Precision Rated Optics OLT-301 SERIES Operation Manual

OLT-301 S
ERIES
Optical Loss Tester
V.1.23.17
2
888-545-1254 | www.PrecisionRatedOptics.com
OLT-301 Series
Table of Contents
Safety Instructions ....................................................................................................................................................4
1. General Information ............................................................................................................................................5
1.1 Scope of this Manual ........................................................................................................................................5
1.2 Unpacking and Inspection ................................................................................................................................5
1.3 Introduction ......................................................................................................................................................6
2. Basic Operation ....................................................................................................................................................7
2.1 Foreword ..........................................................................................................................................................7
2.2 Instrument Details ............................................................................................................................................7
2.2.1 External Interfaces .....................................................................................................................................7
2.2.2 Keypad Operation ......................................................................................................................................7
2.2.3 Indicator .....................................................................................................................................................8
2.3 Use of Battery ...................................................................................................................................................8
2.4 Connector Cleaning ..........................................................................................................................................8
3. Operation ..............................................................................................................................................................9
3.1 Power On ..........................................................................................................................................................9
3.2 Stabilized Laser Source (SLS) ........................................................................................................................11
3.2.1 SLS-Laser On/Off ...................................................................................................................................12
3.2.2 SLS-Reference Setting ............................................................................................................................12
3.2.3 SLS-Setup ................................................................................................................................................13
3.3 Optical Power Meter (OPM) ..........................................................................................................................13
3.3.1 OPM-Reference Setting ...........................................................................................................................14
3.3.2 OPM-Save Record ...................................................................................................................................14
3.3.3 OPM-Recall .............................................................................................................................................15
3.3.3 OPM-Trace ..............................................................................................................................................15
3.3.4 OPM-Setup ..............................................................................................................................................16
3.4 Optical Loss Test (OLT) ................................................................................................................................17
3.4.1 OLT-Reference Setting............................................................................................................................17
3.4.2 OLT-Bi-Directional Test .........................................................................................................................18
3.4.3 OLT-Save Record ....................................................................................................................................19
3.4.4 OLT-Recall ..............................................................................................................................................19
3.4.5 OLT-Threshold Setting ...........................................................................................................................20
www.PrecisionRatedOptics.com | 888-545-1254
3
OLT-301 Series
3.4.6 OLT-Setup ...............................................................................................................................................20
3.5 Optical Return Loss Test (ORL)-Option ........................................................................................................22
3.5.1 ORL-ORL Test ........................................................................................................................................22
3.5.2 ORL-Save Record ...................................................................................................................................23
3.5.3 ORL-Recall ..............................................................................................................................................24
3.5.3 ORT-Setup ...............................................................................................................................................24
4. Maintenance and Calibration ............................................................................................................................25
4.1 Cleaning of the Connectors ............................................................................................................................25
4.2 Calibration Requirement ................................................................................................................................25
5. Warranty Information .......................................................................................................................................25
5.1 Terms of Warranty .........................................................................................................................................25
5.2 Exclusions ......................................................................................................................................................25
5.3 Warranty Registration ....................................................................................................................................26
5.4 Returning Instruments ....................................................................................................................................26
5.5 Contact Customer Service ..............................................................................................................................26
4
888-545-1254 | www.PrecisionRatedOptics.com
OLT-301 Series
Safety Instructions
Safety Terms Used in This Manual
WARNING
The WARNING sign denotes a hazard. It calls attention to a procedure which could result in personnel injury.
CAUTION
The CAUTION sign denotes a hazard. It calls attention to an operating procedure if not correctly performed or adhered to, could result in damage to or destruction of part or the entire product.
NOTE
The NOTE sign information that may be beneficial during the use and maintenance of the instrument.
WARNING
OLT-301 Series Optical Loss Tester is a laser device. U ser should always avoid direct eye exposure to the laser output. Using microscope or m ag nifier to observe the laser output should also be avoided: laser beam may converge on the retina and cause permanent eye injury.
CAUTION
Battery: OLT-301 Series battery type is lithium battery. Battery Power Supply: Do not expose battery to fire or intense heat. Do not open or mutilate battery. Avoid
touching the electroly te in th e battery, which is corrosive and may cause injuries to eyes, skin or damage to clothes.
External Power Supply: OLT-301 Series support external power supply: 5V DC/750mA. External power supply is optional.
Laser Radiation: To avoid serious eye injury, never look directly into the optical outputs of fiber optic network equipment, test equipment.
Always avoid looking directly into the optical output port, when the instrument is working.
Always replace protective dust cap on the detector port when the instrument is not in use.
Always avoid looking directly at unconnected end of optic fiber in testing and make the unconnected end
pointing at a non-reflec tiv e ob ject.
www.PrecisionRatedOptics.com | 888-545-1254
5
OLT-301 Series
1. General Information
1.1 Scope of this Manual
Thank you for purchasing a Precision Rated Optics instrument. Please read this manual carefully before using Precision Rated Optics fiber optic instrument. Always be aware of the Warning and Caution signs appearing throughout this manual.
This manual contains the information necessary for proper operation and maintenance of a Precision Rated Optics instrument, troubleshooting instructions as well as information regarding maintenance services.
All Precision Rated Optics instruments are carefully assembled and undergo rigorous mechanical, electrical, and optical inspection prior to shipment. Beside the instrument, the package also includes a lithium battery pack, a charging/data transfer cable, a power adapter, a FC/UPC adapter and this user's manual. For detailed information, please refer to the packing list.
Upon receiving the instrument, please check for any obvious signs of physical damage that may have occurred during shipment. Report any damage to the shipping agent or the representative of PRO immediately. Retain the original packing materials in case reshipment is necessary.
1.2 Unpacking and Inspection
This instrument has been carefully packed in accordance with standard shipping procedures. Examine the instrument for damage that may have occurred during shipment. If you find any damage or the instrument is not working, or if any of the following items are not included, please contact your representative of PRO.
If necessary, you may contact PRO via this email: sales@PrecisionRatedOptics.com.
NOTE
To return the instrument in the case of repair, calibration or other m ainten ance , ple ase no te the following:
Be sure to pack the instrument with soft cushion like Polyethylene, so as to protect the shell of the
instrument.
Please use the original hard packing box. If use other packing material, please ensure at least 3 cm soft
material around the instrument.
Be sure to correctly fill out and return the warranty registration card, which should inc lude the following
information: company name, postal address, contact, phone number, e-mail address and problem description.
Be sure to seal the packing box with exclusive tape.
Be sure to ship to your representative or the agent of the Company in a reliable way.
6
888-545-1254 | www.PrecisionRatedOptics.com
OLT-301 Series
1.3 Introduction
The Precision Rated Optics OLT-301 Series Intel ligen t Optic al Loss Test er combines stabilized laser source and optical power meter which can perform automatic bi-directional loss test (when used in pairs) on single fiber with Pass/Fail assessment to offer user-friendly operation and avoid potential operational mistakes. The rugged and easy-to-use OLT-301 Series is the id e al o pt ical loss tester fo r F T Tx, LA N and CA T V ap pl ic a tio n .
Features:
All-in-one: SLS + OPM + OLT + ORL + Length test
Optical power monitoring (Auto power trace)
Bi-directional loss test on single fiber
• ORL test
Pass/Fail assessment
Automatic wavelength identification/switch (AutoID)
Remote reference value setting
Internal clock & fiber S/N editable
1000 test records (CSV) storage & management
Data transfer to PC via USB (Driver-free)
Auto test records save in local unit/remote unit/both units
USB power charging
Over 35 hours continuous operation
Multilanguage support
No warm-up, quick start
High resolution color LCD
Pocketsize, lightweight and easy-to-use
Automatic Wavelength Identification
Compatible with the digital encryption protocols of its laser source module and PRO Series Stabilized Laser Source, the OLT-301 Series tester can automatically identify the wavelength of the input optical signal and switch to the corresponding test mode, which greatly reduces the workload at both ends and avoids potential error.
Automatic Bidirectional Loss Test on Single Fiber
One OLT-301 Series tester at each end of a single optical fiber can perform bi-directional loss test by just pressing one unit and can automatically measure and display the entire fiber attenuation to help users acquire complete and accurate optical fiber loss informatio n.
Applicable to FT T x /P ON tes tin g
The OLT-301 Series tester can be used to measure Triple-play signals (1310nm, 1490nm and 1550nm) on Passive Optical Network (PON)
www.PrecisionRatedOptics.com | 888-545-1254
7
OLT-301 Series
2. Basic Operation
2.1 Foreword
This part introduces the basic operation on the OLT-301 Series testers. Specific operations are elaborated in Chapter 3 of this manual. Please read this manual carefully for optimal operation. If you encounter any problems during operation, you are welcome to contact the technical staff of our company or representatives.
2.2 Instrument Details
2.2.1 External Interfaces
1. Optical Input & Output
The OLT-301 Series is available with FC connector (Interchangeable SC/ST). Note: Output port is marked with “LS”; Input port is marked with “PM”.
2. USB Power /Data Port
The OLT-301 Series can be charged by external power adapter (5V DC, 750mA).
2.2.2 Keypad Operation
Power on/off
Toggle between wavelengths
Toggle between setup items; Adjust value in setup mode
Toggle between sub-interfaces in working mode; Shift digit positions in setup mode
Toggle between working modes: SLS, OPM, OLT & ORL;
Long press to enable/disable Auto Power Off
Enter setup mode; Execute or toggle between setup values; Confirm
Short press to turn backlight on/off;
Long press to set contrast
8
888-545-1254 | www.PrecisionRatedOptics.com
OLT-301 Series
2.2.3 Indicator
Charging Indicator
Laser Indicator (Illuminate when laser emits)
2.3 Use of Battery
The OLT-301 Series works on lithium battery. Please make sure battery is mounted properly before use. When battery is low, low battery indicator will appear on LCD. You can still use the OLT-301 Series as long as its display on LCD is identifiable. When LCD display becomes dim, laser source output will become unstable and power meter measurement will be inaccurate. Please charge as soon as possible when battery is low to ensure accurate measurement.
NOTE
Please take out the battery of the OLT-301 Series if it is not in use for a long time.
2.4 Connector Cleaning
Please follow the instructions below when cleaning:
Turn off the instrument before cleaning.
Non-compliant operation may result in hazardous radiation exposure.
Turn off laser source before cleaning optical interface.
Always avoid looking directly into the optical output port when the instrument is working, laser is
invisible and can cause serious eye damage.
Disconnect instrument from power supply before cleaning to prevent electric shock.
Do not install unauthorized parts or make unauthorized adjustments on instrument.
• Please consult qualified profess ion al abou t m aintenan c e and repair se rv ices.
NOTE
Always clean the optical connectors before using the OLT-301 Series to ensure accurate measurement. Clean the optical connector gently with cleaning swab.
NOTE
Inappropriate maintenance may result in low performance or error:
• Distance error increases;
• Linearity error;
Extra optical power attenuation;
Received optical power is beyond normal range.
www.PrecisionRatedOptics.com | 888-545-1254
9
OLT-301 Series
3. Operation
3.1 Power On
Press and loading screen appears Then it enters functional interface ( The last int er face be fore last shut do wn), see F ig ure 3.2.
Figure 3.2
The toggle between functional interfaces:
Press to toggle [Main menu] interface, see Figure 3.3.
Figure 3.3