PR Elecronics 5714 User Manual

5714
Programmable LED Indicator
No. 5714V103-UK From serial number: 121496001 (A+B) 131077001 (C+D)
1651
PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere, Universaltransmittere mfl. Vi har modulerne, du kan stole på i selv barske miljøer med elektrisk støj, vibrationer og temperaturudsving, og alle produkter opfylder de strengeste internationale standarder. Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet.
PR electronics A/S oers a wide range of analog and digital signal conditioning devices for industrial automation. The product range includes Isolators, Displays, Ex Interfaces, Temperature Transmitters, and Universal Devices. You can trust our products in the most extreme environments with electrical noise, vibrations and temperature fluctuations, and all products comply with the most exacting international standards. »Signals the Best« is the epitome of our philosophy – and your guarantee for quality.
PR electronics A/S ore une large gamme de produits pour le traite ment des signaux analogiques et numériques dans tous les domaines industriels. La gamme de produits s’étend des transmetteurs de température aux acheurs, des isolateurs aux interfaces SI, jusqu’aux modules universels. Vous pouvez compter sur nos produits même dans les conditions d’utilisation sévères, p.ex. bruit électrique, vibrations et fluctuations de température. Tous nos produits sont conformes aux normes internationales les plus strictes. Notre devise »SIGNALS the BEST« c’est notre ligne de conduite - et pour vous l’assurance de la meilleure qualité.
PR electronics A/S verfügt über ein breites Produktprogramm an analogen und digitalen Signalverarbeitungsgeräte für die in­dustrielle Automatisierung. Dieses Programm umfasst Displays, Temperaturtransmitter, Ex- und galvanische Signaltrenner, und Universalgeräte. Sie können unsere Geräte auch unter extremen Einsatzbedingungen wie elektrisches Rauschen, Erschütterungen und Temperaturschwingungen vertrauen, und alle Produkte von PR electronics werden in Überein stimmung mit den strengsten internationalen Normen produziert. »Signals the Best« ist Ihre Garantie für Qualität!
DK
UK
FR
DE
5714V103-UK 1
PROGRAMMABLE LED INDICATOR
PREVIEW 5714
TABLE OF CONTENTS
Warning ....................................................................................................... 2
Symbol identification ............................................................................ 2
Safety instructions ................................................................................. 3
Front and back layout ........................................................................... 5
Application ................................................................................................. 6
Technical characteristics ...................................................................... 6
Mounting .................................................................................................... 6
Applications............................................................................................... 7
Order: 5714 ............................................................................................... 8
Electrical specifications........................................................................ 8
Sensor error detection /
sensor error detection outside range ......................................... 12
Connections .............................................................................................. 14
Block diagram ........................................................................................... 15
Routing diagram ...................................................................................... 17
Scrolling help text .................................................................................. 18
Configuration / operating the function keys ............................... 20
Graphic depiction of the relay function setpoint....................... 21
2 5714V103-UK
SYMBOL IDENTIFICATION
Triangle with an exclamation mark: Warning / demand. Potentially
lethal situations.
The CE mark proves the compliance of the device with the essen­tial requirements of the directives.
WARNING
This device is designed for connection to hazardous electric vol­tages. Ignoring this warning can result in severe personal injury or mechanical damage. To avoid the risk of electric shock and fire, the safety instructions of this manual must be observed and the guidelines followed. The specifications must not be exceeded, and the device must only be applied as described in the follo­wing. Prior to the commissioning of the device, this manual must be examined carefully. Only qualified personnel (technicians) should install this device. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
WARNING
Until the device is fixed, do not connect hazardous voltages to the device. The following operations should only be carried out on a discon­nected device and under ESD safe conditions: Troubleshooting the device.
Repair of the device must be done by PR electronics A/S only.
GENERAL
HAZARD -
OUS
VOLTAGE
5714V103-UK 3
SAFETY INSTRUCTIONS
DEFINITIONS:
Hazardous voltages have been defined as the ranges: 75 to 1500 Volt DC, and 50 to 1000 Volt AC. Technicians are qualified persons educated or trained to mount, operate, and also troubleshoot technically correct and in accordance with safety regulations. Operators, being familiar with the contents of this manual, adjust and operate the knobs or potentiometers during normal operation.
RECEIPT AND UNPACKING:
Unpack the device without damaging it. The packing should always follow the device until this has been permanently mounted. Check at the receipt of the device whether the type corresponds to the one ordered.
ENVIRONMENT:
Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock, as well as rain and heavy moisture. If necessary, heating in excess of the stated limits for ambient temperatures should be avoided by way of ventilation. All devices fall under Installation Category II, Pollution Degree 1, and Insulation Class II.
MOUNTING:
Only technicians who are familiar with the technical terms, warnings, and instruc­tions in the manual and who are able to follow these should connect the device. Should there be any doubt as to the correct handling of the device, please con­tact your local distributor or, alternatively,
PR electronics A/S
www.prelectronics.com.
Mounting and connection of the device should comply with national legislation for mounting of electric materials, i.a. wire cross section, protective fuse, and location. Descriptions of Input / Output and supply connections are shown in the block diagram and side label.
4 5714V103-UK
The following apply to fixed hazardous voltages-connected devices:
The max. size of the protective fuse is 10 A and, together with a power switch, it should be easily accessible and close to the device. The power switch should be marked with a label telling it will switch off the vol­tage to the device.
UL INSTALLATION REQUIREMENTS:
For use on a flat surface of a type 1 enclosure Use 60/75°C copper conducters only
Enclosure rating (face only)........................... Type 4X, UL50E
Max. ambient temperature ............................ 60°C
Max. wire size, pins 41...46 ........................... AWG 30-16
Max. wire size, others ...................................... AWG 30-12
UL file number .................................................... E248256
CALIBRATION AND ADJUSTMENT:
During calibration and adjustment, the measuring and connection of external voltages must be carried out according to the specifications of this manual. The technician must use tools and instruments that are safe to use.
NORMAL OPERATION:
Operators are only allowed to adjust and operate devices that are safely fixed in panels, etc., thus avoiding the danger of personal injury and damage. This means there is no electrical shock hazard, and the device is easily accessible.
CLEANING:
When disconnected, the device may be cleaned with a cloth moistened with distilled water.
LIABILITY:
To the extent the instructions in this manual are not strictly observed, the custom er cannot advance a demand against PR electronics A/S that would other­wise exist according to the concluded sales agreement.
5714V103-UK 5
FRONT AND BACK LAYOUT
Picture 1: Front of PReview 5714.
Picture 2: Back of PReview 5714.
6 5714V103-UK
PROGRAMMABLE LED INDICATOR
PREVIEW 5714
4-digit 14-segment LED indicator
Input for mA, V, potentiometer, Ohm, RTD and TC
2 relays and analogue output
Universal voltage supply
Front key programmable
Application
• Display for digital readout of current, voltage, resistance, temperature or potentiometer signals.
• Process control with 2 pairs of potential-free relays and / or analogue output.
• For local readout in extremely wet atmospheres with a specially designed splash-proof cover.
Technical characteristics
• 4-digit LED indicator with 13.8 mm 14-segment characters. Max. display read­out -1999...9999 with programmable decimal point, relay ON / OFF indication.
• All operational parameters can be adjusted to any application by use of the front keys.
• PReview 5714 is available fully-configured acc. to specifications ready for process control and visualisation.
• Help texts in eight languages can be selected via a menu item.
• In versions with relay outputs the user can minimise the installation test time by activating / deactivating each relay independently of the input signal.
Mounting
• To be mounted in front panel. The included rubber packing must be mounted between the panel cutout hole and the display front to obtain a protection degree of IP65 (type 4X). For extra protection in extreme environments, PReview 5714 can be delivered with a speially designed splash-proof cover as accessory.
12
11
26
25
24
23
22
21
1 2
32
31
1 2
46
45
44
43
42
41
4 3 2
TC
1 2
-
+
-
+
-
+
-
+
-
+
5714V103-UK 7
APPLICATIONS
Input signals:
Current
Poten-
tio meter
Output signals:
2 change over relays
Analogue, 0/4...20 mA
Supply:
21.6...253 VAC or
19.2...300 VDC
Voltage
RTD & Lin R -
connection, wires
2-wire transmitter
8 5714V103-UK
NB! Please order the splash-proof cover seperately. Order No. 8335.
Electrical specifications
Specifications range:
-20°C to +60°C
Common specifications:
Supply voltage, universal ..................................... 21.6...253 VAC, 50...60 Hz or
19.2...300 VDC
Consumption
Isolation voltage, test / operation ................... 2.3 kVAC / 250 VAC
Signal- / noise ratio ................................................ Min. 60 dB (0...100 kHz)
Response time (0...90 %, 100...10 %), programmable:
Temperature input .......................................... 1...60 s
Current / voltage input ................................. 0.4...60 s
Calibration temperature ....................................... 20...28°C
Accuracy, the greater of general and basic values:
General values
Input type
Absolute
accuracy
Temperature
coefficient
All ±0.1% of reading ±0.01% of reading / °C
Type Internal consumption Max. consumption
5714A 2.2 W 2.5 W
5714B/C 2.7 W 3.0 W
5714D 3.2 W 3.5W
Type Version
5714 Standard.......................: A
2 relays........................: B
Analogue output ...............: C
Analogue output and 2 relys....: D
Order: 5714
5714V103-UK 9
Auxiliary supply:
2 wire supply, pin 46...45 ............................. 25...15 VDC / 0...20 mA
Vibration ...................................................................... IEC 60068-2-6 Test FC
2...13.2 Hz ........................................................... ±1 mm
13.2...100 Hz ..................................................... ±0.7 g
Wire size, pin 41...46 max. .................................. 1 x 1.5 mm
2
stranded wire
Wire size, others max. ........................................... 1 x 2.5 mm
2
stranded wire
Relative humidity..................................................... < 95% RH (non cond.)
Dimensions (HxWxD) .............................................. 48 x 96 x 120 mm
Cutout dimensions .................................................. 44.5 x 91.5 mm
Protection degree (mounted in panel) ............ IP65 / Type 4X, UL50E
Weight .......................................................................... 230 g
RTD, linear resistance and potentiometer input:
Basic values
Input
type
Basic
accuracy
Temperature
coefficient
mA ±4 µA ±0.4 µA / °C
Volt ±20 µV ±2 µV / °C
Pt100 ±0.2°C ±0.01°C / °C
Linear resistance ±0.1 Ω ±0.01 Ω / °C
Potentiometer ±0.1 Ω ±0.01 Ω / °C
TC type:
E, J, K, L, N, T, U
±1°C
±0.05°C / °C
TC type: R, S, W3,
W5, LR
±2°C
±0.2°C / °C
TC type: B
85...200°C
±4°C
±0.4°C / °C
TC type: B
200...1820°C
±2°C
±0.2°C / °C
Input
type
Min.
value
Max.
value
Standard
Pt10...Pt1000
Ni50...Ni1000
Cu10...Cu100
Lin. R
Potentiometer
-200°C
-60°C
-200°C 0 Ω
10 Ω
+850°C +250°C +260°C
10000 Ω
100 kΩ
IEC 60751
DIN 43760
α = 0.00427
-
-
EMC immunity influence .................................... < ±0.5% of readout
10 5714V103-UK
Input for RTD types: Pt10, Pt20, Pt50, Pt100, Pt200, PT250, Pt300, Pt400, Pt500, Pt1000 Ni50, Ni100, Ni120, Ni1000, Cu10, Cu20, Cu50, Cu100
Cable resistance pr. wire, RTD (max.) .............. 50 Ω
Sensor current, RTD ................................................ Nom. 0.2 mA
Effect of sensor cable resistance
(3- / 4-wire), RTD ..................................................... < 0.002 Ω / Ω
Sensor error detection, RTD ................................ Yes
Short curcuit detection, RTD ............................... < 15 Ω
TC input:
Cold junction compensation (CJC)
via internal sensor ........................................... ±(2.0°C + 0.4°C * Δt)
Δt = internal temperature - ambient temperature
Sensor error detection, all TC types................. Yes
Sensor error detection ........................................... Yes
Sensor error current:
when detecting ................................................. Nom. 2 μA
else ......................................................................... 0 μA
Current input:
Measurement range ................................................ 0...20 mA
Programmable measurement ranges ............... 0...20 and 4...20 mA
Input resistance........................................................ Nom. 20 Ω + PTC 25 Ω
Sensor error detection:
loop break 4...20 mA ....................................... Yes
Type
Min.
value
Max.
value
Standard
B E
J
K
L N R S T U
W3 W5
LR
0°C
-100°C
-100°C
-180°C
-200°C
-180°C
-50°C
-50°C
-200°C
-200°C 0°C 0°C
-200°C
+1820°C +1000°C +1200°C +1372°C
+900°C +1300°C +1760°C +1760°C
+400°C
+600°C +2300°C +2300°C
+800°C
IEC 60584-1 IEC 60584-1 IEC 60584-1 IEC 60584-1
DIN 43710 IEC 60584-1 IEC 60584-1 IEC 60584-1 IEC 60584-1
DIN 43710
ASTM E988-90 ASTM E988-90 GOST 3044-84
5714V103-UK 11
Voltage input:
Measurement range ................................................ 0...12 VDC
Programmable measurement ranges ............... 0...1 / 0.2...1 /
0...10 / 2...10 VDC
Input resistance........................................................ Nom. 10 MΩ
Outputs: Display:
Display readout......................................................... -1999...9999 (4 digits)
Decimal point ............................................................. Programmable
Digit height ................................................................ 13.8 mm
Display updating ...................................................... 2.2 times / s
Input outside input range is
indicated by................................................................ Explanatory text
Current output:
Signal range (span) ................................................. 0...20 mA
Programmable signal ranges ............................... 0...20 / 4...20 /
20...0 / 20...4 mA
Load (max.) ................................................................. 20 mA / 800 Ω / 16 VDC
Load stability ............................................................. 0.01% of span / 100 Ω
Sensor error detection ........................................... 0 / 3.5 / 23 mA / none &
NAMUR NE 43 up / downscale ........................... 23 mA / 3.5 mA
Output limitation:
on 4...20 and 20...4 mA signals .................. 3,8...20.5 mA
on 0...20 and 20...0 mA signals .................. 0...20.5 mA
Current limit ............................................................... 28 mA
Relay outputs:
Relay function ........................................................... Setpoint
Hysteresis ................................................................... 0...100%
On and Off delay ...................................................... 0...3600 s
Sensor error detection ........................................... Make / Break / Hold
Max. voltage .............................................................. 250 VRMS
Max. current ............................................................... 2 A / AC
Max. AC power .......................................................... 500 VA
Max. current at 24 VDC ......................................... 1 A
Marine approval:
Det Norske Veritas, Ships & Offshore ............. Standard for Certification No. 2.4
Observed authority requirements: Standard:
EMC 2004/108/EC .................................................. EN 61326-1
LVD 2006/95/EC ...................................................... EN 61010-1
UL, Standard for Safety ......................................... UL 508
EAC TR-CU 020/2011 ............................................ EN 61326-1
12 5714V103-UK
Sensor error detection / sensor error detection outside range
Sensor error check in 5714 variants
Variant: Configuration Sensor error detection:
5714A Always: ON
5714B
ERR1=NONE, ERR2=NONE: OFF
else: ON
5714C
O.ERR=NONE: OFF
else: ON
5714D
ERR1=NONE, ERR2=NONE, O.ERR=NONE: OFF
else: ON
Outside range readout (IN.LO, IN.HI):
If the valid range of the A/D converter or the polynomial is exceeded
Input Range Readout Limit
VOLT
0...1 V / 0,2...1 V
IN.LO < -25 mV
IN.HI > 1,2 V
0...10 V / 2...10 V
IN.LO < -25 mV
IN.HI > 12 V
CURR 0...20 mA / 4...20 mA
IN.LO < -1,05 mA
IN.HI > 25,05 mA
POTM -
IN.LO < -0,5%
IN.HI > 100,5%
TEMP TC / RTD
IN.LO < temperature range -2°C
IN.HI > temperature range +2°C
LIN R
0...800 ohm
IN.LO < 0 ohm
IN.HI > 1 kohm
0...10 kohm
IN.LO < 0 ohm
IN.HI > 15 kohm
Sensor error detection (SE.BR, SE.SH):
Input Range Readout Limit
CURR Loop break (4..20mA) SE.BR <= 3,6 mA; > = 21 mA
TEMP
TC SE.BR > ca. 750 kohm / (1,25 V)
RTD, 2-, 3- & 4-wire
No SE.SH for Cuxx, Pt10, Pt20 & Pt50
SE.BR > 12 kohm SE.SH < 15 ohm
LIN R
0...800 ohm SE.BR > 875 ohm
0...10 kohm SE.BR > 12 kohm
Display readout below min. / above max. (-1.9.9.9, 9.9.9.9):
Input Range Readout Limit
CURR
VOLT
All
-1.9.9.9 Display readout <-1999
9.9.9.9 Display readout >9999
LIN R All
-1.9.9.9 Display readout <-1999
9.9.9.9 Display readout >9999
POTM -
-1.9.9.9 Display readout <-1999
9.9.9.9 Display readout >9999
5714V103-UK 13
Readout at hardware error
Error search Readout Error cause Test of internal communication uC / ADC HW.ER Permanent error in ADC Test of internal CJC sensor CJ.ER CJC sensor defect Check-sum test of the configuration in RAM RA.ER Error in RAM Check-sum test of the configuration in EEPROM EE.ER Error in EEPROM
! Error indications in the display blink once a second. The help text explains the error.
Tx
31 32
41 42 43 44 45 4641 42 43 44 45 4641 42 43 44 45 46
41 42 43 44 45 46 41 42 43 44 45 46 41 42 43 44 45 46
41 42 43 44 45 46 41 42 43 44 45 46
mA
11 12
R2
R1
21 22 23 24 25 26
- +
- +- + - +
- +
14 5714V103-UK
CONNECTIONS
RTD & Lin R, 2-wire RTD & Lin R, 3-wire RTD & Lin R, 4-wire
PotentiometerVoltage
TC 2-wire transmitter Current
Current Relays
Inputs:
Output:
Supply:
I+
11
12
31
32
CPU
AD
EEPROM
PTC
20 Ω
5714
1 2 3 4
46
45
44
43
42
41
+V
4 3 2
2122232425
26
R1
R2
1
3
2
Tx
+
+
+
mA
5714V103-UK 15
BLOCK DIAGRAM
I
Output
Common
Relay 1 N.O.
Relay 1 N.C.
Common
Relay 2 N.O.
Relay 2 N.C.
Supply
Supply
21.6...253 VACor19.2...300 VDC
Version D
Int.
CJC
2-wire supply
> 15 VDC
Input +,
mA
Input gnd.
RTD & Lin R,
wires
Potm.
Power up
50.0
3
F.SET
REL1 REL2
3
1.0
1.2
1 2
1 2
SETP
-1999 9999
/OFF
3
1 2
DI.LO PERC
DI.HI
1.1
0000 9999
1 2
3
CURR
3
RANG
0-20 4-20
1 2
VOLT
3
RANG
1 2
0-1 0.2-1
0-10 2-10
IN
1 2
DEC.P
1111
1.1.1.1
1 2
POTM
TEMP
TYPE
PASS
3
a999 9999
1 2
3
a999 9999
1 2
3
PERC DISP
1 2
3
1.3
DEC.P
1111
111.1
1 2
UNIT
'C 'F
1 2
ADV
NO
YES
1 2
3
3
LIN.R
3
LR.LO
0-9998
1 2
LR.HI
1-9999
1 2
CONN
1 2
2W 3W 4W
3
3
3
CU.TY CONN
CU
3
1 2 1 2
10-100
2W 3W 4W
3
3
1 2
3
3
3
3
3
1.4
1.4
1.6
ADV.SET
YES
PT.TY
TC
CONN
TC.TY
PT
3
1 2 1 2
NI
NI.TY CONN
50-1000
1 2
2W 3W 4W
1 2
1 2
3
3
3
TC.B-E-J-K-L-N-R
S-T-U-W3-W5-LR
10-1000
2W 3W 4W
3
3
3
3
16 5714V103-UK
1.0 = Default state
1.1 = Only if password­protected
1.2 = Only is FastSet is enabled
1.3 = FastSet and relay test disab­led at password 5000...9999.
1.4 = No relay outputs
1.5 = Not valid for these input signals: Potentiometer, 0...20 mA and voltage
1.6 = No analogue output
1.7 = Only if input signal is temperature
1.8 = In default state press and hold
1 or 2 to change
display intensity between damped and full (7 = full intensity).
Fast setpoint adjustment
and relay test
1 Increase setpoint 2 Decrease setpoint 3 Save and exit the menu 1 and 2 simultaneously = change relay state
REL.1
SET
SKIP
OFF
1 2
3
SETP
0.0
100.0
1 2
3
ACT1
INCR DECR
1 2
3
HYS1
0.0
100.0
1 2
3
ERR1
HOLD ACTI DEAC NONE
1 2
3
ON.DE
0000 3600
1 2
3
OF.DE
0000 3600
1 2
3
3
1.5
REL.2
SET
SKIP
OFF
1 2
3
SETP
0.0
100.0
1 2
3
ACT2
INCR DECR
1 2
3
HYS2
0.0
100.0
1 2
3
ERR2
HOLD ACTI DEAC NONE
1 2
3
ON.DE
0000 3600
1 2
3
OF.DE
0000 3600
1 2
3
3
1.5
A.OUT
4-20 0-20 20-4 20-0
1 2
3
O.LO
a999 9999
1 2
3
O.HI
a999 9999
1 2
3
O.ERR
0/3.5mA
23mA NONE
1 2
3
RESP
0.0
60.0
1 2
3
E.PAS
YES
NO
1 2
3
N.PAS
0000 9999
1 2
3
NO
----
1.51.7 1.7
1.6
1.6
DE DK ES FR IT SE UK CZ
1.4
ADV.SET
LANG
DISP
CAL
1.8
7
LIGH
3
1...7
1 2
LANG
DISP
CAL
1 2
3
3
UK
HLP.T
1 2
3
YES
CA.LO
3
YES NO
1 2
2.0
VAL.L
3
100.0
0.0
1 2
NO
3
YES
CA.HI
3
1 2
90.0
VAL.H
3
100.0
0.0
1 2
NO
YES
USE.C
3
1 2
YES NO
YES NO
5714V103-UK 17
ROUTING DIAGRAM
If no keys are activated for 2 minutes the display returns to default state
1.0 without saving configuration changes..
1 Increase value / choose next parameter 2 Decrease value / choose previous parameter 3 Accept the chosen parameter and go to the next menu
Hold 3 Back to previous menu / return to menu 1.0 without saving
To default state 1.0
18 5714V103-UK
SCROLLING HELP TEXT
Display in default state xxxx, hardware error: SE.BR --> SENSOR WIRE BREAKAGE SE.SH --> SENSOR SHORT CIRCUIT IN.HI --> INPUT OVERRANGE IN.LO --> INPUT UNDERRANGE
9.9.9.9 --> DISPLAY OVERRANGE
-1.9.9.9 --> DISPLAY UNDERRANGE HW.ER --> HARDWARE ERROR EE.ER --> EEPROM ERROR -
CHECK CONFIGURATION
RA.ER --> RAM MEMORY ERROR CJ.ER --> CJC SENSOR ERROR
Fastset (Enabled): F.SET REL1 --> FAST SET MENU - REL2 --> SELECT RELAY
SETP
xxxx --> RELAY SETPOINT - PRESS OK TO SAVE
Fastset (Disabled): SETP
xxxx --> RELAY SETPOINT - READ ONLY
Configuration menus: ADV
YES --> ENTER ADVANCED SETUP MENU? NO
PASS xxxx --> SET CORRECT PASSWORD
IN C.LIN* --> TEXT ENTERED BY USER IN PRESET CURR --> CURRENT INPUT VOLT --> VOLTAGE INPUT POTM --> POTENTIOMETER INPUT LIN.R --> LINEAR RESISTANCE INPUT TEMP --> TEMPERATURE SENSOR INPUT
RANG When current selected:
0-20 --> INPUT RANGE IN mA 4-20 --> INPUT RANGE IN mA
RANG When voltage selected:
0-10 --> INPUT RANGE IN VOLT 2-10 --> INPUT RANGE IN VOLT
0.0-1 --> INPUT RANGE IN VOLT
0.2-1 --> INPUT RANGE IN VOLT
DEC.P 1111 --> DECIMAL POINT POSITION
111.1 --> DECIMAL POINT POSITION
11.11 --> DECIMAL POINT POSITION
1.111 --> DECIMAL POINT POSITION
LR.LO xxxx --> SET RESISTANCE VALUE LOW
LR.HI xxxx --> SET RESISTANCE VALUE HIGH
DI.LO xxxx --> DISPLAY READOUT LOW
DI.HI xxxx --> DISPLAY READOUT HIGH
REL.U PERC --> SET RELAY IN PERCENTAGE DISP --> SET RELAY IN DISPLAY UNITS
TYPE CU --> SELECT CU SENSOR TYPE PT --> SELECT PT SENSOR TYPE NI --> SELECT NI SENSOR TYPE TC --> SELECT TC SENSOR TYPE
CU.TY 10 --> SELECT CU SENSOR TYPE 20 --> SELECT CU SENSOR TYPE 50 --> SELECT CU SENSOR TYPE 100 --> SELECT CU SENSOR TYPE
PT.TY 10 --> SELECT PT SENSOR TYPE 20 --> SELECT PT SENSOR TYPE 50 --> SELECT PT SENSOR TYPE 100 --> SELECT PT SENSOR TYPE 200 --> SELECT PT SENSOR TYPE 250 --> SELECT PT SENSOR TYPE 300 --> SELECT PT SENSOR TYPE 400 --> SELECT PT SENSOR TYPE 500 --> SELECT PT SENSOR TYPE 1000 --> SELECT PT SENSOR TYPE
NI.TY 50 --> SELECT NI SENSOR TYPE 100 --> SELECT NI SENSOR TYPE 120 --> SELECT NI SENSOR TYPE 1000 --> SELECT NI SENSOR TYPE
CONN When Cu, Pt and Ni sensor is selected 2W --> SELECT 2-WIRE SENSOR CONNECTION 3W --> SELECT 3-WIRE SENSOR CONNECTION 4W --> SELECT 4-WIRE SENSOR CONNECTION
TC.TY TC. B --> SELECT TC SENSOR TYPE TC. E --> SELECT TC SENSOR TYPE TC. J --> SELECT TC SENSOR TYPE TC. K --> SELECT TC SENSOR TYPE TC. L --> SELECT TC SENSOR TYPE TC. N --> SELECT TC SENSOR TYPE TC. R --> SELECT TC SENSOR TYPE TC. S --> SELECT TC SENSOR TYPE TC. T --> SELECT TC SENSOR TYPE TC. U --> SELECT TC SENSOR TYPE TC.W3 --> SELECT TC SENSOR TYPE TC.W5 --> SELECT TC SENSOR TYPE TC.LR --> SELECT TC SENSOR TYPE
DEC.P When temperature selected 1111 --> DECIMAL POINT POSITION
111.1 --> DECIMAL POINT POSITION
UNIT °C --> DISPLAY AND RELAY SETUP IN CELSIUS °F --> DISPLAY AND RELAY SETUP IN FAHRENHEIT
5714V103-UK 19
REL1 SET --> ENTER RELAY 1 SETUP SKIP --> SKIP RELAY 1 SETUP OFF --> RELAY 1 DISABLED
SETP xxxx --> RELAY SETPOINT
ACT1 INCR --> ACTIVATE AT INCREASING SIGNAL DECR --> ACTIVATE AT DECREASING SIGNALL
HYS1 xxxx --> RELAY HYSTERESIS
ERR1 HOLD --> HOLD RELAY AT ERROR ACTI --> ACTIVATE RELAY AT ERROR DEAC --> DEACTIVATE RELAY AT ERROR NONE --> UNDEFINED STATUS AT ERROR
ON.DE xxxx --> RELAY ON-DELAY IN SECONDS
OF.DE xxxx --> RELAY OFF-DELAY IN SECONDS
REL2 SET --> ENTER RELAY 2 SETUP SKIP --> SKIP RELAY 2 SETUP OFF --> RELAY 2 DISABLED
SETP xxxx --> RELAY SETPOINT
ACT2 INCR --> ACTIVATE AT INCREASING SIGNAL DECR --> ACTIVATE AT DECREASING SIGNAL
HYS2 xxxx --> RELAY HYSTERESIS
ERR2 HOLD --> HOLD RELAY AT ERROR ACTI --> ACTIVATE RELAY AT ERROR DEAC --> DEACTIVATE RELAY AT ERROR NONE --> UNDEFINED STATUS AT ERROR
ON.DE xxxx --> RELAY ON-DELAY IN SECONDS
OF.DE xxxx --> RELAY OFF-DELAY IN SECONDS
A.OUT 0-20 --> OUTPUT RANGE IN mA 4-20 --> OUTPUT RANGE IN mA 20-0 --> OUTPUT RANGE IN mA 20-4 --> OUTPUT RANGE IN mA
O.LO xxxx --> DISPLAY VALUE FOR OUTPUT LOW
O.HI xxxx --> DISPLAY VALUE FOR OUTPUT HIGH
O.ERR 23 mA --> NAMUR NE43 UPSCALE AT ERROR 3,5 mA --> NAMUR NE43 DOWNSCALE AT ERROR 0mA --> DOWNSCALE AT ERROR NONE --> UNDEFINED OUTPUT AT ERROR
RESP xxx.x --> ANALOGUE OUTPUT RESPONSE TIME IN SECONDS
E.PAS NO --> ENABLE PASSWORD PROTECTION YES
N.PAS xxxx --> SELECT NEW PASSWORD
ADV MENU: LANG --> ENTER LANGUAGE SETUP DISP --> ENTER DISPLAY SETUP CAL --> PERFORM PROCESS CALIBRATION
HLP.T DE --> DE - WAEHLE DEUTSCHEN HILFETEXT DK --> DK - VAELG DANSK HJAELPETEKST ES --> ES - SELECCIONAR TEXTO DE AYUDA EN ESPANOL FR --> FR - SELECTION TEXTE D’AIDE EN FRANCAIS IT --> IT - SELEZIONARE TESTI DI AIUTO ITALIANI SE --> SE - VALJ SVENSK HJALPTEXT UK --> UK - SELECT ENGLISH HELPTEXT CZ --> CZ - VYBER CESKOU NAPOVEDU
LIGH
xxxx --> ADJUST DISPLAY LIGHT INTENSITY
CA.LO YES --> CALIBRATE INPUT LOW TO PROCESS VALUE? NO
CA.HI YES --> CALIBRATE INPUT HIGH TO PROCESS VALUE? NO
VAL.L xxxx --> SET VALUE FOR LOW CALIBRATION POINT
VAL.H xxxx --> SET VALUE FOR HIGH CALIBRATION POINT
USE.C YES --> USE PROCESS CALIBRATED VALUES? NO
20 5714V103-UK
CONFIGURATION / OPERATING THE
FUNCTION KEYS
Documentation for routing diagram.
In general:
When configuring the display you are guided through all parameters, you can
choose the settings which fit the application. For each menu there is a scrol­ling help text which is automatically shown in the display, this starts after 5 seconds if no key has been activated.
Configuration is carried out by using the 3 function keys.
1 will increase the numerical value or choose the next parameter. 2  will decrease the numerical value or choose the previous parameter. 3 will accept the chosen value and end the menu.
If a function does not exist in the display all parameters are skipped to make the
configuration as simple as possible. Once the configuration has been entered the display will show “----”. Pressing and holding
3 will return to the previous menu or return to the default
state (1.0) without saving the changed values or parameters. If no key is activated for 2 minutes, the display will return to the default state
(1.0) without saving the changed values or parameters.
Further explanations:
Fast setpoint adjustment and relay test: These menus allow you to change the
set point quickly and to check the operation of the relays. Pressing
1 and 2 at the same time will change the state of the relay – this change
is indicated by the diodes on the display. Pressing
3 will save the set point
change. Holding down
3 for more than 0.5 seconds will return the unit to the default sta-
te without changing the set point.
Password protection:
Using a password will stop access to the menu and parameters. There are two
levels of password protection. Passwords between 0000…4999 allow access to
the fast set point adjustment and relay test. (Using this password stops access
to all other parts of the menu). Passwords between 5000…9999 stop access
to all parts of the menu, fast set point and relay test. (Current set point is still
shown). By using the master password 2008, all configuration menus are avai-
lable.
100
90
80
70
60
50
40
30
20
10
0 10 20 30 40 50 60 70 80 90 100
t
O N.O. O N.O.On N.O.
On N.C. On N.C.
O N.C.
100
90
80
70
60
50
40
30
20
10
0 10 20 30 40 50 60 70 80 90 100
t
O N.O. O N.O.On N.O.
On N.C. On N.C.
O N.C.
5714V103-UK 21
Graphic depiction of the relay function setpoint
Relay unitsRelay units
Setpoint = 50
Hysteresis = 10
Hysteresis = 10
Setpoint = 50
Relay action: Increasing Relay action: Decreasing
Programmable displays with a wide selection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearization, scaling, and dierence measurement functions for programming via PReset software.
Displays
A wide selection of transmitters for DIN form B mounting and DIN rail devices with analog and digital bus communication ranging from application-specific to universal transmitters.
Temperature
Galvanic isolators for analog and digital signals as well as HART
®
signals. A wide product range with both loop­powered and universal isolators featuring linearization, inversion, and scaling of output signals.
Isolation
Interfaces for analog and digital signals as well
as HART
®
signals between sensors / I/P converters / frequency signals and control systems in Ex zone 0, 1 & 2 and for some devices in zone 20, 21 & 22.
Ex interfaces
PC or front programmable devices with universal options for input, output and supply. This range oers a number of advanced features such as process calibration, linearization and auto-diagnosis.
Universal
Head oce
Denmark www.prelectronics.com
PR electronics A/S sales-dk@prelectronics.com Lerbakken 10 tel. +45 86 37 26 77 DK-8410 Rønde fax +45 86 37 30 85
www.prelectronics.fr sales-fr@prelectronics.com
www.prelectronics.de sales-de@prelectronics.com
www.prelectronics.es sales-es@prelectronics.com
www.prelectronics.it sales-it@prelectronics.com
www.prelectronics.se sales-se@prelectronics.com
www.prelectronics.com sales-uk@prelectronics.com
www.prelectronics.com sales-us@prelectronics.com
www.prelectronics.cn sales-cn@prelectronics.com
www.prelectronics.be sales-be@prelectronics.com
Loading...