AFV variable frequency power supply User Manual
Safety instructions
Danger
Dangerous high voltages exist inside this machine. Do not open any covers of this machine unless authorized
and done by trained technicians. Otherwise, electrical shock to persons may happen.
In case the machine needs to be moved or re-wired, all electricity to the machine must be disconnected and
removed. After electricity is removed, please wait for at least 20 minutes before touching any live parts of this
machine or electrical shock may occur: the electrical charges on the bulky capacitors inside the machine need some
time to be fully discharged.
For optimal safety protection to the users, this machine must have solid connections to the earth. Do not use
this machine if it is not grounded.
In case of fire, use an extinguisher with powder chemicals instead of liquid agents. Electrical shock may occur
if liquid extinguishing products are used.
Any foreign objects and/or liquid are strictly prohibited from entering to the inside of this machine.
Caution
Storage and operating environment have a certain degree of influence on the life and reliability of this product.
Therefore, avoid placing and/or operating this machine in environments with the following:
(i). Having extreme ambient temperature or humidity that exceeds the allowable limit stated in the
specification, temperature: 0℃~45℃, humidity: 0~90%.
(ii). Having direct sunlight exposure, or being near a heat source.
(iii). Places that tend to be vibrated or hit by other objects.
(iv). Having heavy dust, heavy salt, corrosive chemicals or inflammable chemicals in the air.
Please keep air ventilation inlets and outlets clear and clean. Obstruction on the inlet or outlet will have
significant negative impact on the machine’s quality and reliability.
If the machine will not be used for a long time, please store it in a dry and clean environment with temperature
in the range of -40℃~+70℃.
Caution
i
This machine is composed of many delicate and precision devices. Please do not open any covers of this
machine unless authorized and done by trained technicians. Warranty is voided if the quality seal is broken.
AFV variable frequency power supply User Manual
Contents
Chapter I Product Introduction .................................................................................................... 1
Chapter II Working Principle ....................................................................................................... 2
2.1 Functional block diagram of complete machine ................................................................ 2
2.2 Description of functional block diagram ............................................................................ 3
2.3 Constitution of main control circuit .................................................................................... 3
Chapter III Transportation and Installation ............................................................................... 4
5.3.2 User mode ........................................................................................................................................... 21
5.4.1 General mode ..................................................................................................................................... 22
5.4.5 System maintemance interface ......................................................................................................... 26
5.4.6 System log ........................................................................................................................................... 27
6.1 Communication interface ................................................................................................... 29
6.2 Operations of remote control on PC ................................................................................. 30
Chapter VII Maintenance ............................................................................................................ 44
AFV series power supply is a programmable power supply for grid simulation. By virtue of
advanced SPWM technology and direct digital frequency synthesis (DDS) waveform technology,
the power supply has stable output frequency and good continuity. AFV series power supply not
only can provide continuous, pure and stable sinusoidal voltage, but also can achieve local control
and remote control by the user’s PC for the power supply system through internal control and
communication modules. At the same time, the internal electronic circuit can quickly detect over
current, overload, overvoltage and output short circuit, automatically protect and cut off the output,
and send out an alarm. The integrative laminated busbar technology and modular configuration are
applied in the power supply inverter unit to improve reliability and stability. The touch screen
display and control are utilized for easier operation.
The main performance characteristics of AFV series variable frequency power supply are as
follows:
By virtue of advanced SPWM technology and direct digital frequency synthesis (DDS)
waveform technology are used, the power supply has stable output frequency and good
continuity;
The patented inner loop energy-saving test design is used to save the energy consumption;
High precision settings and output;
Comprehensive and stable protection, perfect self-diagnostic maintenance function and
higher system reliability;
The laminated busbar structure is used to effectively reduce the inductance of the inverter
circuit and improve the reliability of the inverter;
Intelligent fan speed regulation control is used with built-in dust filter to achieve efficient
heat dissipation and effective protection function under harsh environment;
Communication interface: Communication way RS485 (standard configuration) and
Ethernet (optional configuration);
Running event recording function is provided, and the number of records may be up to 255.
AFV variable frequency power supply User Manual
Chapter II Working Principle 2
Chapter II Working Principle
2.1 Functional block diagram of complete machine
All functional units of AFV series variable frequency power supply control system from input
to output according to the functional sequence are shown in Fig. 2-1.
Fig. 2-1 Functional block diagram of complete machine
AFV variable frequency power supply User Manual
Chapter II Working Principle 3
2.2 Description of functional block diagram
1) input: Connect from power supply endpoint to the input terminal disk of the equipment.
2) Input air switch: Control the commercial power input equipment.
3) Input filter: Input inductor and capacitor filter.
4) Rectifier filter: Convert the input alternating current into direct current.
5) Soft start: DC capacitor is charged slowly to reduce the impulse current.
6) Inverter circuit: Convert the direct current into PWM waveform.
7) Transformer filter: Boost the output voltage of IGBT and output the voltage after LC filter.
8) Output: The output voltage is transferred to the output terminal disk (or output copper bar)
through the contactor.
10) Voltage sampling: Input voltage sampling conditioning circuit.
11) SCR drive: Drive control circuit of soft start SCR.
12) IGBT drive: Amplify PWM signals to drive IGBT power components.
13) Voltage feedback: Steadily output voltage amplitude.
14) Voltage/current sampling circuit: Sampling conditioning circuit of output voltage and
current.
15) Power supply: Power supply of all PCB.
16) Main control circuit: The processing of all input and output signals.
17) Display: Touch screen display.
18) EPO: Emergency stop signal.
19) FUSE detection: Transmit the FUSE power-off signal to the control circuit for trip
protection.
20) Over-temperature detection: Transmit the over-temperature signal to the control circuit for
trip protection.
2.3 Constitution of main control circuit
The main control circuit is mainly divided into the three parts, namely protection sampling
module, main control module and display control module. The relationships between these three
parts are shown in Fig. 2-2.
Protection sampling
module
Main control module
Fig. 2-2 Block diagram of control parts
AFV variable frequency power supply User Manual
Display control
module
Chapter III Transportation and Installation
3.1 Transportation precautions
Chapter III Transportation and Installation 4
Fig. 3-1 Schematic diagram of transportation
Because the equipment is heavy, the lifting operations need to be slow during the
transportation of the forklift, so as to prevent damaging the equipment itself or the surroundings.
During the transportation that the equipment needs to be fixed firmly to prevent the equipment
from sliding or dumping due to vehicle bumps. Although the shockproof packaging was design in, it
is recommended that more cautious should be taken in consideration in case of driving on bumpy
roads.
3.2 Unpacking inspection
When open the wooden boxes which contain the equipment, pay extra attention on handling
it due to heavy weight consideration. Avoid dropping or dumping occurs.
Before turn on the equipment check the equipment condition if any damage was found. You
should inform service staff of our company to take proper treatment.
Check the accessories according to the delivery accessory list. If any accessories are missed,
please contact the customer service.
AFV variable frequency power supply User Manual
Chapter III Transportation and Installation 5
3.3 Installation environment requirements
When selecting the installation environment, the following matters should be followed:
1) Install the equipments in indoor and keep the environment air flow. Try to keep the
equipment air inlet/outlet free of dust;
2) The ground on which the equipment is installed should have sufficient strength and flatness,
and the equipment shall not shake after the installation is in place;
3) The equipment adopts incoming line and outgoing line. Therefore, it is recommended to
arrange these lines and cables connected to the external from the cable trenches, so as to
facilitate the installation and maintenance;
4) Where the equipment placed should give sufficient space to allow the heat which produced
by the equipment to radiate. (see Fig. 3-2) At the same time, do not cover the air inlet of
the front panel, for allowing heat to radiate;
5) Do not use the equipment in the environment with dust, volatile gases, too high saline matter
or corrosive substances, because this may affect the product life;
6) Do not place the equipment in the environment with too high temperature or humidity; and
away from water, flammable gases, corrosive or heat sources and avoid direct sunlight;
7) Use correct power distribution way to guarantee the safety of the equipment and user‘s
equipment.
Fig. 3-2 Schematic diagram of bottom of fixing device
AFV variable frequency power supply User Manual
Chapter III Transportation and Installation 6
3.4 Description of cable connection
The cable connection of the main circuit is as follows:
3.4.1 Single-phase input and single-phase output connection terminal
Input connection terminal is Copper bar as shown 3-3(b),while the machine capacity is greater
than 20k;
Fig. 3-3-(a)
Fig. 3-3-(b)
Fig. 3-3 Single phase input and single phase output connection terminal
3.4.2 Three-phase input and single-phase output connection terminal
Output connection terminal is Copper bar as shown 3-5(b),while the machine capacity is greater
than 15k; Input and Output connection terminal are Copper bar as shown 3-5(c),while the machine
capacity is greater than 60k;
Fig. 3-4-(a)
AFV variable frequency power supply User Manual
Fig. 3-4-(b)
Chapter III Transportation and Installation 7
Fig. 3-4-(c)
3.4.3 Three-phase input and three-phase output connection terminal
Input and Output connection terminal are Copper bar as shown 3-5(b),while the machine
capacity is greater than 60k;
Fig. 3-5-(a)
Fig. 3-5-(b)
Fig. 3-5 Schematic diagram of wiring terminal
AFV variable frequency power supply User Manual
Chapter III Transportation and Installation 8
Before installing the equipment, all the switches need to be disconnected. The circuit cables
should be connected properly according to the above diagram.
3.5 Cable wiring
1) Use the voltmeter to confirm whether there is no voltage output in the distribution lines;
2) Confirm whether all the switches of the variable frequency power supply are in the “OFF”
position;
3) The input and output cables can be selected according to the cables recommended in Tables
The reference cables recommended in the above-mentioned tables are multi-core flexible
copper cables, and the user can select different cables according to the input and output current
conditions by themselves. When the length of the input or output lines exceed 20 meters, it is
recommended that the wire diameter of the cable should be doubled.
4) Properly connect the input distribution lines to the corresponding wiring terminals at the input
terminal of the equipment successively, and connect the output load lines to the corresponding
wiring terminals at the output terminal of the equipment.
Fig. 4-1 Axonometric view of complete machine appearance
AFV variable frequency power supply User Manual
①
③ ②
⑤
Chapter V Operation 17
④
AFV variable frequency power supply User Manual
Chapter V Operation 18
Fig. 4-2 Description of complete equipment appearance
① Touch screen.
② Emergency stop button.
③ Input switch.
④ Input terminal;
⑤ Output terminal.
AFV variable frequency power supply User Manual
Chapter V Operation 19
Chapter V Operation
5.1 Initial power-up of system
The input and output wirings should be properly connected according to the input and output
connection way in Section 3.3. If the system is started, the main engine fan will start to operate, the
panel display screen is on and the main interface is entered, indicating that the start-up is normal
and the parameter setting can be conducted for the machine.
Note: If there is an external load, the load switch should be disconnected first, and the input
switch should be connected (it needs to confirm whether the electric power of the input terminal
row is normal before the input switch is connected).
Users can enter the application interface by clicking “Application”. Users can set the output
voltage and frequency value, press the [Operation] key after the setting is completed, and then click
“Meas.” to display the actual output each phase voltage, current, frequency, etc.
5.2 Menu description
Application
The application interface displays each phase voltage, current and frequency of output terminal
of the AFV(equipment).
System
In the application interface, time setting and system maintenance can be setting by
requirement.
Event
Record the historical work information of the equipment.
AFV variable frequency power supply User Manual
Chapter V Operation 20
5.3 Parameter setting
Parameters set up correctly is basic requirement for running the AFV(equipment) smoothly.
Detailed user modes are described as follow.
5.3.1 Start-up
When the AFV(equipment) power on, the screen will show company LOGO as shown in Fig.
5-1.
Fig. 5-1 Start-up interface
The initialization interface is shown in Fig. 5-2.
Fig. 5-2 Initialization interface
AFV variable frequency power supply User Manual
Chapter V Operation 21
5.3.2 User mode
Enter the main menu of the user mode. The interface display is shown in Fig. 5-3.
Fig. 5-3 Main menu of user mode
【APP】--Application: Enter the operation setting interface;
【SYSTEM】: Enter the time setting and system maintenance interface;
【EVENT】: Enter the equipment work record information table interface.
AFV variable frequency power supply User Manual
Chapter V Operation 22
5.4 Application interface
In the application interface, users can conduct the operations of the general mode, Step mode,
Gradual mode and Measurement mode of the equipment.
Note: All the product information in the operation interface of the equipment should comply
with the model specifications of the actual equipment.
5.4.1 General mode
(a) Three-phase output setting interface
(b) Single-phase output setting interface
Fig. 5-4 Setting interface of general mode
【Limit Curr.】:Setting different current protection value.
【Individually Adjust】:Individual Adjust Volt. When this option is chosen, each phase can
be set up independently.
【Phase Setting】:When this option is chosen, the phase angle can be set up.
The following three ways can be used for setting voltage at all phases:
a) Directly input the voltage value in. Click the box to pop up the keyboard, and
then input the voltage value;
b) In the box of touch left and right for adjustment;
c) Click & to conduct the setting. The variation unit is 0.1.
Note:If the【Individual Adjust Volt.】 is not picked,setting up a value on a specific single
phase, the value on the same field for the other two phases will be changed to the same
value as the one you just entered simultaneously.
【Freq】:Frequency: The setting way is same as that of voltage;
【LOW】: The equipment starts to output the low voltage after clicking it;
【HIGH】: The equipment starts to output the high voltage after clicking it;
【RUN】: The equipment starts the output according to the set value after clicking it;
【STOP】: The equipment stops the output after clicking it;
【RESET】: The equipment restores the initial state after clicking it;
【】: AC indicator light displays the operational state of the AC output of the equipment:
Red represents that the mode of the equipment is in the stop state, while green represents
that the mode of the equipment is running.
5.4.2 Step mode
(a) Step mode setting interface
AFV variable frequency power supply User Manual
Chapter V Operation 24
(b) Step mode effect interface
【SETTING】: Download the set parameters;
【RUN】: The equipment starts to run the step mode after clicking it;
【RESET】: The equipment restores the initial state after clicking it;
【STOP】: The equipment stops running the step mode after clicking it;
&: Switch over step setting interface and step effect interface.
5.4.3 Gradual mode
(a) Gradual mode setting interface
AFV variable frequency power supply User Manual
(b) Gradual mode effect interface
【SETTING】: Download the set parameters;
Chapter V Operation 25
【RUN】: The equipment starts to run the gradual mode after clicking it;
【RESET】: The equipment restores the initial state after clicking it;
【STOP】: The equipment stops running the gradual mode after clicking it;
&: Switch over gradual change setting interface and gradual change effect interface.
5.4.4 Measurement mode
(a) Three-phase output setting interface
AFV variable frequency power supply User Manual
(b) Single -phase output setting interface
Fig. 5-7 Real-time acquisition interface
【MEAS.】--Measurement: Real-time acquisition;
Chapter V Operation 26
【STOP】: The equipment stops the output after clicking it;
【RESET】: The equipment restores the initial state after clicking it;
Fig. 5-8 Fault alarm interface
【RESET】: Fault reset;
【OK】: Click it to return to the real-time acquisition interface.
5.4.5 System maintemance interface
AFV variable frequency power supply User Manual
【Date】: Setting the date;
Chapter V Operation 27
Fig. 5-9 System maintemance interface
【Time】: Setting the time
【System Setting】: The system configuration is only for the users to view, and it cannot be
modified. If it needs to modify the system configuration, please contact the manufacturer
and customer service personnel;
【Addr】:Setting the communication address, default value is 2;
【COMM Type】: Select the communication interface (or protocol), default is RS485;
【Phase Setting】:Option function ,Click it to Enter the Phase setting interface.
Fig. 5-10 Phase setting interface
5.4.6 System log
System log interface is shown in Fig. 5-11.
AFV variable frequency power supply User Manual
Chapter V Operation 28
Fig. 5-11 System log setting interface
【Previous】/【Next】: Browse the historical event contents;
【Clear】: Empty the system log table;
【Back】: Return to the previous menu.
AFV variable frequency power supply User Manual
Chapter VI Operation 29
Chapter VI Remote Control
6.1 Communication interface
RS-485 and RS-232 are standard communication interfaces for this series of machine. RS-232
supports SCPI command and RS-485 supports MODBUS RTU command. The RS-232 and
RS-485 belong to the same interface with different pins and need to be configured in factory.
LAN, USB, GPIB options apply different converters and connect to the RS-232/485 port.
6.1.1 Interface of RS-232/485
Open the front cover, RS-232/RS-485 interface is located in the back of touch screen shown as
below figure:
a) Back of the touch screen computer
RS-485 interface is female connector,
and has nine pins
Pin
1 Rx-(B) RS 485 B
5 GND Signal Gnd
6 Rx+(A) RS 485 A
b) Pin definition of this RS-485interface
RS-232 interface is female connector,
and has nine pins
Pin
2 RXD TXD
3 TXD RXD
5 GND Signal Gnd
c) Pin definition of this RS-232 interface
Fig. 6-1 Pictures of RS485 connection
6.1.2 Indication of remote control on touch screen
Signal PC
Signal PC
While the communication interface of this machine is successfully linked with other
computing equipment, there will be an indication text (“under remote control …”) shown on the
AFV variable frequency power supply User Manual
screen, as below figure:
Chapter VI Operation 30
(a) Three-phase output setting interface
(b) Single-phase output setting interface
Fig. 6-2 “Under remote control”… shown on screen
6.2 Operations of remote control on PC
6.2.1 Software installation
Open the software CD package, install the software by executing the setup.exe in the CD, as
shown in the below picture.
AFV variable frequency power supply User Manual
Fig. 6-3 Software installatin kit on the CD
Chapter VI Operation 31
Operating system supported: Windows XP、WIN7、WIN8.
Fig. 6-4 Procedures of the installation: 1st step.
AFV variable frequency power supply User Manual
Fig. 6-5 Procedures of the installation: 2nd step.
Chapter VI Operation 32
Choose the installation folder, recommend installing on D:\ disk (do not install on system disk).
Fig. 6-6 Procedures of the installation: 3rd step.
AFV variable frequency power supply User Manual
Chapter VI Operation 33
Fig. 6-7 Shortcut on the PC desktop after successful installation
6.2.2 Operations on PC
Double click the shortcut (as shown in fig. 6-7) on the desktop, then enter the communication
setting UI (as shown in fig. 6-8). Before communication interface are successfully linked, the
operation button 【Read Dev. Info.】is grayed (and can not operate).
图 6-8 Communication UI
Dev Addr:Address of this machine while in communication,for this series (AFV) of
machines, default value is 2;
Comm mode: Select the communication interface (or protocol), default is RS485;
Comm :Serial number of the com port to be selected;
【Link】:Click on this button after setting up all the required parameters for that specific
communication mode, physical link is created. Status of this action will be shown on the
blank area below this button.
Other communication parameter is fixed: 9600bps,databit:8, stopbit:1,check:None;
After a successful connection, button 【Read Dev. Info.】lift ashing, click【Read Dev. Info.】
(communication right) enter such as 6-9 shown in the device information display interface:
AFV variable frequency power supply User Manual
Chapter VI Operation 34
6-9 System Config UI
Users can view the system configuration information read from the power supply
equipment is consistent with the parameters of the actual product, if it does not meet, please
contact customer service staff to resolve.
After system configuration parameters confirm, click 【Enter】 button to enter the main
interface of the software function, as shown in figure 6-10.
6.2.3 Main interface
AFV variable frequency power supply User Manual
Chapter VI Operation 35
(a) Three-phase output setting interface
(b) Single-phase output setting interface
Fig. 6-10 Main interface of upper computer
AFV variable frequency power supply User Manual
Chapter VI Operation 36
In the above menu:
【New】:Create a new file for system data storage;
【Open】:Open an existing system data file;
(1) 【Save】:Store all the data that users have created into the current system data file;In the
menu of “Basic App”, click on【Step】,and get into all the options and actions in “step”
mode.
(a) Menu of “step change” – Parameters settings
AFV variable frequency power supply User Manual
Chapter VI Operation 37
(b) Menu of “step” – Results preview
Fig. 6-11 Menu of “step” mode in remote control
【Cycle parameter】:The machine will start the output from the first procedure set in “Start
No.” to the last procedure set in “End No.”, and execute the whole procedures continuously
for the number of iteration of the parameter set in this field. The maximum number of
procedures that can be stored is 24. The maximum number of iteration is 255.
Click on【Preview】can preview the procedures (once executed) in time domain;
【Setting】:Save all the parameters in the touch screen into the control unit . User has to
execute this action before running the whole “Step” procedures;
All the data the users enter in this menu will be saved, once any of the action buttons of
【Preview】, 【Setting】 or 【Run】is clicked.
【】 indicator :Red light indicates that the machine is in idle state (output stopped),
while green light indicates the machine is in normal working state (output activated).
Note:If none of the above 3 action buttons has been clicked, all the data the user has entered
in this session will be lost once this menu is exited.
【Run】Once clicked, the machine will start the output immediately as above procedures
setup;
【Stop】 Once clicked,the machine will stop the output immediately;
【Reset】Once clicked, the machine will release itself from the “alarm” state.
AFV variable frequency power supply User Manual
Chapter VI Operation 38
(2) In the menu of “Basic App”, click on 【Gradual】will bring you to the menu of “Gradual” mode.
(a) Menu of “Gradual” – Parameters settings
(b) Menu of “Gradual” – Results preview
Fig. 6-12 Menu of “Gradual” mode under remote control
【Cycle parameter】:The machine will start the output from the first procedure set in “Start
AFV variable frequency power supply User Manual
Chapter VI Operation 39
No.” to the last procedure set in “End No.”, and execute the whole procedures continuously
for the number of iteration of the parameter set in this field. The maximum number of
procedures that can be stored is 12. The maximum number of iteration is 255.
Click on【Preview】can preview the procedures (once executed) in time domain.
【Setting】:Save all the parameters in the touch screen into the control unit inside the
machine, the user have to execute this action before running the whole “Gradual”
procedures.
All the data the users enter in this menu will be saved, once any of the action buttons of
【Preview】, 【Setting】 or 【Run】is clicked.
【】 indicator :Red light indicates that the machine is in idle state (output stopped),
while green light indicates the machine is in normal working state (output activated).
Note:If none of the above 3 action buttons has been clicked, all the data the user has entered
in this session will be lost once this menu is exited.
【Run】Once this button is clicked, the machine will start the output immediately as above
procedures setup;
【Stop】 Once clicked,the machine will stop the output immediately;
【Reset】Once clicked, the machine will release itself from the “alarm” state
(3) Click on【Measure】will enter the menu of “Measure”.
(a) Three-phase output setting interface
AFV variable frequency power supply User Manual
(b) Single-phase setting interface
Chapter VI Operation 40
Fig. 6-13 General Mode
(a) Three-phase output setting interface
AFV variable frequency power supply User Manual
(b) Single-phase setting interface
Fig. 6-13 Menu of “Measure” under remote control
Chapter VI Operation 41
“Interval” : The time interval fixed the default value:1000ms.
“Record Logs”: Save all the data measured in this mode into a log file.The file
path:C://ACPower.
“Measure” collection and “Stop” collection can be clicked and executed any time.
Input measure data:R/S/T phase data is measure on anytime.
Output measure data:U/V/W phase data is measure when the device running.
Note: these items can be selected only under the collection is ongoing.
(4) Click on the sub-menu of【Language Setting】, there are 3 kinds of languages can be chosen.
Click on the language you want, and all the user-interface in this software will be changed to
that language.
AFV variable frequency power supply User Manual
Chapter VI Operation 42
(a) Three-phase output setting interface
(b) Single-phase setting interface
Fig. 6-14 Language selection under rermote control
(5) Click on 【 Apply Setting 】 will enter the menu of “Phase Angle and Max Curr.
AFV variable frequency power supply User Manual
Setting”.(Optional function)
Chapter VI Operation 43
(a) Phase Angle and Max Current optioning interface
(b) Phase Angle setting interface
(c) Max Current setting interface
Fig. 6-15 Phase Angle and Max Current setting interface
AFV variable frequency power supply User Manual
Chapter VII Maintenance 44
Chapter VII Maintenance
Extreme temperature, high humidity, heavy dust, chemicals pollution and physical vibration
all could impose negative impacts on the life and reliability of this machine. Nevertheless, the
nature aging of all the electrical and mechanical components would further cause it to be more
vulnerable to all kinds of faults. Therefore, routine and periodic maintenance are necessary and key
to the reliability of this machine in the long run.
Only authorized and trained technical professionals are allowed to carry out the
maintenance on this machine.
7.1 Routine maintenance
First, the daily operating environment must comply with the requirements stated in this user
manual. Routine inspection on the environment and the machine should be checked on a regular
basis. All the environment data, the operating status and the parameters set in the machine should
be recorded as well. It is best to have a detailed and accurate “machine usage log file” for all time
reference and maintenance.
Abnormal phenomenon on the machine can be detected by the routine inspection and
maintenance. Once observed, the users should try to identify the root cause first and remove the
problem immediately. Call our customer service if you are not able to identify the cause, or not able
to remove the problem. The earlier the problem can be removed, the longer the life of the machine.
Checking items in the routine maintenance are listed in Table 7-1.
Table 7-1 List of checking items on routine maintenance
Inspection details
Object
to
check
Checking items
When
to
Methods to check
Criteria
check
(1). Temperature and
humidity
Environ
-ment
(2). Dust, moisture and
water leakage (drop on
the machine).
(3). Abnormal Chemical
vapor
AFV variable frequency power supply User Manual
Anytime
(1).Thermometer,
Hygrometer
(2). Visual inspection
(3). Visual inspection
and smell
(1). Ambient temperature must < 45˚C,
or maximum load need to be de-rated.
Humidity should be comply with the
spec requirements.
(2). Little dust, no condensing, no
water drop on the machine.
(3). No abnormal smell, no abnormal
color in the air.
Depending on the usage of this machine and the environment where it works,a periodic
maintenance can be carried out once every 3~6 months.
Chapter VII Maintenance 45
⑴No shock, no vibration。
⑵Fan operating: check to see if speed
and air flow volume OK or not.
Measure the temperature on the
surface of the enclosure; they should
not have more than 30˚C temperature
rise.
⑶ No abnormal acoustic noise.。
⑴within the spec limit
⑵within the spec limit
⑶within the spec limit
⑷Temperature rise < 45˚C
Maintenance task:
Screen filter for the air inlet should be detached and washed clean.
Note:Open the front door of the enclosure to detach and re-install the screen filter, there is a
cover in front of the screen filter, it needs to be removed before the filter can be accessed.
AFV variable frequency power supply User Manual
Chapter VIII Troubleshooting and Solutions 46
Chapter VIII Troubleshooting and Solutions
Before seeking services, users can first do self-inspection and record fault phenomena in
details according to tips in this section. When you need to seek services, please contact the dealer.
Table 8-1 Alarm contents and solutions
Fault
code
Err-01 U-phase IGBT1 overcurrent fault
Err-02 U-phase IGBT2 overcurrent fault
Err-03 U-phase IGBT3 overcurrent fault
Err-04 U-phase IGBT4 overcurrent fault
Err-05 V-phase IGBT1 overcurrent fault
Err-06 V-phase IGBT2 overcurrent fault
Err-07 V-phase IGBT3 overcurrent fault
Err-08 V-phase IGBT4 overcurrent fault
Err-09 W-phase IGBT1 overcurrent fault
Err-10 W-phase IGBT2 overcurrent fault
Err-11 W-phase IGBT3 overcurrent fault
Err-12 W-phase IGBT4 overcurrent fault
Err-13
Radiator over-temperature The fan works abnormally Check the fan
Fault type Possible causes of faults Solutions
U-phase IGBT is damaged Check and replace IGBT
U-phase IGBT is damaged Check and replace IGBT
U-phase IGBT is damaged Check and replace IGBT
U-phase IGBT is damaged Check and replace IGBT
V-phase IGBT is damaged Check and replace IGBT
V-phase IGBT is damaged Check and replace IGBT
V-phase IGBT is damaged Check and replace IGBT
V-phase IGBT is damaged Check and replace IGBT
W-phase IGBT is damaged Check and replace IGBT
W-phase IGBT is damaged Check and replace IGBT
W-phase IGBT is damaged Check and replace IGBT
W-phase IGBT is damaged Check and replace IGBT
Err-14
Err-15
Err-16
Err-19
Err-20
Err-21
Err-22
Err-23
Err-24
Err-25
Err-26
Err-27
Err-28
Err-29
Transformer over-temperature The fan works abnormally Check the fan
Emergency stop button
The emergency stop button
is presses
Fuse 1 is broken The fuse blows out Check and replace the fuse
IGBT over-temperature 1 The fan works abnormally Check the fan
IGBT over-temperature 2 The fan works abnormally Check the fan
Input undervoltage fault The input voltage is too low
Input overvoltage fault The output voltage is too high Check the input voltage
DC voltage is too low The input voltage is too low Check the input voltage
DC voltage is too high The output voltage is too high
U overload U-phase overload Check the load
V overload V-phase overload Check the load
W overload W-phase overload Check the load
Output undervoltage fault The output voltage is too low Check the output voltage
Output overvoltage fault The output voltage is too high Check the output voltage
Check the emergency stop
button
Check the input voltage
Check the input voltage
AFV variable frequency power supply User Manual
Chapter Ⅸ Customer Service 47
Chapter Ⅸ Customer Service
Preen provides all kinds of technical service to its customers. Please first contact the sales
representative from whom you acquire this machine for any questions or problems. If you not able
to reach that sales representative, then you are welcome to contact the nearest branch office or our
Suzhou central office for solid support. Our contact information are listed as follows:
Telephone:(+1) 949-988-7799
Support on the web:www.PreenPower.com
Customers may browse our website to seek technical information or on-line support.
Our website:
http://www.PreenPower.com
Our Email for customers:
E-mail:support@acpower.net
Please refer to the provisions in the warranty contract for details of the maintenance tasks. We
do provide our customers with various kinds of packages for paid service in which there are
different levels of customization. These paid services includes “fast response on issues
encountered”, “preventive maintenance” and “continuation of warranty after original warranty
expires”. Contact the sales representative or the branch office for more detail
AFV variable frequency power supply User Manual
Appendix Guarantee Card 48
Appendix Guarantee Card
Quality
Service
Innovation
Warranty
For customer, _______________________________________________
Model: __________________________________ Serial Number: _____
Should this machine malfunction or fail due to material or manufacturing flaws within one year, AC Power
Corp. (APC) will take full responsibility for the repairs. This warranty only holds if the machine has been operating
for normal use and in the normal environment specified in the manual. APC reserves the right to charge the
customer for the repairs if the defects are due to any cause other than material or manufacturing flaws, and/or if the
defects are due to any cause resulting from operating in a severe environment (factors beyond the allowable limits).
The warranty begins on the date when this machine is installed and our sales representative signs this document;
it is only valid when the machine has been installed correctly and while operated properly. No modifications on the
structure or circuitry and no replacement of any components by unauthorized personnel are allowed under this
warranty.
In case of machine malfunction or failure, please call our customer service for help first. Under some situations
and directed by our company staffs, you may need to uninstall it, pack and wrap it up securely, and then send it back
to us with a description of the problems encountered. We shall resolve your problems as soon as possible.
Please keep this warranty paper all the time even after it expires. We will only take a minimum charge for
the repairs after the warranty’s expiration if you still hold this paper.
Thank you for choosing AC Power Corp.
AFV variable frequency power supply User Manual