ±1°C
≤ ±0,1°C / °C
TC tipo:
R, S, W3, W5, LR
≤ ±2°C
≤ ±0,2°C / °C
TC tipo: B
160...400°C
≤ ±4,5°C
±0,45°C / °C
TC tipo: B
400...1820°C
≤ ±2°C
≤ ±0,2°C / °C
Tipo Descrição
Dissipação de
potência máxima
Potência necessária
máxima
9113xA 1 canal ≤ 0,8 W ≤ 0,8 W 9113xB 2 canais ≤ 1,4 W ≤ 1,4 W
9113 - Versão do produto 9113-004 11
Entrada RTD:
Entradas para tipo de RTD: Pt10*, Pt20*, Pt50*, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000 Ni50, Ni100, Ni120, Ni1000
Resistência de cabo por fio (max.) . . . . . . . . . . . . . . . . . . . . . . . . . 50 Ω
Corrente de sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nom. 0,2 mA
Efeito da resistência de cabo do sensor
(3- / 4-fios) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 0,002 Ω / Ω
Detecção de erro do sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programável ON / OFF
Corrente de erro do sensor:
quando detectado . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 2 μA
senão . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 μA
* sem detecção de curto circuito para Pt10, Pt20 e Pt50
Entrada TC:
Compensação de junta fria (CJC):
via sensor externo no conector 5910 . . . . . . . . . . . . . . . . . . . . . . 20...28°C ≤ ±1°C
-20...20°C e 28...70°C ±2°C
via sensor CJC interno. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±(2,0°C + 0,4°C * t)
t = temperatura interna - temperatura ambiente
Detecção de erro de sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ON ou OFF programável
(apenas rompimento de cabo) Erro de corrente do sensor:
quando detectado . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nom. 2 μA
senão . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 μA
Entrada de corrente:
Range de medição . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0...23 mA
Ranges de medição programáveis. . . . . . . . . . . . . . . . . . . . . . . . . . 0...20 e 4...20 mA
Resistência de entrada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nom. 20 Ω + PTC 50 Ω
Detecção de erro de sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ON / OFF programável
Apenas 4...20 mA (NAMUR)
Saída de corrente:
Range de sinal (span) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0...23 mA
Ranges de sinais programáveis . . . . . . . . . . . . . . . . . . . . . . . . . . . 0...20 / 4...20 / 20...0 e 20...4 mA
Carga. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 Ω
Estabilidade de carga . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,01% de span / 100 Ω
Detecção de erro de sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 / 3,5 / 23 mA / nenhum
NAMUR NE 43 alta escala / baixa escala . . . . . . . . . . . . . . . . . . . . . . 23 mA / 3,5 mA
Tipo RTD
Valor
mínimo
Valor
máximo
Padrão
Pt100 Ni100
-200°C
-60°C
+850°C +250°C
IEC 60751
DIN 43760
Tipo
Temperatura
mínima
Temperatura
máxima
Padrão
B E
J K L N R S T U
W3 W5
LR
0°C
-100°C
-100°C
-180°C
-200°C
-180°C
-50°C
-50°C
-200°C
-200°C 0°C 0°C
-200°C
+1820°C +1000°C +1200°C +1372°C
+900°C +1300°C +1760°C +1760°C
+400°C
+600°C +2300°C +2300°C
+800°C
IEC 60584-1 IEC 60584-1 IEC 60584-1 IEC 60584-1
DIN 43710 IEC 60584-1 IEC 60584-1 IEC 60584-1 IEC 60584-1
DIN 43710
ASTM E988-90 ASTM E988-90 GOST 3044-84
12 9113 - Versão do produto 9113-004
Limitação de saída:
em sinais 4...20 e 20...4 mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,8...20,5 mA
em sinais 0...20 e 20...0 mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0...20,5 mA
Limite de corrente . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 mA
Instalação de saída 2 fios passivo:
Alimentação externa máxima 2 fios . . . . . . . . . . . . . . . . . . . . . . . . 26 VDC
Resistência de carga máxima [Ω] . . . . . . . . . . . . . . . . . . . . . . . . . . (Valimentação - 3,5) / 0,023 A
Efeito de alimentação externa 2 fios variação de tensão . . . . . . . . . . . . < 0,005% de span / V
Status de relé em área segura:
Tensão máxima. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 VAC / 110 VDC
Corrente máxima. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,5 AAC / 0,3 ADC
Tensão AC máxima. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62,5 VA / 32 W
de span = range de medição selecionado recentemente
Determinações das autoridades observados:
EMC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2014/30/UE
LVD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2014/35/UE
RoHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2011/65/UE
Aprovações:
DNV-GL, Ships & Oshore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stand. f. Certific. No. 2.4
c UL us, Standard for Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL 61010-1
EAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TR-CU 020/2011
Aprovações I.S. / Ex:
ATEX 2014/34/UE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KEMA 07ATEX0148 X
IECEx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IECEx KEM 09.0052X
c FM us. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3038279-C
INMETRO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DEKRA 16.0003 X
CCOE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P337349/3
EAC Ex TR-CU 012/2011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RU C-DK.GB08.V.00410
Segurança Funcional:
SIL 2 Certificada & Totalmente Avaliada de acordo com IEC 615088
9113 - Versão do produto 9113-004 13
Configuração de verificação de erro do sensor
Visualização no 4511/4501 of:
Sinal de entrada fora do range
Detecção de erro do sensor
Checagem de erro de sensor:
Equipa-
mento:
Configuração Detecção de erro de sensor:
9113
OUT.ERR=NONE. OFF
Senão: ON
Fora do range de leitura (IN.LO, IN.HI):
Se o range válido do conversor A/D ou polinomial é excedido
Entrada Range Leitura Limite
CURR 0...20 mA / 4...20 mA
IN.LO < -1,05 mA
IN.HI > 25,05 mA
TEMP TC / RTD
IN.LO < range de temp. -2°C
IN.HI > range de temp. +2°C
Sensor error detection (SE.BR, SE.SH):
Entrada Range Leitura Limite
CURR Loop break (4...20 mA) SE.BR <= 3,6 mA; > = 20,75 mA
TEMP
TC SE.BR > 10 kΩ...165 kΩ
RTD: 2-, 3- e 4-fios
Para Pt10, Pt20, Pt50, Pt100, Pt200, Ni50 e
Ni120
SE.BR
> 900...1000 Ω
(cabo > 50 Ω)
SE.SH < aprox. 15 Ω
RTD: 2-, 3- e 4-fios
Para Pt250, Pt300, Pt400, Pt500, Pt1000 e
Ni1000
SE.BR
> 10...12 kΩ
(cabo > 50 Ω)
SE.SH < aprox. 15 Ω
Leitura de display abaixo . / max. (-1999, 9999):
Entrada Range Readout Limite
Todos Todos
-1999 Leitura display <-1999
9999 Leitura display >9999
14 9113 - Versão do produto 9113-004
Indicações de erro
Leitura de erro de hardware
Pesquisa de erro Leitura Causa
Erro de sensor CJC - checar a temperatura do equipamento
CJ.ER
Sensor CJC com defeito interno ou temperatura
do CJC fora do range permitido**
Erro de conector CJC - checar bloco de conector CJC
CJ.ER
Defeito (ou falha) no conector CJC ou
temperatura fora do range permitido**
Erro de entrada - verificar conexão de entrada e reiniciar o equipamento
IN.ER
Níveis de sinal na entrada além dos limites ou
conectado nos terminais errados*
Erro de saída - verificar conexão de saída e reiniciar o equipamento
AO.ER
Erro na corrente de saída analógica
(Apenas modo SIL)*
Sem comunicação NO.CO Sem comunicação com (4511/4501)
Erro de memória Flash - verificar configuração
FL.ER CO.ER
Erro de FLASH (configuração inválida)***
Versão ou tipo de configuração inválida TY.ER
Leitura de configuração da EEprom tem um
tipo inválido ou rev. no. Erro de hardware RA.ER Erro de RAM* Erro de hardware IF.ER Erro de Flash interno* Erro de hardware SW.ER Erro de monitor SW* Erro de hardware AD.ER Erro de conversor A/D* Erro de hardware AO.SU Erro de alimentação da saída analógica* Erro de hardware CA.ER Erro de calibração de fábrica*
Erro de hardware CM.ER Erro de CPU principal* Erro de hardware II.ER Erro de verificação de inicialização* Erro de hardware RS.ER Erro de reinicialização* Erro de hardware IC.ER Erro de comunicação de entrada* Erro de hardware M1.ER Erro de canal 1 da CPU principal* Erro de hardware M2.ER Erro de canal 2 da CPU principal* Erro de hardware MC.ER Erro de configuração da CPU principal*
Erro de hardware MF.ER Erro de Flash da CPU principal* Erro de hardware MR.ER Erro de RAM da CPU principal* Erro de hardware MS.ER Erro de alimentação da CPU principal* Erro de hardware MP.ER Erro de ProgFlow da CPU principal*
!
Todas as indicações de erro no display piscam uma vez por segundo (1 Hz) e o texto de ajuda correspondente é mostrado. Se o erro é um erro de sensor, a luz de fundo também pisca – isto pode ser
cancelado apertando o botão 3. * Erro é anulado através de uma reinicialização do equipamento ** Erro pode ser desconsiderado pela seleção de tipo de entrada diferente de TC. *** Erro é anulado utilizando as configurações básicas.
9113 - Versão do produto 9113-004 15
Conexões
11
1312
14
+
-
mA
11
1312
14
+
-
mA
11
1312
14
+
mA
11
1312
14
+
mA
41
4342
4441
4342
44 41
4342
44 41
4342
44
31 32 3433
91 92 93 94 95
+ - + -
51
5352
54
+
-
41
4342
44
+
-
51
5352
5451
5352
54 51
5352
54 51
5352
54
+ - + -
Alimentação
e status do relé
Conexões
trilho de tensão
N.C.
NC = no connection (sem conexão)
Aliment. -
Aliment. +
Aliment. -
Aliment. +
NC
NC
Erro
Saídas:
Transmissor 2 fios
(Saída passiva)
Corrente
(Saída ativa)
Transmissor 2 fios
(Saída passiva)
Corrente
(Saída ativa)
TC, sensor CJC
internoRTD, 3- / 4 fiosRTD, 2 fios
*TC,
Conector CJC
Canal 1
Canal 2
Canal 2
Entradas:
Canal 1
TC, sensor CJC
internoRTD, 3- / 4 fiosRTD, 2 fios
*TC,
Conector CJC
Canal 2
CorrenteCorrente
Canal 1
* Vendido separadamente: Conector CJC 5910Ex (ca. 1) / 5913Ex (ca. 2).
9113
51
31
14
32
34
33
12
11
13

100C
12 mA
*
*
I+
mA
I+
mA
54
53
52
44
43
42
41
NC*NC*
CPU
FLASH
mA
mA
-
+
-
+
-
+
-
+
234
234
16 9113 - Versão do produto 9113-004
Diagrama de bloco
Status de relé N.C.
Status de relé N.C.
RTD, conn.
cabos
Alimentação +24 VDC
Gnd.
Gnd.
Corrente
RTD, conn.
cabos TC
Corrente
Conexões Trilho de tensão
Canal 1
Canal 2
TC
Status do equipa-
mento, Verde
Status canal 1,
Vermelho
Status canal 2,
Vermelho
* NC = no connection (sem conexão)
Aliment. +
Aliment. -
Alimentação -
9113 - Versão do produto 9113-004 17
Indicações de falha de cabo e erro de sinal sem display frontal
Lista de LEDs e indicações de erro de sinal
Condição
LED
verde
Canal 1:
LED
vermelho
Canal 2:
LED
vermelho
Relé de status,
N.C..
Trilho de tensão
status de sinal
Equipamento OK Piscando OFF OFF Energizado Aberto Sem alimentação OFF OFF OFF Desenergizado Fechado Equipamento com defeito OFF ON ON Desenergizado Fechado
Ca. 1 com defeito (ca. 2 OK) Piscando ON OFF Desenergizado Fechado Ca. 2 com defeito (ca. 1 OK) Piscando OFF ON Desenergizado Fechado
Sinal de canal 1, OK Piscando OFF OFF Energizado Aberto Cabo do canal 1 em curto /
quebrado
Piscando Piscando OFF Desenergizado
Fechado
(se ativado)
Sinal de canal 2, OK Piscando OFF OFF Energizado Aberto Cabo do canal 2 em curto /
quebrado
Piscando OFF Piscando Desenergizado
Fechado
(se ativado)
18 9113 - Versão do produto 9113-004
Configuração / operando os botões de função
Documentação para diagrama de encaminhamento.
No geral
Quando configurar o 9113, você será guiado através de todos os parâmetros e você pode escolher os ajustes para colocar na aplicação. Para cara menu há textos de ajuda que são automaticamente mostrados na linha 3 do display.
Configuração pode ser realizada através de 3 botões de função: 1 irá aumentar o valor numérico ou escolher o próximo parâmetro 2 irá diminuir o valor numérico ou escolher o parâmetro anterior 3 irá aceitar o valor escolhido e seguir para o próximo parâmetro
Quando a configuração está completa, o display irá retornar para o estado padrão 1.0. Pressionando e segurando 3 irá retornar para o menu anterior ou retornar para o estado padrão (1.0) sem salvar os valores ou parâmetros alterados.
Se nenhum botão é pressionado por 1 minuto, o display irá retornar para o estado padrão (1.0) sem salvar os valores ou parâmetros alterados.
Mais explicações
Senha de proteção: O acesso à programação pode ser bloqueado atribuindo uma senha. A senha é salva no equipamento a fim
de garantir um alto nível de proteção contra modificações não autorizadas na configuração. A senha padrão 2008 permite o acesso a todos os menus de configuração.
Seleção de unidades
Após escolher o tipo de sinal de entrada você pode escolher quais unidades de processo devem ser mostradas no display (veja tabela). Pela seleção de entrada de temperatura o valor do processo é sempre mostrado em Celsius ou Fahrenheit. Isto é selecionado no ponto de menu após seleção de entrada de temperatura.
CJC
No menu CJC você pode escolher entre o conector CJC e o CJC interno. O conector CJC (Pr 5910Ex / PR 5913Ex) deve ser vendido separadamente.
Informação de erro de sensor e sinal via display frontal 4511/4501
Erro de sensor (veja limites na tabela) é mostrado como SE.BR (sensor break) ou SE.SH (sensor short). Sinais fora do range selecionado (não erro de sensor, veja tabela para limites) são mostrados como IN.LO indicando sinal de entrada baixo ou In.HI indicando sinal de entrada alto. A indicação de erro é mostrada como texto na linha 1 e ao mesmo tempo a luz de fundo pisca. A linha 4 do display é uma linha de status que mostra se o equipamento está bloqueado por SIL assim como status de relé e COM indicando o funcionamento correto do 4511/4501.
Indicação de erro de sensor e sinal sem o display frontal
Status da unidade pode também ser lida por 3 LEDs na parte frontal do equipamento. LED verde piscando indica operação normal. Sem indicação no LED verde indica falta de tensão de alimentação ou erro no equipamento. LED vermelho estável indica erro fatal. LED vermelho piscando indica erro de sensor.
Funções avançadas
A unidade dá acesso a um número de funções avançadas que podem ser alcançadas respondendo “Yes” no parâmetro “adv.set”.
Configuração de display: Aqui você pode ajustar o contrate de brilho e luz de fundo. Configuração dos números de TAG com 5 caracteres alfanuméricos. Seleção de leitura funcional na linha 2 e 3 do display – escolha entre leitura de status de saída, corrente de saída ou número de tag.
Calibração de processo de dois pontos: O equipamento pode ser calibrado em 2 pontos para ajustar um sinal de entrada fornecido. Um sinal de entrada baixo (não necessariamente 0%) é aplicado e o valor atual é colocado via 4511/4501. Depois um sinal alto (não necessariamente 100%) é aplicado e o valor atual é colocado via 4511/4501. Se você aceitar o uso da calibração, o equipamento irá trabalhar de acordo com este novo ajuste. Se depois você rejeitar este ponto do menu ou escolher outro tipo de sinal de entrada o equipamento irá retornar para a calibração de fábrica.
9113 - Versão do produto 9113-004 19
Função de simulação do processo: No ponto do menu “EN.SIM” é possível simular um sinal de entrada por meio das teclas de seta e assim controlar um sinal de saída para cima ou para baixo. Você deve sair do menu pressionando 3 (nenhum tempo limite). A função de simulação sairá automaticamente, se o 4511/4501 for destacado.
Password: Aqui você pode escolher uma senha entre 0000 e 9999 a fim de proteger o equipamento contra modificações da configuração não autorizadas. O equipamento é entregado sem uma senha padrão.
Memória: No menu de memória você pode salvar a configuração do equipamento no 4511/4501, e depois mover 4511/4501 para outro equipamento do mesmo tipo e baixar a configuração no novo equipamento.
Linguagem: No menu “LANG” você pode escolher entre 7 versões de linguagens diferentes de textos de ajuda que irão aparecer no menu. Você pode escolher entre UK, DE, FR, IT, ES, SE e DK.
Trilho: No menu “RAIL” você pode escolher se erros no módulo serão transmitidos para a central de monitoramento na unidade de controle de tensão PR 9410.
Nível de Integridade de Segurança (SIL): Veja o manual de segurança para detalhes.
0000
PASSW.
Txt 1
0000 9999
NO
ADV.SET
Txt 2
NO
YES
1 21 2
*1.1
100C
12 mA
 
YES
ADV.SET
Txt 2
NO
YES
1 2
23
OUT.ERR
Txt 13
23mA
0/3.5mA
NONE
1 2
CURR
CH1 TYPE
Txt 3
CURR TEMP
1 2
33
3
3
3
*1.0
1
4-20
I.RANGE
Txt 4
4-20 0-20
1 2
33
4-20
O.RANGE
Txt 12
20-4 20-0 4-20 0-20
1 2
C
UNIT
Txt 11
F C
1 2
3
*1.2
3
3W
CONNEC.
Txt 9
4W 3W 2W
1 2
TEMP
CH1 TYPE
Txt 3
3
Pt
SENSOR
Txt 5
Pt
Ni
TC
1 2
33
100
Pt TYPE
Txt 6
1000
-
10
1 2
3
3W
CONNEC.
Txt 9
4W 3W 2W
1 2
Ni
SENSOR
Txt 5
33
100
Ni TYPE
Txt 7
1000
-
50
1 2
3
INT
CJC
Txt 36
CONN
INT
1 2
TC
SENSOR
Txt 5
33
TC.K
TC TYPE
Txt 8
TC.Lr TC.W5 TC.W3 TC.U TC.T TC.S TC.R TC.N TC.L TC.WK TC.J TC.E
1 2
3
20 9113 - Versão do produto 9113-004
Diagrama de encaminhamento
Se nenhum botão é acionado por 1 minuto, o display irá retornar para o status padrão 1.0 sem salvar as mudanças de configuração.
1 Aumenta o valor / escolhe próximo parâmetro 2 Diminui o valor / escolhe o parâmetro anterior 3 aceita o valor escolhido e procede para o próximo menu
Segurar o 3 Volta para o menu anterior / retorna para o menu 1.0 sem salvar.
Continua na página Diagrama de encaminhamento ADV.SET
Power up
Se bloqueado por SIL
diretamente para
[EN.SIL]
*1.0
Status padrão. Linha 1 mostra status de entrada. Linha 2 e 3 mostra valor da entrada / saída ou TAG no. e unidades. Linha 4 mostra status para communicação e se o equipa­mento está bloqueado por SIL. Dot estática = Bloqueio por SIL, dot piscando = sem bloqueio-SIL.
*1.1
= Apenas se protegido por senha.
*1.2
Não válido para sinal de entrada 0...20 mA. Texto vermelho significa
parâmetros de segurança em configuração SIL. Veja o manual de segurança para detalhes.
*1.3
Apenas se o sinal de entrada é temperatura. Min. e max. acc. para tipo de sensor selecion
*1.4
Apenas se a configuração não está protegida por uma senha.
Loading...
+ 44 hidden pages