Precor, AMT, and EFX are registered trademarks and Preva is
a trademark of Precor Incorporated. Other names in this
document may be the trademarks or registered trademarks of
their respective owners.
Intellectual Property Notice
All rights, title, and interests in and to the software of the
Preva Business Suite, the accompanying printed materials,
any copies of such software, and all data collected via the
Preva Business Suite, are exclusively owned by Precor or its
suppliers, as the case may be.
Precor is widely recognized for its innovative, award-winning
designs of exercise equipment. Precor aggressively seeks U.S.
and foreign patents for both the mechanical construction and
the visual aspects of its product design. Any party
contemplating the use of Precor product designs is hereby
forewarned that Precor considers the unauthorized
appropriation of its proprietary rights to be a very serious
matter. Precor will vigorously pursue all unauthorized
appropriation of its proprietary rights.
Read the following precautions thoroughly before you begin
assembly, and save them afterward for future reference.
Safety Precautions
Always follow basic safety precautions when using this
equipment to reduce the chance of injury, fire, or damage.
Other sections in this manual provide more details of safety
features. Be sure to read these sections and observe all safety
notices. These precautions include the following:
Read all instructions in this guide before installing and
using the equipment and follow any labels on the
equipment.
Make sure all users see a physician for a complete
physical examination before they begin any fitness
program.
Il est conseillé de subir un examen médical complet avant
d’entreprendre tout programme d’exercise. Si vous avez des
étourdissements ou des faiblesses, arrêtez les exercices
immédiatement.
Do not allow children, or people unfamiliar with the
operation of this equipment, on or near it. Do not leave
children unsupervised around the equipment.
Make sure all users wear proper exercise clothing and
shoes for their workouts and avoid loose or dangling
clothing. Users should not wear shoes with heels or
leather soles, and they should check the soles of their
shoes to remove any dirt and embedded stones. They
should also tie long hair back.
Never leave the equipment unattended when it is plugged
in. Unplug the equipment from its power source when it is
not in use, before cleaning it, and before providing
authorized service.
Note: The optional power adapter is considered a power
source for self-powered equipment.
4 Assembling and Maintaining the 835 Climber
Use the power adapter provided with the equipment. Plug
the power adapter into an appropriate, grounded power
outlet as marked on the equipment.
Care should be taken when mounting or dismounting the
equipment.
Read, understand, and test the emergency stop
procedures before use.
Keep the power cord or optional power adapter and plug
away from heated surfaces.
Route power cables so that they are not walked on,
pinched, or damaged by items placed upon or against
them, including the equipment itself.
Ensure the equipment has adequate ventilation. Do not
place anything on top of or over the equipment. Do not
use on a cushioned surface that could block the
ventilation opening.
Assemble and operate the equipment on a solid, level
surface.
Proper Location for Equipment
For all equipment other than treadmills: Locate at
least 40 inches (1 meter) away from walls or
furniture on either side of the equipment, and 40
inches (1 meter) away from objects behind the
equipment.
For treadmills: Locate at least 40 inches (1 meter)
away from walls or furniture on either side of the
treadmill, and at least 80 inches (2 meters) away
from objects behind the treadmill.
Keep equipment away from water and moisture. Avoid
dropping anything on or spilling anything inside the
equipment to prevent electric shock or damage to the
electronics.
Do not operate electrically powered equipment in damp
or wet locations.
Never operate this equipment if it has a damaged cord or
plug, if it is not working properly, or if it has been dropped,
damaged, or exposed to water. Call for service
immediately if any of these conditions exist.
Maintain the equipment to keep it in good working
condition, as described in the Maintenance section of the
assembly and maintenance guide. Inspect the equipment
for incorrect, worn, or loose components, and then
correct, replace or tighten prior to use.
Important Safety Instructions 5
If you plan to move the equipment, obtain help and use
proper lifting techniques. refer to the "Moving the
Equipment" section of the assembly and maintenance
guide.
Use the equipment only for its intended purpose as
described in this manual. Do not use accessory
attachments that are not recommended by Precor. Such
attachments may cause injuries.
Do not operate the equipment where aerosol (spray)
products are being used or where oxygen is being
administered.
Do not use outdoors.
Do not attempt to service the equipment yourself, except
to follow the maintenance instructions in this manual.
Never drop or insert objects into any opening. Keep hands
away from moving parts.
Do not set anything on the stationary handrails,
handlebars, control console, or covers. Place liquids,
magazines, and books in the appropriate receptacles.
Do not lean on or pull on the console at any time.
CAUTION : DO NOT remove the cover, or you may risk injury due
to electric shock. Read the assembly and maintenance guide
before operating. There are no user-serviceable parts inside.
Contact Customer Support if the equipment needs servicing. For
use with single phase AC supply only.
Educating Users
Take time to educate users about the Important Safety
Instructions found in both the User Reference Manual and
Product Owner’s Manual. Explain to your club or facility
patrons that they should observe the following precautions:
Hold onto a stationary handrail or handlebar while
assuming the starting position on the equipment.
Face the console at all times.
Hold on to a stationary handrail or handlebar with one
hand whenever you operate the console keys with the
other hand.
6 Assembling and Maintaining the 835 Climber
Hazardous Materials and Proper Disposal
The batteries within self-powered equipment contain
materials that are considered hazardous to the environment.
Federal law requires proper disposal of these batteries.
If you plan to dispose of your equipment, contact Precor
Commercial Products Customer Support for information
regarding battery removal. Refer to Obtaining Service.
Product Recycling and Disposal
This equipment must be recycled or discarded according to
applicable local and national regulations.
Product labels, in accordance with European Directive
2002/96/EC concerning waste electrical and electronic
equipment (WEEE), determine the framework for the return
and recycling of used equipment as applicable throughout the
European Union. The WEEE label indicates that the product is
not to be thrown away, but rather reclaimed upon end of life
per this Directive.
In accordance with the European WEEE Directive, electrical
and electronic equipment (EEE) is to be collected separately
and to be reused, recycled, or recovered at end of life. Users
of EEE with the WEEE label per Annex IV of the WEEE
Directive must not dispose of end of life EEE as unsorted
municipal waste, but use the collection framework available
to customers for the return, recycling, and recovery of WEEE.
Customer participation is important to minimize any potential
effects of EEE on the environment and human health due to
the potential presence of hazardous substances in EEE. For
proper collection and treatment, refer to Obtaining Service.
Regulatory Notices for the RFID Module
When equipped with a control console as described in this
document, this equipment may include a radio-frequency
identification (RFID) module. The RFID module has been
certified to operate at temperatures between -20ºC and 85°C
(-4°F and 185°F).
Important Safety Instructions 7
Radio Frequency Interference (RFI)
The RFID module conforms to the following national
standards defining acceptable limits for radio frequency
interference (RFI).
Federal Communications Commission, Part 15
This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a commercial
installation. The equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the owner’s manual instructions, can cause
harmful interference to radio communications.
Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.
WARNING
Per FCC rules, changes or modifications not
expressly approved by the manufacturer could
void the user’s authority to operate the
equipment.
Industry Canada
This device complies with RSS-210:2007 of the Spectrum
Management & Telecommunications Radio Standards
Specification. Operation is subject to the following two
conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference
received, including interference that may cause undesired
operation.
This Class A digital apparatus complies with Canadian
ICES-003.
Cet appareil numérique de la classe A est conforme à la norme
NMB-003 du Canada.
ATTENTION: Haute Tension
Débranchez avant de réparer
8 Assembling and Maintaining the 835 Climber
European Applications
CE compliance is claimed to the following directives:
Directive compliance has been verified to the following
standards:
EN 55022
EN 300 330-1 V1.5.1
EN 300 330-2 V1.3.1
EN 301 489-3 V1.4.1
EN 301 489-1 V1.8.1
EN 60950-1
Regulatory Notices for Cardiovascular
Exercise Equipment
The regulatory information in this section applies to the
exercise equipment and its control console.
Safety Approvals for Cardiovascular Equipment
Precor equipment has been tested and found to comply with
the following applicable safety standards.
Cardiovascular Type Equipment:
CAN/CSA, IEC, EN 60335-1 (Household and similar
electrical appliances - Safety)
EN 957 (Stationary training equipment, class S/B
compliant equipment)
Important Safety Instructions 9
Radio Frequency Interference (RFI)
This Precor exercise equipment conforms to the following
national standards defining acceptable limits for radio
frequency interference (RFI).
Federal Communications Commission, Part 15
This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a commercial
installation. The equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the owner’s manual instructions, may cause
harmful interference to radio communications.
WARNING
Per FCC rules, changes or modifications not
expressly approved by Precor could void the
user’s authority to operate the equipment.
Industry Canada
This Class A digital apparatus complies with Canadian
ICES-003.
Cet appareil numérique de la classe A est conforme à la norme
NMB-003 du Canada.
ATTENTION: Haute Tension
Débranchez avant de réparer
European Applications
CE compliance is claimed to the following directives:
Directive compliance has been verified to the following
standards:
EN 55022
EN 55024
EN 60335-1
EN 60065 (P80 and PVS)
10 Assembling and Maintaining the 835 Climber
Electrical Recommendations: All Equipment
Excluding Treadmills
Note: This is a recommendation only. NEC (National Electric
Code) guidelines or local region electric codes must be
followed.
For equipment fitted with a P80 console or Personal Viewing
System (PVS) screen a separate power connection is
required. For a 20 amp branch circuit up to 10 screens can be
connected. If the branch circuit has any other devices plugged
into the circuit the number of screens must be reduced by the
wattage of the other devices.
Note: The typical splitter power cords that have IEC-320 C13
and C14 plugs have a recommended maximum capacity of
five screens.
Figure 1: IEC-320 C13 and C14 plugs
Obtaining Service
Do not attempt to service the equipment except for
maintenance tasks. If any items are missing, contact your
dealer. For more information regarding customer support
numbers or a list of Precor authorized service centers, visit
the Precor web site at http://www.precor.com.
Obtaining Updated Documentation
Current documentation for Experience Series consoles and
Preva Networked Fitness software is available at
http://www.precor.com/productmanuals. You may want to
check in for updated information from time to time as the
universe of Preva features expands.
Table of Contents
Important Safety Instructions ................................................... 3
Safety Precaution s .................................................................................3