Pream-I-Air EH1230 User Manual

User Guide EH1230
EH1230
8500BTU/h Class A
Portable Air Conditioner
2 cooling and 2 fan speed settings
24-hour timer
Adjustable louvre
Easy to install - no external unit required.
Page 1
User Guide EH1230
IMPORTANT
Installer and Users please note:
These instructions should be read carefully and left with the user of the product for future reference.
INSTALLATION.
Install the EH1230 on floor
approximately 36cm (14") from a wall. Ensure that the air inlets (on the sides) and the air outlets (on the top) cannot be covered.
Expand a small section of the exhaust tube, and screw it
clockwise into the it the end of the exhaust port of the unit. Place the other end of the exhaust tube into the adaptor and through the nearest open window. Keep the length of the exhaust tube to a minimum. Use the
Page 2
User Guide EH1230 foam strip provided to block the rest of the window opening.
This is essential for efficient cooling. The correct installation of the exhaust tube is shown below:
If the exhaust tube needs bending, do not bend too sharply, or more than is required.
Do not vent the exhuast tube into a ceiling void. The exhaust air may be very humid and can damage ceiling tiles.
Connect the air conditioner to the nearest 13A mains socket using the built-in cable. Do not connect using an extension lead, unless the extension lead is rated at least 6 Amps, and is fully unwound.
Do not install the air conditioner in a damp environment (such as a laundry room). The air conditioner is for indoor use only.
Do not install in direct sunlight (to avoid discolouration of the
Page 3
User Guide EH1230 case).
Do not install close to a source of heat. The EH1230 is not suitable if the ambient temperature is
below 18°C or above 35°C.
Installing the carbon filter:
1. Remove the filter frame from the unit.
2. Remove the carbon filter from its plastic bag
3. Insert the carbon filter into the back of the unit.
4. Re-fit the filter frame.