RS8731ECZ –MSF Operation Instruction
Function
Operation
TIME
ALARM
UP
DOWN
ALERT
SNOOZE /
LIGHT
CHANNEL
MAX / MIN
Click
------------
Select Alarm
mode
On/Off
AL1/AL2
°C/°F switchable
On/Off
Temperature
Alert
Turn on back
light
/Enter
snooze state
Switch among
CH1,CH2
and CH3
Show Max/Min
Data
Standard
Mode
Hold
Enter clock
settings
Enter alarm
setting
------------
Enter RCC Receiving-
Enter
Temperature
Setting
------------
Clear current
registered
channel
Clear
Temperature
&Humidity
Max /Min Data
Click
Confirm
settings
------------
One step
advance
One step
backward
------------
Turn on back
light
------------
------------
Time
Setting
Hold
------------
------------
8 steps
advance per
second
8 steps
backward per
second
------------
------------
------------
------------
Click
------------
Confirm
setting
One step
advance
One step
backward
------------
Turn on back
light
------------
------------
Alarm
Setting
Hold
------------
------------
8 steps
advance per
second
8 steps
backward per
second
------------
------------
------------
------------
Click
------------
------------
------------
------------
------------
------------
Confirm setting
------------
Temperature Alert Setting
Hold
------------
------------
8 steps
advance per
second
8 steps
backward per
second
------------
------------
------------
------------
I. Main Functions:
1. Weather forecast
2. Eight languages to show the days of the week
3. Indoor temperature and humidity display
4. Outdoor temperature & humidity via wireless transmitter (radio frequency up to 3 channels)
5. °C/°F selectable
6. Alarm including snooze
8. Indoor humidity range: 20% to 99%
II. Power-On and reset
1. Normal state after battery insertion clock checks temperature and humidity 3 minutes of radio
frequency receiving
2. Calendar default: 0:00 January 1, 2011
3. Temperature unit default:
4. Time default: 12 Hr
5. Alarm default: AM 12:00
Key Functions
Normal Setting
1. Hold “TIME” for 2 seconds to enter into time setting.
2. Hold “ALARM”, Select AL1AL2normal mode.
3. Hold “ALARM” for 2 seconds to enter into Alarm setting.
4. Press “UP” to turn on Alarm 1 turn on Alarm 2 turn on Alarm 1 & Alarm 2 at the same time turn
off Alarm 1 & Alarm 2.
5. Press “DOWN” to switch between °C/°F.
6. Press “SNZ/LGT” to turn on the back light 5 seconds, keep pressing “SNZ/LGT” for 2 seconds, enter sleep
setting time ,time setting range 5-30 minutes.
7. When alarm is ringing, press ”SNZ/LGT” to enter into 5 minutes snooze function.
8. Press “Channel” to switch RF channel, CH1 CH2CH3.
9. Hold “Channel” key for 2 seconds to clear out all data of current Channel.
10. Press “Alert” to turn on/off Temperature Alert.
11. Hold “Alert” for 2 seconds, enter Temperature Alert Setting.
12. Press “MAX/MIN” to check Temperature & Humidity Max/Min Data.
13. Hold “MAX/MIN” for 2 seconds, clear all data for Temperature and Humidity.
Time set
1. Hold “TIME” key for 2 seconds to enter into time setting.
2. The sequence of time setting: Year (2000-2050) Month Date Language 12/24 hour
selectableHour Minute Exit
3. The setting item will flash.
4. Press “TIME” to confirm the setting.
5. Press “UP” one time, the setting will go ahead for one step; hold the key for 2 seconds, it will run forward
by 8 steps/second.
6. Press “DOWN” one time, the setting will backward for one step; hold for 2 seconds, it will run backward
by 8 steps/second.
7. The system will exit automatically if no key is operated in 8 seconds.
8. Language setting sequence: English, German, Italian, French, Netherlands, Spanish, Danish, Russian.
9. The setting item will flash, when setting year, second will show Yr.
10. Moon phase and week will change according to the changing of the Year, Month and Date.
Alarm set
1. Hold “ALM” key for 2 second to enter into alarm setting.
2. The sequence of alarm setting: Hour Minute Exit
3. The setting item will flash.
4. Press “ALM” to confirm the setting.
5. Press “UP” once, the setting will move to the next step; hold the button for 2 seconds and it will move
forward by 8 steps.
6. Press “DOWN” once, the setting will revert to the previous step; hold the button for 2 seconds and it will
move backwards by 8 steps.
7. The system will exit automatically if no button is operated within 8 seconds.
8. Alarm function will be confirmed after setting ALARM.
9. Turn on Alarm to show small bell image.
Temperature and Humidity Setting
1. Temperature Alert function for Indoor and Outdoor Temperature.
Hold “Alert” for 2 seconds to enter ALERT Setting.
2. Press “Channel” to switch channels when setting the outdoor temperature limit.
3. The setting item will flash.
4. Press “Alert” to confirm the setting.
5. Press “UP” once, the setting will move to the next step; hold the button for 2 seconds and it will move
forward by 8 steps.
6. Press “DOWN” once, the setting will revert to the previous step; hold the button for 2 seconds and it will
move backwards by 8 steps.