Precisionary Compresstome VF-310-0Z User Manual

Compresstome® VF-310-0Z User Manual
1
Thank You
Thank you for choosing the Compresstome® VF-310-0Z!
At Precisionary Instruments, we are thrilled to help you get started with your new vibrating microtome, and we take great pride in quality customer service. Please read the following manual to help you get started with the Compresstome® VF-310-0Z.
Note
The information, numerical data, notes and value judgements contained in this manual represent the current state of scientific knowledge and state-of-the-art technology. We aim to update the present manual regularly and on an ongoing basis according to the latest technical
developments. Please contact us or visit our website to find the latest versions of this user
manual.
Contact info@precisionary.com for updated information.
Website: www.precisionary.com
2
Table of Contents
Thank&You&................................................................................................................................................................................&1&
!
Part!1:!Introduction!.............................................................................................................................!3!
Safety&..........................................................................................................................................................................................&4&
Model&Description&................................................................................................................................................................&5&
Technical&Specifications&.....................................................................................................................................................&6&
Model&Components&..............................................................................................................................................................&7 &
Control&Box&Anatomy&..........................................................................................................................................................&9&
Accessories&...........................................................................................................................................................................&11&
Starter&Kit&Components&...................................................................................................................................................&12&
!
Part!2:!Setup!........................................................................................................................................!13!
IMPORTANT!&How &t o&R e p la ce &th e &V ib ra tio n &H ea d &..............................................................................................&14&
Mounting&the&Cutting&Blade&to&the&Blade&Holder&.................................................................................................&19&
Preparing&Agarose&for&Embedding&.............................................................................................................................&25&
Cutting&Parameters&Guideline&......................................................................................................................................&26&
Embedding&Tissue&in&Agarose&......................................................................................................................................&28&
!
Part!3:!Operation!...............................................................................................................................!30!
Sectioning&with&the&Compresstome®&Tissue&Slicer&............................................................................................&31&
!
Part!4:!General!Information!...........................................................................................................!33!
Cleaning&and&Maintenance&.............................................................................................................................................&34&
Buffer&Tray&Maintenance&and&Cleaning&....................................................................................................................&36&
Auto&Zero-Z®&Technology&.............................................................................................................................................&37&
Troubleshooting&.................................................................................................................................................................&38&
Warranty&Information&.....................................................................................................................................................&41&
Contact&Information&..........................................................................................................................................................&42&
3
Part 1: Introduction
4
Safety
Dangers, warnings, and cautions appear in a box and are marked by the warning triangle.
Important information for the user, such as disclaimers, appear in a box and are
marked by the information symbol.
Caution! Follow the accompanying documentation.
5
Model Description
The VF-310-0Z tissue slicer model is the latest version of our flagship product in the Compresstome® slicer family. With patented Auto Zero-Z® technology, the VF-310-0Z is fully automated to section both fixed and live tissues with a thickness range of 4 µm* to 1000 µm and an adjustable precision of 1 µm.
The Compresstome® VF-310-0Z excels at sectioning slices used for:
Electrophysiology
Immunohistochemistry
Organotypic culture slices
Precision cut tissue slices
Sectioning of mature or older brain tissues
And much more!
*Slice thickness minimum depends on tissue sample and organ system.
6
Technical Specifications
Advance Speed
0-20 mm/s, adjustable
Return Speed
20 mm/s
Vibration Frequency
0-45 Hz, adjustable
Vibration Amplitude
2 mm
Z-axis Vibration
~0 µm
Compatible Blades
Stainless Steel, Ceramic, Tungsten Carbide, Sapphire Diamond
Cutting Angle
15 degrees (no need for blade alignment)
Thickness Adjustment
Automatic
Micrometer Resolution
1 µm
Maximum Tissue Diameter
6.5mm (small), 12.5 mm (standard), 15.5 mm (large), 22mm (extra large)
Maximum Tissue Length
3 mm
Minimum Slice Thickness
4 µm*
Cutting Mode
Single or Continuous
Cutting Bath
140 x 60 x 30 mm
Power Source
120 V AC
Power Consumption
18 W
Dimension ( L x W x H )
330 x 240 x 190 mm
Weight
5 kg
*Depends on tissue type and organ system.
7
Model Components
(1)$Blade$Holder
(2)$Buffer$Tray
(3)$Vibration$Head
(4)$Specimen$Tube
(5)$Control$Box
(7)$Tissue$Advancement$Plunger
(8)$Buffer$Tray$Plug
(1)$Blade$Holder (2)$Buffer$Tray
(3)$Vibration$Head
(5)$Control$Box
(6)$Transportation$Fixture
(8)$Buffer$Tray$Plug
8
Figure'Number'
Compresstome'Part'
Part'Number'
Function'
1
Blade Holder
VF-BH-VM-310-0Z-NC
Holds and stabilizes the cutting blade
2
Buffer Tray
VF-BT-VM-LP-BOS
Holds buffer or solutions during sectioning
3
Vibration Head
VF-VHU-VM-310-0Z-NC
Blade oscillation assembly, which includes a blade holder, and an oscillation motor
4
Specimen Tube
VF-SPS-VM-6.5-BOS VF-SPS-VM-12.5-BOS VF-SPS-VM-15.5-BOS
VF-SPS-VM-22-BOS
Four different tube sizes (6.5, 12.5, 15.5, and 22 mm in diameter) that hold the specimen for sectioning and embedding tissue in agarose
5
Control Box
--
Controls for the cutting speed, oscillation frequency, and desired thickness in microns.
6
Transportation Fixture
--
Stabilizes vibration head for safe transport
7
Tissue Advancement
Plunger
--
Pushes the specimen tube forward for sample to be cut
8
Buffer Tray Plug
VF-BT-PL-BOS
On/off knob to keep solution in buffer tray and easily remove solution when needed
9
Control Box Anatomy
(1)
(2)
(3)
(4)
(5a)
(5b)
(6)
(7)
(8)
(9)
(10)
(11)
(12a)
(12b)
(13)
10
Figure'Number'
Control'Box'Part'Name'
Control'Box'Function'
1&
Slice&Count&Display&Screen&
Displays&how&many&slices&have&been& cut&in&a&cutting&cycle&
2&
Total&Amount&Sectioned&(in&µm)&
Displays&the&total&amount,&inµns,& of&tissue&that&has&been§ioned&since& you&began&to&cut&in&a&cycle&
3&
Current&Slice&Thickness&(in&µm)&
Displays&the&thickness&range&your&VF­310-0Z&will&cut&slices&to&(in&µm)&
4&
Tissue&Advancement&Plunger&
Advances&the&specimen&tube&forward& after&each&slice&is&made&
5a&
Fast&Forward&Function&
Moves&the&tissue&advancement& plunger&forward,&towards&the& specimen&tube.&Use&this&function&to&get& the&tissue&advancement&plunger&to& touch&the&end&of&the&specimen&tube& before&you&begin&a&cutting&cycle&
5b&
Fast&Reverse&Function&
Moves&the&tissue&advancement& plunger&in&reverse,&for&easy&removal&of& the&specimen&tube&from&the&buffer& tank&
6&
Start&Button&for&Sectioning&
The&button&that&will&start&your& sectioning&after&turning&the&machine& one&and&setting&your&settings&&
7&
Knob&that&Controls&Speed&Setting&
Knob&that&will&control&how&fast&the& blade&holder&moves&on&the&cutting& track&
8&
On/Off&Switch&
Turns&the&VF-310-0Z&on&and&off&
9&
Reset&Button&
This&reset&button&is&for&resetting&the& total&number&ofµns&cut&in&a& cutting&cycle&
10&
Knob&that&Controls&Oscillation&
Setting&
Knob&that&will&control&the&oscillation& frequency&of&the&blade&h o lde r&a s&it&c uts &
11&
Knob&for&Slice&Thickness&Setting&
Use&this&knob&to&adjust&your&desired& slice&thickness&for§ioning&
12a&
Single&Cutting&Mode&
Single&cutting&mode&will&only§ion& one&slice&at&a&time&
12b&
Continuous&Cutting&Mode&
Continuous&cutting&mode&will§ion& continuous§ions&in&a&row&
13&
Stop&Button&for&Sectioning&
The&button&that&will&stop&the&vibrating& head&wherever&it&is&along&the&cutting& track&
11
Accessories
Figure'Number'
Compresstome'Part'
Part'Number'
Function'
1
Chilling Block
VF-VM-CB-6.5-BOS VF-VM-CB-12.5-BOS VF-VM-CB-15.5-BOS
Rapidly chills agarose in specimen tube for sectioning with the Compresstome
2a
Specimen Tube: White
Plunger
VF-SPS-VM-6.5-BOS VF-SPS-VM-12.5-BOS VF-SPS-VM-15.5-BOS
VF-SPS-VM-22-BOS
Where tissue specimen is glued onto
2b
Specimen Tube: Metal
Tube
End with tapered lip for compression technology­white plunger will move through the metal tube for sectioning
3
Acetone Bath for Blade
Holder
VF-VM-AB
Use to remove glue from the blade holder before reapplying a new blade
4
Allen Wrench for Blade
Holder
VF-BH-VM-AW
Use to remove and tighten the small screw on the blade holder when taking it on/off the machine
5
Power Cord
VF-VM-PC-BOS
Power cord for the VF-310­0Z model
(1)$Chilling$Block (2a)$Specimen$Tube:$
White$Plunger
(2b)$Specimen$Tube:$ Metal$Tube
(3)$Acetone$Bath$ for$Blade$Holder
(4)$Allen$ Wrench$for$ Blade$Holder
(5)$Power$Cord$
12
Starter Kit Components
Note: All of our Compresstome® consumables can be ordered online at:
http://precisionary.com/e-store/
Contact us directly at info@precisionary.com, and we will send you a quote.
Consumable
Part Number
Quantity
Description
Agarose Tablets
VF-AGT-VM-10
10
Low melting agarose for embedding tissue.
Blades
VF-BL-VM-SSB
10
Double-edged stainless­steel blades.
Pipettes
__
4
Plastic, disposable pipettes included for easy transfer of agarose into the specimen tubes for embedding.
Glue
VF-VM-GLUE
1
Used for securing blades to the blade holder and tissue specimens to the specimen tube.
Forceps
VF-VM-FORCEPS
2
Small forceps for easy manual manipulation of tissue sample.
Petroleum Jelly
VF-VM-PJ
2
Petroleum jelly recommended for application to the inside of the tube adapter to help prevent minor leaks for Compresstome slicer buffer trays (0.16 ounces each packet)
Loading...
+ 30 hidden pages