PreView Side Defender II
SDR8503 & SDL8503
SDR8504 & SDL8504
System Operating Manual
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Warning: Changes or modications to this unit not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interferenc e to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try and correct the interference.
INDUSTRY CANADA STATEMENT
Per RSS-Gen, Section 8.4 This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Par RSS - Gen, Section 8.4 Cet appareil est conforme à Industrie Canada exempts de licence standards RSS. Le
fonctionnement est soumis aux deux conditions suivantes : (1 ) ce dispositif ne peut pas provoquer d’interférences et ( 2)
cet appareil doit accepter toute interférence , y compris les interférences qui peuvent causer un mauvais fonctionnement
de l’appareil.
APS-SUPPLY.COM
REGULATORY COMPLIANCE
The PreView® Side Defender® is compliant with the following countries/regions and their regulations as of the published
date of this manual. The sensor may be compliant in other countries/regions. Please check your local regulations or
contact PRECO Electronics® for support.
• United States - FCC- Part 15.249
• FCC ID: OXZJCKP2016
• Canada - RSS-210 Radio Standards Specication
• IC ID:
• European Union - ETSI EN300 440-1 Electromagnetic Compatibility and Radio Spectrum Matters (ERM)
• Australia/New Zealand - AS/NZ 4268 Radio Equipment and Services – Short Range Devices
Patent pending
This document may be amended, corrected, and enhanced in keeping with the sensor development progress. The most
recent version can be found at www.preco.com
TRADEMARKS
The names of actual companies and products mentioned herein may be the trademarks of their respective owners. Any
rights not expressly granted herein are reserved.
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
Warranty Information ........................................................... 15
More PRECO Electronics® Safety Products ........................ 16
APS-SUPPLY.COM
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
Product Description
The PreView® Side Defender® is an FMCW radar object detection system designed to alert operators of medium and
heavy-duty over-the-road vehicles of obstacles in their side blind zones. The Side Defender® has intelligent modes of
operation that help minimize false alerts due to xed objects such as guardrails, while still providing reliable side object
detection.
APS-SUPPLY.COM
Figure 1. PreView® Side Defender™ Radar Sensor
The Side Defender is congured in four different ways:
PositionSlow Speed OFFSlow Speed ON
Right SideSDR8503SDR8504
Left SideSDL8503SDL8504
Each conguration comes with an in-cab display and a body harness cable.
Sensor Description
The PreView® Side Defender® is a small, rugged short range radar sensor designed and made by PRECO Electronics®
in the USA for use in heavy-duty applications such as trucks/busses, waste vehicles and other applications requiring
a robust, high-performance side blind-zone radar. The sensor transmits and receives low power narrow band 24 GHz
radar signals. It then processes the returned signals to determine if an object has reected any energy back to the
sensor. If an object presents a collision threat, it is reported to the operator display. The sensor is designed to process
and report detections within 300 ms allowing the operator to quickly respond to any object within the detection zone.
The frequency band used is legal throughout most of the world, but check with PRECO Electronics® or your
country’s regulations before purchasing.
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
The PreView® sensor has a continuous Built-In-Self-Test (BIST) that noties the operator via the in-cab display of sensor
failure within a fraction of a second. This test functions by monitoring the transmit and receive performance as well as
other internal operations. The BIST reporting functionality is a critical feature for fail-safe operation.
Using frequency modulated transmit waveform (FMCW) technology, the Side Defender® radar measures radial range,
speed, angle, reectivity, and other parameters of multiple stationary and moving targets simultaneously. This radar
sensor has a wide horizontal eld of view up to +/-75°, optimized for side object detection in large trucks and busses.
When traveling above 10 mph (16 kph) the horizontal eld-of-view for all models is approximately 40 feet along the
side and 10 feet wide. When traveling at slower speeds, models with Slow Speed ON, have a horizontal eld of view of
approximately 12 feet along the sides and 10 feet wide. See Figure 2.
Target: Distance, Angle, Speed, Reectivity
APS-SUPPLY.COM
Figure 2. Horizontal Detection Zone
PreView® Side Defender® can detect people, bicycles, motorcycles and other cars/trucks within the detection zone,
providing a visual alert on the in-cab LED display, as well as an audible alert if the turn signal is active. Figure 3 shows
the in-cab LED display.
The Side Defender® radar performance is not affected by other PreView® Radar or similar sensors operating in close
proximity with each other.
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
PreView® In-cab LED Display Description
The in-cab display provides the vehicle operator with visual and audible alerts when an object is detected.
The audible notication is only used when the associated turn signal is active and will only sound upon the
rst detection of a specic object. The audible alert will not sound again until the turn signal is cycled or a new
object enters the detection zone.
APS-SUPPLY.COM
Display Buzzer
Figure 3. In-cab LED Display Unit
Table 1. Operator Display Description
ItemDescription
Status LED*
Detection LED*Illuminates to alert operator to the presence of an object
Light Sensor*
Display Buzzer*Sounds an audible tone to alert operator of obstacles
Illuminates green after power is applied to the system. Turns off
anytime the detection LED is illuminated.
Measures ambient light conditions allowing for Status and Detection
LEDs’ brightness to automatically adjust
Light Sensor (Dimming)
Detection LED
Status LED
*Locations of LEDs and buzzer are different for left side kit.
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
www.aps-supply.com
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
Sensor Interfaces and Conguration
DO NOT use your vehicle’s CAN-Bus to communicate between
the PreView® Side Defender® Radar and the in-cab display
CAN-Bus Speed Message
The Side Defender® supports certain J1939 vehicle speed messages provided by the vehicle’s CAN-Bus. Contact
PRECO Electronics® for more information about how this can be used.
Turn Signal Input
The Side Defender® requires a turn signal input for proper in-cab display operation. When the turn signal is active, the
display’s audible alert will sound once when an object is detected. Refer to the Wiring Connections diagram (Figure 4)
for more information.
Auxiliary Output
The Side Defender® radar supports an auxiliary output signal that can be used to provide additional operator alerts.
This output is an Active Low (switch to ground). One example use of this output is to drive an LED indicator in a side
mirror when there is an object in the side blind zone. Contact PRECO Electronics® for more information.
APS-SUPPLY.COM
System Connections
Locate the vehicle’s ignition power and connect to the red wire on the body harness. If it is necessary to extend the
power wire on the supplied harness, use 20 AWG wire as a minimum. Locate the vehicle’s turn signal wire associated
with the turn signal on the sensor side and connect to the blue wire on the body harness. (Be sure that the turn signal
wire selected activates ONLY when the turn signal is active. On some trucks the daytime running lights and/or
air brakes will activate the wires connected to the turn signal lamp). Connect the black wire of the body harness
to vehicle ground.
Figure 4. Wiring Connections
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
Object Detection Capability
The PreView® Side Defender® radar system is a blind spot collision warning system designed to
supplement other safety practices and/or devices. The vehicle operator is always the rst line of
defense when safely operating a vehicle.
The PreView Side Defender® can detect most objects within the detection zone. However, there are some instances
where objects can go undetected. Obstacle size, shape, orientation, relative location, and composition are all factors
determining if, when, and where an object is detected. The Side Defender® radar operates by transmitting low power
electromagnetic energy. Any energy that strikes an object reects a certain amount of this energy back to the Side
Defender® radar. If the returned energy is of sufcient magnitude, it is used to indicate the presence of an object and
determine the object’s distance. While PreView® sensors can resolve multiple objects, only the object closest to the
vehicle is reported to the operator display since it represents the most signicant collision threat.
The amount of energy returned is based on a few factors:
Size – a larger object usually reects more energy than a smaller object.
Composition – a metal object typically reects more energy than a non-metallic object.
Scattering – a solid object reects more energy than a non-solid object such as tree branches, gravel, bushes, etc.
Shape – complex shapes cause energy to be returned in a very non-uniform way. Very small variations or movement
can change detection status.
Angle – an object at side perpendicular to the sensor will reect more energy than an object at an angle. See Figure 5
for an example of how angle can affect return energy.
APS-SUPPLY.COM
www.aps-supply.com
Figure 5. Object Reection
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
System Operation
The Side Defender® system has two different modes of operation depending on the vehicle speed.
Slow Speed ON/OFF
Models SDR8504 and SDL8504 have Slow Speed set to ON: if vehicle speed is below 10 mph (16 kph), the Side
Defender® will detect and report all objects in the sensor’s Slow Speed eld of view (6’ fore and 6’ aft of sensor).
Models SDR8503 and SDL8503 have Slow Speed set to OFF: if vehicle speed is below 10 mph (16 kph), the Side
Defender® will not report objects.
At Speed Operation
If vehicle speed is above 10 mph (16 kph), all models ignore stationary objects such as guardrails or concrete barriers,
while alerting the operator of moving objects in the blind zone 20’ fore and 20’ aft of the sensor. This feature minimizes
‘nuisance alerts’ due to stationary objects in the detection zone, e.g. guardrails, signs, etc. This mode is optimized for
on-highway blind zone collision mitigation due to lane change or merging.
APS-SUPPLY.COM
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
System Installation
The Side Defender® system has two different modes of operation depending on the vehicle speed.
Before you Start
Models SDR8504 and SDL8504 have Slow Speed set to ON: if vehicle speed is below 10 mph (16 kph), the Side
Defender® will detect and report all objects in the sensor’s Slow Speed eld of view (6’ fore and 6’ aft of sensor).
Models SDR8503 and SDL8503 have Slow Speed set to OFF: if vehicle speed is below 10 mph (16 kph), the Side
Defender® will not report objects.
Sensor Location
The Side Defender® mounting location is important for proper system operation. The sensor should be mounted on the
side of the vehicle with the bottom of the radar between 18” (45 cm) and 24” (61 cm) above the ground. The sensor face
should be perpendicular to the ground with Side Defender® text up and V logo pointing down. Select a location that will
provide some protection from impact and debris while allowing an unobstructed view of the target hazard area. Refer to
the Keep Out/Interference Zones in Figure 8.
APS-SUPPLY.COM
Figure 6. Sensor Position on Vehicle
Sensor Mounting
1. Select the appropriate location to mount the sensor in Figure 6.
2. The standard mounting conguration is with ‘Side Defender®’ text, as shown in Figure 1.
3. Using the drill template, scribe position marks through the holes. Drill 1/4” (6 mm) holes centered on the marks.
4. For the pigtail, drill a 1 1/2” (38 mm) hole for the sensor connector and mating connector.
5. Secure the sensor to the equipment using the supplied hardware, with a maximum 22 in-lbs torque.
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
Mounting Tolerances
For optimal performance, the vertical angle (up/down) tolerances are +5° (up) and -2° (down). The horizontal angle (side/
side) tolerance is +/- 5°.
APS-SUPPLY.COM
Figure 7. Vertical and Horizontal Angle Mounting Tolerances
The performance of the sensor can be negatively impacted if the sensor is angled down, causing ground and curb
detections. Any time the sensor is not perpendicular to the ground, the performance should be tested.
The sensor’s horizontal eld of view is +/- 75° and the vertical eld of view is +/- 10°. For optimal performance, the
sensor should protrude beyond any other portion of the vehicle.
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
Keep Out/Interference Zones
Metallic and other strong radar reecting objects must remain outside of the Keep Out Zones dened in Figure 8. Radar
reecting objects within these areas may affect operation. If those objects cannot be removed, testing must be performed
to determine the inuence on the system’s performance.
APS-SUPPLY.COM
Horizontal “Keep Out” ZoneVertical “Keep Out” Zone
Figure 8. Keep Out Zones
Important!
Before permanently installing the PreView® Side Defender® on the vehicle, verify that the selected sensor mounting
location provides a clear detection zone. Take the vehicle to a clear area, temporarily attach the sensor in the proposed
mounting location, apply power to the system, and verify that nothing is being detected.
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
PreView Daily Maintenance
Safety Message to Vehicle Operators with PreView Radar Systems
1. Failure to follow all safety precautions and instructions may result in property damage, serious injury, or death. It is
necessary to read, understand and follow all instructions shipped with the product.
2. Systems on operating equipment must be tested each day prior to the equipment operation. The equipment operator
must check for proper operation at the beginning of every shift or safety inspection period.
3. The PreView® system is intended as an Object Detection System and should not be relied upon as your rst line of
defense for the safe operation of the equipment. It should be used in conjunction with established safety programs and
procedures to augment the safe operation of the equipment, ground personnel, and adjacent property.
4. People’s lives depend on the proper installation of this product in conformance with these instructions. Should the
system become inoperative, it could jeopardize the safety or lives of those who depend on the system.
5. The PreView® Object Detection System is intended for commercial use. Proper installation of the object detection
system requires a good understanding of equipment electrical systems and procedures, along with prociency in the
installation.
APS-SUPPLY.COM
6. Store these instructions in a safe place and refer to them when maintaining and/or reinstalling the system.
Testing and Maintenance
NOTE: A walk around test shall be performed every day to verify proper function of the system and to familiarize the
operator with the zone of detection. More frequent inspections should be performed when:
The equipment is operating in a particularly dirty or harsh environment.
The operator has reason to suspect the system has been damaged.
This test should be performed with two people, the operator who remains in the cab, and the assistant who walks through
the sensor eld (detection zone).
1. Move the equipment to an open eld larger than the detection zone to test.
2. Clean the sensor face of any accumulation of dirt, mud, snow, ice, or debris.
3. Visually inspect the attached wiring and cable and verify that they are properly secured, not chang or dangling free
where they could become snagged and damaged. Inspect the PreView® Sensor and Operator Display and verify that
they are securely attached to the equipment.
4. Place the sensor in active mode. Make sure the equipment has been secured and remains stationary.
5. Verify the sensor is operational. Depending on operator notication, this may be: green LED (for display), green icon
(in-cab video monitor), or beep (buzzer or SAS).
6. Assure the detection zone has been cleared of all obstacles. Any obstacles in the detection zone will interfere with
the test.
7. The assistant should walk across the sensor eld while the operator notes when the warning activates, signifying the
sensor has detected the assistant and identifying the detection zone limits.
8. Next, the assistant should walk from the center of the sensor eld straight back, away from the equipment (the center
line of the detection zone) while the operator notes when the warning (notication) stops.
9. The assistant should move to a point near the center of the detection zone and remain still for a few seconds, the
warning should continue, demonstrating the system’s ability to detect a still object.
10. The assistant should walk the complete sensor eld while the operator notes the detection edges of the entire
coverage area.
11. Finally, after the test the operator and the assistant need to communicate the details on the detection zone.
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
Troubleshooting
Display Status LED is not illuminated:
• Verify that DC power (9-33V) is applied to the sensor.
• Verify that the cable between the sensor and display is connected.
Display Status LED and Detection LED are both illuminated:
• There is a system error, contact PRECO Electronics®.
Detection LED is always illuminated when sensor is mounted:
• Verify the sensor is pointing outward from the vehicle in an open area with no obstructions. This may require
removing the mounting screws and lifting the sensor out away from the side of the vehicle. If the detection LED is
not active when moved away from the vehicle, but is active when mounted, then the sensors’ mounting position will
have to be moved.
Detection LED is on frequently when driving around and there is nothing in the detection zone:
APS-SUPPLY.COM
• The sensor may be detecting a curb. Aim the sensor up about 2°and check again. Do not aim the sensor up more
than 5° from perpendicular to ground.
Detection buzzer sounds when turn signal is not active:
• The harness turn signal wire is being set by other electronics, i.e., daytime running lights, air brakes, etc. Check turn
signal wire connection.
The system is detecting stationary objects above 10 mph (16 kph):
• The sensor is not receiving speed messages over the CAN bus.
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
Range Accuracy:
Azimuth Field of View:
Elevation Field of View:
Angle Accuracy:
Velocity Range:
Velocity Accuracy:
Target Resolution:
Cycle Time:
Target Detection Time:
Power On to Active Time:
FMCW Radar @24 GHz
See Figure 9
IP69K
Polycarbonate radome
4.90” w x 4.06” h x 1.28” d (12.4 cm x 10.3 cm x 3.25 cm)
1.0 lb (0.45 kg)
-40°C to +85°C
-55°C to +105°C
25 G, random, all three axis
50 G
Four 0.22” (5.6 mm) diameter mounting holes.
Detection Zone Figure 2 – At Speed: 10’ (3 m) x 40’ (6 m)
Slow Speed: 10’ (3 m) x 12’ (3.6 m)
1.4 m for static targets, nearing 0.3 m for dynamic targets
120 ms
300 ms
300 ms
Electrical Specications Frequency:
Power Supply:
Current:
Communications Interface J1939 CAN Bus:
Alarm Output
Maintenance
Daily:
Display Specications
Connector:
Housing Material:
Dimensions:
Weight:
Regulatory Compliance Compliant with FCC
Part 15.249 FCC ID:
‘CE’ ‘E’ mark:
24.00 – 24.25 GHz
9 – 33 VDC, Reverse polarity and over-voltage protected
<0.5 A
250 Kbits/sec, not terminated
Active - Switch to ground, sink up to 1 A, over current protected
Inactive – High Impedance
Follow test and maintenance procedure
See Figure 10
Polycarbonate/ABS alloy
1.00” H x 2.25” W x 2.00” D (2.5 cm x 5.7 cm x 5.1 cm)
0.25 lb. (0.11 kg)
OXZJCKP2016
E11 10R-059618
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
PIN
SIGNAL NAME
1
BATTERY PWR (+)
2
GROUND
3
CAN HIGH
4
CAN LOW
5
DISPLAY PWR (+)
6
DISPLAY GROUND
7
N/C
8
TURN SIGNAL INPUT
2
1
7
8
3
5
6
4
CONNECTOR PIN OUT
CONNECTOR END VIEW
DEUTSCH DT06-08SA-E008
F
igure9.DeutschConnectorPinOut
PIN
SIGNALNAME
1
BATTERYPWR(+)
2
GROUND
3
CANHIGH
4
CANLOW
5
DISPLAYPWR(+)
6
DISPLAYGROUND
7
N/C
8
TURNSIGNALINPUT
PIN
SIGNAL NAME
1
CAN HIGH
2
CAN LOW
3
-
4
-
5
POWER
6
GROUND
7
-
8
-
2
1
7
8
3
5
6
4
CONNECTORPINOUT
CONNECTORENDVIEW
DEUTSCHDT06-08SA-E008
CONNECTOR PIN OUT
7
1
8
APS-SUPPLY.COM
Figure 9. Deutsch Connector Pin Out
Figure 10. Display Connector Pin Out
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
Warranty Information
MANUFACTURER STANDARD LIMITED WARRANTY AND LIMITATION OF LIABILITY
Manufacturer warrants that on the Date of Purchase this Product will conform to Manufacturer’s published specications
for the product, which are available from Manufacturer on request, and Manufacturer warrants that the product is free
from defects in materials and workmanship. This Limited Warranty for the sensor extends for sixty (60) months from the
date of shipment. Manufacturer will, at its option, repair or replace any product found by Manufacturer to be defective
and subject to this Limited Warranty.
This Limited Warranty does not apply to parts or products that are misused; abused; modied; damaged by accident, re
or other hazard; improperly installed or operated; or not maintained in accordance with the maintenance procedures set
forth in Manufacturer’s Installation and Operating Instructions.
To obtain warranty service, you must ship the product(s) to the specied Manufacturer location within thirty (30) days
from expiration of the warranty period. To obtain warranty service, call Customer Service at +1.866.977.7236 or
+1.208.323.1000, or fax your request to +1.208.323.1034. Customer Service will issue warranty authorization and further
instructions. You must prepay shipping charges and use the original shipping container or equivalent.
EXCLUSION OF OTHER WARRANTIES: MANUFACTURER MAKES NO OTHER WARRANTIES, EXPRESSED,
IMPLIED OR STATUTORY. THE IMPLIED WARRANTIES FOR MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE HEREBY EXCLUDED AND SHALL NOT APPLY TO THE PRODUCT. BUYER’S SOLE
AND EXCLUSIVE REMEDY IN CONTRACT, TORT OR UNDER ANY OTHER THEORY AGAINST MANUFACTURER
RESPECTING THE PRODUCT AND ITS USE SHALL BE THE REPLACEMENT OR REPAIR OF THE PRODUCT AS
DESCRIBED ABOVE.
APS-SUPPLY.COM
LIMITATION OF LIABILITY: IN THE EVENT OF LIABILITY FOR DAMAGES ARISING OUT OF THIS LIMITED
WARRANTY OR ANY OTHER CLAIM RELATED TO MANUFACTURER’S PRODUCTS, MANUFACTURER’S LIABILITY
FOR DAMAGES SHALL BE LIMITED TO THE AMOUNT PAID FOR THE PRODUCT AT THE TIME OF ORIGINAL
PURCHASE. IN NO EVENT SHALL MANUFACTURER BE LIABLE FOR LOST PROFITS, THE COST OF SUBSTITUTE
EQUIPMENT OR LABOR, PROPERTY DAMAGE, OR OTHER SPECIAL, CONSEQUENTIAL OR INCIDENTAL
DAMAGES BASED UPON ANY CLAIM FOR BREACH OF CONTRACT, NEGLIGENCE OR OTHER CLAIM, EVEN IF
MANUFACTURER OR A MANUFACTURER’S REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES.
Manufacturer shall have no further obligation or liability with respect to the product or its sale, operation and use, and
Manufacturer neither assumes nor authorizes the assumption of any other obligation or liability in connection with such
product.
This Limited Warranty gives you specic legal rights, and you may also have other legal rights, which vary, from state
to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
exclusion or limitation may not apply to you.
Any oral statements or representations about the product, which may have been made by salesmen or Manufacturer
representatives, do not constitute warranties. This Limited Warranty may not be amended, modied or enlarged, except
by a written agreement signed by an authorized ofcial of Manufacturer that expressly refers to this Limited Warranty.
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
PREVIEW SIDE DEFENDER II MANUAL
NOTES
APS-SUPPLY.COM
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.