G3L-1900-54/G3L-1900-54-A Installation & Service Manual
Appendix A. Specifications
Table A-1 G3L-1900-54/54-A Wideband Multicarrier Cellular Amplifier Functional
Specifications
Frequency Range 1930 - 1990 MHz (60 MHz Bandwidth)
Instantaneous Bandwidth 20 MHz *
Total Typical / Maximum Input Power -15.7 - +4.8 / +5.8 dBm
Total Output Power 54 W (47.3 dBm)
Adjacent Channel Leakage Power
Ratio (ACLR) Spectrum Analyzer settings: 30 KHz RBW, 300 KHz VBW,
True RMS detector
RF Gain 40 dB +0.5 dB
Gain Flatness
Output Protection Mismatch Protected
Input Port Return Loss 18 dB min
Harmonics Better than -50 dBc
Out of Band Spurious Better than -60 dBc
Duty Cycle Continuous
DC Input Power:
G3L-1900-54
AC Input Power:
G3L-1900-54-A
Operating Temperature -10 ºC to +50 ºC
Storage Temperature -40 ºC to +85 ºC
Operating Humidity 0 % to 80 % Relative Humidity (noncondensing)
Storage Humidity 0 % to 100 % Relative Humidity (noncondensing)
AC, DC Input, Summary Alarm, Base
Station Communication TLCI Bus
RF Input Connector SMA Female
RF Output Connector Type N-Female
Power Consumption DC Version: 310 Watts @ Po = 30 W average power
Weight 28 lbs.
Dimensions 3.125” High, 16.75” Wide, 14.125” Deep, 15.75” Deep
* The command received from the base station includes the operating band and based on that
band, the pilot frequency sets to 10 MHz lower than the lowest carrier in the operating band.
ACLR1 <-46dBc@f=fc ±5 MHz
ACLR2 <-51dBc@f=fc ±10 MHz
±0.5 dB
-48 Vdc nominal, 6.5 amps typical (15 amps max)
Operational -57 Vdc to -60 Vdc (Po derated outside
normal operating range)
230 Vac nominal, 50/60 Hz, 1.9 amps typical (3 amps
max)
Operational 264 Vac to 300 Vac (Po derated outside
normal operating range)
Elcon Modular Flatpaq tm
AC Version: 325 Watts @ P
including connector guides
= 30 W average power
o
All specifications are subject to change without notice. Contact the factory for complete performance data.
044-05135 Rev. A
Copyright Powerwave Technologies, Inc., April 2003. All rights reserved
A-1 April 2003