1. In Electricity Rate setup page, “KWHƖRATE” in looping display represents cost
of KWH of your electricity rate.
2. The rate value blinks. Use the arrow key to change the rate value.
3. Press the SET button to proceed to Carbon Emission setup page.
Carbon Emission Setup
Carbon dioxide is emitted in the process of producing electricity by burning coal &
fossil fuel. This is usually referred to CO2 footprint or carbon emission, which in
1. In Audible Alarm setup page, “ALRMƖON” displays in looping.
2. The YES [YS] option blinks first. Use the arrow key to select Yes or NO to enable
or disable audible alarm for surge and event alert.
3. Press the SET button finish the initial setup and the page will proceed to default
Channel mode automatically.
turn has contributed global warming and caused abnormal weather.
The average carbon emission rate is 0.43Kg (0.95lbs) of carbon emission for every
1 KWH of electricity produced. This can be changed depending upon your local
electric utility. Please contact your local utility for carbon emission rate.
Energy Monitor Display Mode
The energy monitor provides 6 types of display modes. Press the MODE button to
scroll thru different display modes.
2. The Kg symbol blinks first. Use the arrow key to select the weight symbol in Kg
3. The carbon emission rate blinks. Use the arrow key to change the value. Press
or LB. Then press the SET button to proceed to carbon emission rate setup.
1. In Carbon Emission Setup page, “CO2ƖSETƖUP” displays in looping.
the SET button to proceed to Audible Alarm setup page
V1.
n
i
r
l All V
n
WERLINK M
REEN P
13
0
0
Energy Mode
16
Historic Energy
Consumption in kWh
REEN POWERLINK Manual All Versions V1.
Proj ected Energy
Consumption in kWh
Energy
Consumption in kWh
1. View energy consumption in kWh for the channel
In Energy Mode, the energy monitor will first display the energy consumption in
kWh for the Channel.
2. View projected energy consumption for the channel
The energy monitor can calculate and display the projected energy consumption.
Use the right arrow key to change from energy consumption in kWh to projected
energy consumption PER DayƖPER WeekƖPER MonthƖPER Year.
3. View historic energy consumption for the channel
energy consumption LAST DayƖLAST WeekƖLAST MonthƖLAST YearƖTo tal
the right arrow key to change from projected energy consumption to historic
(up to date).
The energy monitor can store and display the historic energy consumption. Use
Channel Mode (Default page)
The energy monitor will return to the default Channel Mode page when it is idle for
30 seconds.
1. Change channel in channel mode
The energy monitor can control and monitor up to 9 energy tracking surge
protectors. Each CH number represents an energy tracking surge protector.
Use the arrow key to change the channel from CH1 to CH9 to ALL channels.
2. View instant energy consumption of each channel
The energy monitor can display instant energy consumption in watt of each channel.
When CH number is changed to ALL, the energy consumption of ALL available
Channels will be displayed.
“NOT AVAL” (not available) will be displayed when the Channel does not exit.
3. Turn ON/OFF the energy saver outlets on the surge protector
The energy monitor can display the ON/OFF Status of the surge protector. Use the
ON/OFF Key on the energy monitor to turn ON and OFF the energy saver outlets of
the surge protector.
When CH number is changed to ALL, press the ON/OFF key will turn ON/OFF the
control outlets on ALL surge protectors simultaneously.
GREEN POWERLINK Manual All Versions V1.
15
0
18
GREEN POWERLINK Manual All Versions V1.
CO2 Mode
Projected Carbon Emission in KGCarbon Emission per hour in KGHistoric Carbon Emission in KG
Projected Energy Cost in $Energy Cost per hour in $Historic Energy Cost in $
1. View carbon emission per hour for the channel
In CO2 Mode, the energy monitor will first display the carbon emission per hour
for the Channel.
2. View projected carbon emission for the channel
The energy monitor can calculate and display the projected energy cost. Use the
right arrow key to change from carbon emission per hour to projected carbon
emission PER DayƖPER WeekƖPER MonthƖPER Year.
3. View historic carbon emission for the channel
The energy monitor can store and display the historic carbon emission. Use the
right arrow key to change from projected carbon emission to historic carbon
emission LAST DayƖLAST WeekƖLAST MonthƖLAST YearƖTotal (up to date).
Event Mode
In the event of power failure or power overload happening to the energy tracking
surge protector, the energy monitor will alert with beeping and event icon on the
screen. This allows the user to be aware of the unusual power failure conditions of
home electricity.
GREEN POWERLINK Manual All Versions V1.0
Cost Mode
1. View energy cost per hour for the channel
In Cost Mode, the energy monitor will first display the energy cost per hour for the
Channel.
2. View projected energy cost for the channel
The energy monitor can calculate and display the projected energy cost. Use the
right arrow key to change from energy cost per hour to projected energy cost
PER DayƖPER WeekƖPER MonthƖPER Year.
3. View historic energy cost for the channel
The energy monitor can store and display the historic energy cost. Use the
right arrow key to change from projected energy cost to historic energy cost
LAST DayƖLAST WeekƖLAST MonthƖLAST YearƖTotal (up to date).
17
O
a
ua
e
s
o
s
0
O
a
ua
e
s
o
s
0
20
V1.
n
i
r
l All V
n
WERLINK M
View historic events for the channel
1. View what date & time the events occurred
The energy monitor can store and display historic events. In event mode, the event
icon will be flashing and first display FROM what date & time the events occurred.
2. View what date & time the events ended
The energy monitor will then display TO what date & time the events ended.
The above example shows that the event occurred from Feb 6th at 12:06PM and
ended on Feb 6th at 2:03PM.
3. View historic events for the channel in sequence
The number in lower right corner indicates how many times the events happened.
Use the arrow key to change and view events in sequence.
Surge Alert Mode
When energy tracking surge protector encounters surge events, the energy
monitor will alert with beeping and icon on the screen. This allows the user to
be aware of the unusual surge conditions of home electricity.
REEN P
Instant event alert on currently browsing channel
1. When power failure / power overload happens to the currently browsing channel,
the energy monitor will alert with beeping and event icon flashing on the screen.
2. Since the remote surge protector stops working due to power failure / power
overload, NO DATA will be shown on the energy monitor.
Instant event alert insertion from other channels
1. The energy monitor will insert the event alert on the screen and alert with beeping
when event happening to other channels.
2. The event icon and CH number in lower left corner will flash to indicate what CH is
experiencing power failure / power overload conditions.
V1.
n
i
r
l All V
n
WERLINK M
REEN P
19
O
a
ua
e
s
o
s
0
O
a
ua
e
s
o
s
0
22
V1.
n
i
r
l All V
n
WERLINK M
REEN P
2. The icon in the lower right corner will flash and display the intensity of surge
event in minor surge (small icon) or major surge (big icon).
Note:
The instant surge alert insertion will display for short time and return to previous
display mode.
View historic surge events for the channel
Instant surge alert on currently browsing channel
1. When surge events happen to the currently browsing channel, the energy
monitor will alert with beeping and icon flashing on the screen. The energy
monitor will display the surge event frequency in numbers and store the surge
event data for later review.
Note:
The energy tracking surge protector can detect the intensity of the surge
1. View what date and time the surge events occurred
events and display surge alert in minor surge (small icon) or major surge
The energy monitor will first display what date and time the last surge event
(big icon).
occurred. The above example shows that the 5th surge event occurred at 12:00pm
in Nov. 16th.
2. View historic surge events for the channel in sequence
The energy monitor will store and display the surge events frequency in numbers.
Instant surge alert insertion from other channels
Use the arrow key to change and view historic surge events in sequence.
Note:
When viewing historic surge events, the energy monitor will first display minor
surge event data. Press the mode button to go to major surge event page for detail
major surge event information.
V1.
n
i
r
1. When surge event happens to other channel, the energy monitor will alert with
l All V
n
WERLINK M
REEN P
beeping and display what Channel is encountering surge event in lower left corner.
21
0
0
24
REEN POWERLINK Manual All Versions V1.
2. The NO option blinks first. Use the arrow key to select Yes [YS] or NO for event
data delete decision.
Advance Setup Instruction
Delete Surge Event Data Setup
3. Press the SET button to proceed to Delete Surge Event Data Setup page.
In set-up menu, the user can perform the following setup procedures for the
energy monitor.
Press and hold the SET button for 3 seconds to access in the set-up menu. For the
first 5 advance setup options, please refer to Initial Setup Instruction in the
manual.
1. Date & Time Setup
2. Currency Setup
3. Electricity Rate Setup
4. Carbon Emission Setup
1. In Delete Surge Event Data setup page, “DELƖSURGƖDATA” displays in
looping. User may choose to delete all the previous surge event data.
5. Audible Alarm Setup
6. Delete Event Data Setup
7. Delete Surge Event Data Setup
8. Delete History Energy Data Setup
2. The NO option blinks first. Use the arrow key to select Yes [YS] or NO for surge
event data delete decision.
3. Press the SET button to proceed to Delete History Data Setup page.
Delete Event Data Setup
Delete History Data Setup
1. In Delete Event Data setup page, “DELƖEVNTƖDATA” displays in looping. User
may choose to delete all the previous event data.
GREEN POWERLINK Manual All Versions V1.
23
1. Hold the energy monitor close to the energy tracking surge protector.
0
0
2. In the energy monitor channel mode, use the arrow key to select which channel
you wish to add the energy tracking surge protector.
3. On the energy tracking surge protector, press and hold the LEARNING button
for 3 seconds until the green LED indicator light flashes and goes into learning
mode.
Note : you can release the button once the indicator light goes flashing
4. Within 10 seconds, press the LEARNING button on the energy monitor to add
energy tracking surge protector to the selected channel.
5. The Surge Protector will beep once to confirm that it has been successfully
added to the channel on the energy monitor.
6. Redo step 3~5 if learning is not successful.
7. Repeat step 2~5 to add more energy tracking surge protectors to different
26
GREEN POWERLINK Manual All Versions V1.
channels on the energy monitor.
Reset the Energy Monitor to Factory Default
Please follow the instruction below to reset the energy monitor to its factory
default setting.
Note:
By performing resetting energy monitor to factory default, all saved data, setup &
channel settings will be erased.
1. Locate the reset point on top of the energy monitor.
2. Push a stylus or pen into the reset point for 5 seconds.
3. The energy monitor will be hard reset to factory default setting. Please perform
all the necessary setup and channel setting.
GREEN POWERLINK Manual All Versions V1.
1. In Delete History Data setup page, “DELƖHISTƖDATA” displays in looping.
User may choose to delete all the previously saved KWH / COST / CO2 historic
database.
2. The NO option blinks first. Use the arrow key to select Ye s [YS] or NO for
history data delete decision.
3. Press the SET button to proceed to Exit page.
Exit the Setup Page
1. In Exit page, the NO option blinks first. Use the arrow key to select Yes [YS] then
press the SET button to exit the setup menu.
2. Select NO then press SET button will allow the user to re-do setup steps.
Add Channels to the Energy Monitor by Learning
The energy monitor and the energy tracking surge protector in the kit are
pre-paired and ready to use.
You can purchase more compatible energy tracking surge protectors and expand
up to 9 CH by adding to the exiting energy monitor.
25
!
!
!
FEDERAL COMMUNICATIONS COMMISSION
INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
!
This device complies with Part 15 of the FCC Rules. Operation is subject to the
!
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
!
cause undesired operation.
CAUTION:
To assure continued FCC compliance:
Any changes or modifications not expressly approved by the grantee of this device
could void the user's authority to operate the equipment.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.