powertronics PQR D52, PQR series User Manual

PowerTronics
PQR Series
Model D52
User’s Manual
PowerTronics
143 Raymond Road - Box 735
(603) 483-5876
http://www.powertronics.com
PQR
Series Model D52
Page 2
All information and specifications written or implied
in this manual are current at the time of printing. However due to ongoing process of adding improvements to the products, PowerTronics / Eastern Time Designs, Inc. reserves the right to make changes at any time without notice.
Copyright 2010
EASTERN TIME DESIGNS, INC.
The power cable attached to the device is supplied with a safety and reference ground. Do not use the PQR D52 when powered from an ungrounded outlet.
High voltage exists at many points inside the cabinet. Qualified personnel ONLY! should open the covers. Opening the covers may affect the warranty.
SAFETY NOTICE
www.Powertronics.com
V2.1
PQR
Series Model D52
Table of Contents
PQR D52
Table of Contents 3 Warranty 5 Introduction 6 Calibration 7 Features 8 Testing with the PQR D52 9 Power Up Sequence 10 Connecting to the PQR D52 11
PQR Host Communications Software
Installing the PQR Host Communications Software 13 File Menu 15 View Menu 16 Settings Menu 17 Communications Menu 20
Other Terminal Communications
PQR D52 Commands 27
C0 - Transmit the Command Menu 28 C1 - Transmit the Version Number 29 C2- Transmit a Summary Report 30 C3 - Transmit a Detail Report 31 C4 - Transmit a Data Log 32 C5 - Clear all events, and data log 33 C6 - Set the Date and Time 34 C90 - Continuous Voltage readings 39 CX - Hang up the Phone 40
Page 3
www.Powertronics.com
V2.1
PQR
Chapter 3 (Specifications)
Channel Specifications: 41
Temperature & Humidity Specifications 42 Operating Specifications: 43 Mechanical Specifications: 43 Interface Specifications: 43
Chapter 4 (Power Terminology)
Types of Power Problems 44 Dropout - Power Failure 45 Sag 46 Impulse 47 Common Mode Noise 48 Surge 49 High Frequency Noise 50
Series Model D52
Page 4
www.Powertronics.com
V2.1
PQR
Series Model D52
Page 5
18 MONTH WARRANTY
Eastern Time Designs, Inc. (PowerTronics ) warrants to the original retail purchaser that each PQR D52 SERIES Power line analyzer sold by PowerTronics or any authorized representative is free from defects in material and workmanship for 18 MONTHS from date of purchase.
In the event of malfunction or other indication of failure attributable directly to faulty workmanship and/or materials, Eastern Time Designs, Inc. (PowerTronics) will at its option, repair or replace the defective product, to whatever extent it shall deem necessary to restore the product to proper operating condition, provided the purchaser includes proof of the date of purchase of the product along with the defective product.
Please note that Eastern Time Designs, Inc. may replace the defective product with a new or re-manufactured functionally equivalent product of equal value.
Before returning a product for repair, the customer must contact Eastern Time Designs, INC. (PowerTronics ) Customer Service by opening a trouble ticket online at www.powertronics.com. This ticket number should be included with the customer's mailing address and telephone number when the product is returned. Products should be returned to:
PowerTronics: Ticket # Attention : CUSTOMER SERVICE DEPARTMENT, 143 Raymond Rd. Candia, NH 03034.
During the first 18 months after the date of purchase, all labor and materials will be provided without charge. There shall be no warranty for either parts or labor after the expiration of 18 months from the date of purchase.
The customer shall be solely responsible for the failure of any Eastern Time Designs product, or component thereof resulting from accident, abuse, or misapplication of the product, and Eastern Time Designs assumes no liability as a consequence of such events under the terms of this warranty. Some states do not allow the exclusion of implied warranties, so the above exclusion may not apply to you. This warranty gives you specific legal rights and may also have other rights which vary from state to state.
www.Powertronics.com
V2.1
PQR
Series Model D52
Page 6
INTRODUCTION
This reference guide is designed to aid PQR D52 users in the interpretation of AC power line problems.
The PQR D52 monitor is made in the U.S.A. by PowerTronics. This unit will detect a wide range of power disturbances including spikes, sags, surges, common mode noise, dropouts, and high frequency noise on the Hot and Neutral line. The PQR D52 will also monitor Temperature and Humidity
The PQR D52 is one of a series of practical power line monitors, designed and priced to be outfitted to everyone who services or installs three phase electrical, and electronic equipment.
Electronic equipment is damaged more often by power disturbances than by fire, theft, and vandalism combined. Intermittent power problems are the most expensive hidden expense to the owners of microprocessor based equipment.
The PQR D52 is easy to use and provides immediate and long term information for the technician and customer to understand power line disturbances.
To monitor the AC line with the PQR D52, plug the line cord provided into a standard 110 volt or 220 volt outlet. After running an internal self test, the unit will start testing the Hot and Neutral line and the Temperature and Humidity.
www.Powertronics.com
V2.1
PQR
Series Model D52
Page 7
CALIBRATION
The PQR D52 monitors are designed to test the Power Line with a high degree of accuracy. In this unit all measurements are referenced to a state of the art, temperature compensated voltage source. It is recommended that each unit be calibrated annually by the factory as certain components may require calibration. The procedure typically takes seven days and will be provided upon request for a nominal fee. Mention CALIBRATION PROCEDURE when calling for an RMA number.
www.Powertronics.com
V2.1
PQR
Series Model D52
Monitor 2 AC Channels
Hot and Neutral + Humidity and Temperature
User - Friendly Programmable Multiple Phase Monitoring Fast Impulse Detection Easy to Understand Reports Made in USA
The PQR D52 Power Line Analyzer provides a complete analysis of your AC Power for a fraction of the cost of other Monitors. Disturbances detected on the Hot and Neutral Lines , as well as Temperature and Humidity channels are recorded by their time, date, magnitude, and duration in a non-volatile RAM memory. This data is then retrieved
from the analyzer through it’s serial communications
port. The power to operate the unit comes from any standard 110v / 220v AC outlet. Once plugged in, the PQR D52 immediately begins testing the signals on the input connectors.
Page 8
In addition to full Text Detail and Summary reports, event information such as the Magnitude, Time, and Date of each of the disturbances is also reported.
GRAPHICS SOFTWARE
INCLUDED!
Provided with the PQR D52 is the PQR HOST COMMUNICATIONS Software.
This software allows you to easily download the data and display or print the DATALOG chart over time, the PIE CHART of the summary of events or the HISTOGRAM of the detail of events.
Features
Measures all types of disturbances
* Spikes * AC Voltage * Sags * Common Mode Noise * Line Frequency * High Frequency Noise * Dropouts * Power Failures * Surges * Temperature * Humidity
Simple to operate
1) Plug the power cord into a grounded outlet
2) Periodically connect to a computer for reports
Stores Disturbance events in non-volatile RAM
* 32,000 Events in all * Will Data log all channels up to 32,000 readings (22.75 Days @ 1 sample per minute)
www.Powertronics.com
V2.1
PQR
Series Model D52
Page 9
Testing with the PQR D52
The PQR D52 Single phase Voltage Power Quality Recorder is designed to obtain the maximum amount of useful data from the circuit under test, while requiring the minimum amount of setup time.
Data from the Hot, and the neutral line starts being collected as soon as power is applied to the AC power connector located on the back of the unit. Data will continue to be gathered until the unit is unplugged.
Long term voltage testing is known as Data Logging. The PQR D52 samples the voltage on each of the 4 inputs continuously, and stores the average voltage once each minute. There is enough data storage capacity in the unit to collect these readings on all 4 input channels for up to 20 days at 1 minute per sample.
The PQR D52 will continuously test the Hot and Neutral inputs for Sags, Surges, Power Failures, Dropouts, Impulses, High Frequency Noise, Line Frequency, and Phase changes. Any power quality problems that exceed the preset thresholds will be recorded in FLASH RAM, with the time and date stamp of the event. There is enough data storage capacity in the unit to collect up to 32,000 of these readings.
www.Powertronics.com
V2.1
PQR
Status LED
Series Model D52
Page 10
Apply AC Power:
There is a Unit Status LED on the front of the PQR D52. This led is used to indicate system diagnostics status, and Unit operational status.
When the PQR D52 is first connected to AC power (110VAC or 220 VAC), it will go through a series of power on diagnostics. The status of these tests can be seen in the Status LED located on the front panel. While the initial tests are being executed, (approximately 10 seconds long) the Red LED will be blinking. After the tests are completed, the LED will turn off briefly, and then turn on steady.
The LED will blink for ten seconds, whenever there is a disturbance detected on any input, or the serial port has been accessed.
As soon as the diagnostics have completed, the PQR D52 is on-line, and monitoring the Hot and Neutral lines, the Temperature channel, and the Humidity Channel. The unit should be left on-line testing for at least a 72 hour period.
www.Powertronics.com
V2.1
PQR
Series Model D52
Page 11
Connecting to the PQR D52
USB:
The USB port on the back of the PQR D52 can be directly connected to the USB port on your computer. The PQR D52 will register on the USB port as an additional communications port (COM X)
The USB driver for this port is a standard part of Windows ™ XP, Vista and Seven operating
systems. The driver is also available from the help desk at www.powertronics.com
Connect to the USB port using the USB A/B cable provided with the unit.
RS232 Port:
Some computers are equipped with an RS232 port and the PQR D52 is enabled for communications with this port as well. (Note, only one port on the PQR D52 can be utilized at a time).
The serial port connector on the back of the PQR D52 is a 9 pin DB style RS232. The pinout is as follows:
Pin 2 Receive Data Pin 3 Transmit Data Pin 5 Ground
A Null modem cable (provided) must be used to establish a connection between this port and a PC. This type of cable connects the Transmit Data pin on the PC to the Receive Data pin on the PQR D52, and the Transmit Data pin on the PQR D52 to the Receive Data pin on the PC. It also connects the Ground pins together.
Connect to the RS232 port using the Null modem cable provided with the unit.
The PQR D52 is configured to operate at 19,200 baud, with 8 data bits, 1 stop bit, and no parity checking. Select Xon/Xoff Communications protocol.
www.Powertronics.com
V2.1
PQR
PQR Host Communications Software:
The PQR D52 is provided with the Powertronics Host Communications Software. When the PQR D52 is connected to a computer with a null modem cable, the Host software provides several functions:
Automatically connect to the PQR D52 Configure the PQR D52’s settings Download data from the D52 and Save on the computer Generate Reports, Charts and Graphs from the downloaded data
Series Model D52
Page 12
www.Powertronics.com
V2.1
PQR
Series Model D52
Page 13
Installing the PQR Host Communications Software
Go to www.powertronics.com, click on the support link and download the latest version of the software Or: Put Disk 1 provided with your unit into your disk drive.
Select or Double click on SETUP
A series of files will be copied to your computer’s RAM
To prevent any software conflicts, you should close any other applications programs running before continuing with the PQR Host software installation, then click on OK.
Click on the Computer Button to start the installation.
www.Powertronics.com
V2.1
PQR
The PQR Host communications software can now be started.
Click on START Select PROGRAMS Select POWERTRONICS
Series Model D52
Page 14
Clicking on CONTINUE will allow the installation to complete.
This Screen is the starting point for working with the PQR D52.
www.Powertronics.com
V2.1
PQR
Series Model D52
Page 15
File Menu
The "File" menu contains options for using data files that are stored on disk.
Open
Select the "Open" menu item to open a data log, detail report, or summary report that is stored on disk. After specifying the desired file, the program will open a window that contains the data from the file.
Close
Select the "Close" menu item to close the active window.
Print
Select the "Print" option to send the active window to a printer. This menu item will display a Print Dialog for the user to select which printer to use and to specify the desired settings.
Memory Files
The program will keep track of the last four files that have been used, and keep their names and locations in memory. To reopen any of these files, simply select the menu item with the desired file's name. The program will display the contents of the file in a new window.
Exit
Select the "Exit" menu item to close all windows and exit the program.
Other options that are sometimes shown:
Save
Select the "Save" menu item to save the active data file to its current file name and location.
Save As... Select the "Save As..." menu item to save the active data file to a new file name and location.
www.Powertronics.com
V2.1
PQR
Series Model D52
Page 16
View Menu
The "View" menu contains items used to control what tools are visible and available to the user in the main program window.
Toolbar
Select the "Toolbar" menu item to toggle the toolbar. The toolbar contains the buttons for opening and printing files.
Status Bar
Select the "Status Bar" menu item to toggle the status bar at the bottom of the main program window. The status bar displays the program's current COM port and baud rate settings.
www.Powertronics.com
V2.1
PQR
Series Model D52
Page 17
Settings Menu
The "Settings" menu contains items that allow the user to specify certain settings for communication between the software and the PQR device. The menu also provides an interface for setting the PQR device parameters.
COM Port 1 - COM Port 4
The "COM Port" menu items are used to specify which computer COM port the PQR device is connected to. Selecting one of the options will change the program setting to that particular port. The current settings are indicated by a check mark next in the Settings menu. The current COM port setting is also displayed in the status bar at the bottom of the main program window.
Set Date/Time
Select the "Set Date/Time" menu item to set the device date and time.
A dialog box will be displayed that provides the user an interface with which to specify the date and time. The settings will be defaulted to the current date and time, or to the date and time specified previously in the same program session.
After inputting the desired date and time, pressing the "Okay" button will instruct the program to set the device to the specified settings. This process may take a few seconds.
www.Powertronics.com
V2.1
PQR
Set Baud Rate
The "Set Baud Rate" menu option allows the user to specify the data rate to be used when communicating with the device. The program will display a dialog box with the six valid baud rates to select from: 1200, 2400, 4800, 9600, 14400, 19200 and 38400. After selecting the desired baud rate, pressing the "Okay" button will instruct the program to set the device baud rate. This process may take a few seconds. The program baud rate setting will also be set to the selected setting.
When the rate is changed, the new setting is saved in FLASH RAM, and is used as the power up default until the next time the setting is changed.
Series Model D52
Page 18
www.Powertronics.com
V2.1