PowerTech PC170 User Manual

FOR RESIDENTIAL
USER MANUAL
PC170 Control Box
24V DC GEAR MOTOR
INDEX
1. CONTROL BOX
2.1 SW1 DIP SWITCH SETTING
2.1.1 SLOWDOWN ADJUSTMENT (DIP 1. SLOW)
2.1.2 OVER-CURRENT ADJUSTMENT (DIP 2.OVER C1 & DIP 3.OVER C2)
2.1.3 GATE AUTO-CLOSE ADJUSTMENT (DIP 4.AUTO C1, DIP 5.AUTO C2 & DIP 6.AUTO C3)
2.1.4 PEDESTRIAN MODE ADJUSTMENT (DIP 7.P MODE)
2.1.5 FLASHING LIGHT ADJUSTMENT (DIP 8.LIGHT)
2.2 SW2 DIP SWITCH SETTING
2.2.1 PHOTOCELL ADJUSTMENT (DIP 1.PHOTO1, DIP 2.PHOTO2)
2.2.2 CLOSE DELAY OF DUAL GATE OPERATION ADJUSTMENT (DIP 3.DELAY1, DIP 4.DELAY2)
2.2.3 ELECTRIC LATCH ADJUSTMENT (DIP 5.LATCH)
2.2.4 DECELERATION SPEED ADJUSTMENT OF THE GEAR MOTORS (DIP 6. D SPEED)
2.2.5 OPERATION SPEED ADJUSTMENT OF THE GEAR MOTORS (DIP 7. O SPEED)
2.2.6 SINGLE AND DUAL GATE OPERATION ADJUSTMENT (DIP 8.DS/SET)
2.3 LED INDICATION
2.4 TRANSMITTER MEMORIZE
2.5 SYSTEM LEARNING PROCESS
2.6 GATE OPERATION (Optional)
2.7 GATE-MOVING LOGIC
2.8 ADVANCED OPERATION OF THE TRANSMITTER
3. TROUBLE SHOOTING
4. PHOTOCELL INSTALLATION GUIDE
1
3
3
3
3
3
4
4
4
4
5
5
5
5
5
5
6
6
7
7
7
8
9
1. CONTROL BOX
CONTROL BOX INSTALLATION
1. Decide the installation position of control box first, it is suggested to be installed near the gate and should be protected from possible damage. Be aware of the motor cable length before deciding the installation position.
2. Remove the cover by unscrewing the four screws on the cover. See Figure 1(1).
3. Use a screwdriver to puncture the holes beneath the bottom of the control box. See Figure 1(2).
4. Secure it on the wall. See Figure 1(3).
5. Wiring Connection: Prepare all the wires of the accessories beforehand and connect the wires to the gear motors and accessories on the PCB as shown in Figure 1(4). All of the wiring connections of the accessories are not requested to distinguish the positive (+) and the negative (-) polarity.
1). Flashing Light: Connect the two wires from the flashing light to the terminal L+ and L- on the PCB.
2). Electric Latch: Connect the two wires from the electric latch to the terminal Lo + and Lo- on the PCB.
3). Gate openers: Refer to Figure 1(4) and connect the wires separately to the terminals on the PCB. Motor 1: Connect the motor wire (White +) to the terminals Mo1 +, and (Yellow -) to the Mo1-. Motor 2: Connect the motor wire (White +) to the terminals Mo2 +, and (Yellow -) to the Mo2 -.
Notes:
For gates opened outward, Motor 1: Connect the motor wire (Yellow -) to the terminals Mo1 +, and (White +) to the terminals Mo1-. Motor 2: Connect the motor wire (Yellow -) to the terminals Mo2 +, and (White +) to the terminals Mo2 -.
4). Photocells: See Figure 1(4) (A) installed one set Photocell to FO1, SW3 setting as below:
3. Ph_conn1 > OFF and 4. Ph_conn2 > ON
(B) installed one set Photocell to FO2, SW3 setting as below:
3. Ph_conn1 > ON and 4. Ph_conn2 > OFF
(C) installed two sets Photocell, SW3 setting as below:
3. Ph_conn1 > OFF and 4. Ph_conn2 > OFF
(D) No Photocell has been installed, SW3 setting as below:
3. Ph_conn1 > ON and 4. Ph_conn2 > ON
1 2 3 4 5 6 7 8 9
10 11
Transformer
Figure 1(1) Figure 1(2)
Figure 1(3)
CONTROL BOX
1
14 15 16 17
Figure 1(4)
M1 Key Selector Push ButtonLatch
Flashing Light
M2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Transformer
Antenna
LED1
LED2
LED3
LED4
7
6 1 2 3 4108
9 5
CONTROL BOX
2
TX1 TX2 RX1 RX2
2.1 SW1 DIP SWITCH SETTING
2.1.1 SLOWDOWN ADJUSTMENT (DIP 1.SLOW)
2.1.2 OVER-CURRENT ADJUSTMENT (DIP 2.OVER C1 & DIP 3.OVER C2)
Dip Switch 2 OFF
Dip Switch 2 OFF
Dip Switch 2 ON
Dip Switch 2 ON
Dip Switch 3 OFF
Dip Switch 3 ON
Dip Switch 3 OFF
Dip Switch 3 ON
2A
3A
4A
5A
OVER C1 OVER C2 Current (Amp)
2). SETTING
ON: The gear motors do not slow down before the gates completely close or open. OFF: The gear motors slow down before the gates completely close or open.
2.1.3 GATE AUTO-CLOSE ADJUSTMENT (DIP 4.AUTO C1, DIP 5.AUTO C2 & DIP 6.AUTO C3)
Dip switch 4 OFF
Dip switch 4 OFF
Dip switch 4 OFF
Dip switch 4 OFF
Dip switch 4 ON
Dip switch 4 ON
Dip switch 4 ON
Dip switch 4 ON
Dip Switch 5 OFF
Dip Switch 5 OFF
Dip Switch 5 ON
Dip Switch 5 ON
Dip Switch 5 OFF
Dip Switch 5 OFF
Dip Switch 5 ON
Dip Switch 5 ON
Dip Switch 6 OFF
Dip Switch 6 ON
Dip Switch 6 OFF
Dip Switch 6 ON
Dip Switch 6 OFF
Dip Switch 6 ON
Dip Switch 6 OFF
Dip Switch 6 ON
No auto-close
3 sec.
10 sec.
20 sec.
40 sec.
60 sec.
120 sec.
360 sec.
Auto C1 Auto C2 Auto C3 Effect
Note: Auto-close mode activates when the gates move to the end position or stopped manually. If the transmitter, push button, or the key selector is activated before the auto-close counting, the gate will close immediately.
CONTROL BOX
3
Before powering on the control unit, the following dip switch setting must be decided by gate weight and installation environment first. See Figure 2
NC: No Connection
SW1
OFF ON
SW2
OFF ON
SW3
OFF ON
LED1 LED2 LED3 LED4
1. OFF
2. OFF
3. OFF
4. OFF
5. OFF
6. OFF
7. ON
8. OFF
1. Slow
2. Over_C1
3. Over_C2
4. Auto_C1
5. Auto_C2
6. Auto_C3
7. P_Mode
8. Light
1. Photo_1
2. Photo_2
3. Delay_1
4. Delay_2
5. Latch
6. D_speed
7. O_speed
8. D/S_Set
1. Remote_1
2. Remote_2
3. Ph_conn1
4. Ph_conn2
Default Setting
SW1:Set
SW2:Set
SW3:Set
1. ON
2. OFF
3. ON
4. ON
1. OFF
2. OFF
3. OFF
4. OFF
5. ON
6. ON
7. ON
8. ON
2.1.4 PEDESTRIAN MODE ADJUSTMENT (DIP 7.P MODE)
ON: Press button B on the remote to operate to pedestrian mode by open single gate to 45 degree OFF: The pedestrian mode is disabled. Single gate will fully open and close
2.1.5 FLASHING LIGHT ADJUSTMENT (DIP 8.LIGHT)
ON: The flashing light blinks for 3 seconds before the gate moves, and blinks simultaneously during the movement. OFF: The flashing light blinks and the gate moves simultaneously.
1. SW2_2, SW2_1: OFF OFF
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
Safety Device2 :
Photocell-OPEN
Open not allowed
No effect
Open not allowed
No effect
Close
Safety Device1 :
Photocell-CLOSE
No effect
Reload automatic closing time
Reload automatic closing time
Open
No effect
Position of Gate When safety devices are activated
2. SW2_2, SW2_1: OFF ON
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
Safety Device2 :
Safety Edge
Open not allowed
Locks
Reverse to open for 2 seconds
Reverse to clsoe for 2 seconds
Reload automatic closing time
Safety Device1 :
Photocell-CLOSE
No effect
Reload automatic closing time
Open
No effect
Position of Gate When safety devices are activated
3. SW2_2, SW2_1: ON OFF
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
Safety Device2 :
Opening Device
Open
Open
Open
No effect
Reload automatic closing time
Safety Device1 :
Photocell-CLOSE
No effect
Reload automatic closing time
Open
No effect
Position of Gate When safety devices are activated
4. SW2_2, SW2_1: ON ON
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
Safety Device2 :
Photocell-OPEN/CLOSE
Open not allowed
Locks
Stop
Stop
Close not allowed, Open for 2 seconds when auto closing is ON
Safety Device1 :
Photocell-CLOSE
No effect
Close not allowed
Open
No effect
Position of Gate When safety devices are activated
2.2.1 PHOTOCELL ADJUSTMENT (DIP 1.PHOTO1, DIP 2.PHOTO2)
2.2 SW2 DIP SWITCH SETTING
CONTROL BOX
4
2.2.2 CLOSE DELAY OF DUAL GATE OPERATION ADJUSTMENT (DIP 3.DELAY1, DIP 4.DELAY2)
Close/Open delay of two leaves of gate can be adjusted from 2 to 6 seconds
OFF
ON
OFF
ON
Dip3. Delay 1 Dip4. Delay 2
OFF
OFF
ON
ON
2 sec
2 sec
3 sec
3 sec
3 sec
4 sec
5 sec
6 sec
DIP switch
Open Delay Close Delay
2.2.5 OPERATION SPEED ADJUSTMENT OF THE GEAR MOTORS (DIP 7.O SPEED)
ON: The speed is 100% output of the full speed. OFF: The speed is 70% output of the full speed.
2.2.6 SINGLE AND DUAL GATE OPERATION ADJUSTMENT (DIP 8.DS/SET)
ON: Dual Gates operation in system learning and normal operation. OFF: Single Gate operation in system learning and normal operation.
2.2.3 ELECTRIC LATCH ADJUSTMENT (DIP 5.LATCH)
ON: The master leaf will move toward closing direction for 0.25 second once command the remote, then unlock the latch to open the gate. OFF: Once command the remote, the the latch will be unlocked to open the gate immediately
2.2.4 DECELARATION SPEED ADJUSTMENT OF THE GEAR MOTORS (DIP 6. D SPEED)
ON: The speed is 70% output of the full speed. OFF: The speed is 50% output of the full speed.
2.3 LED INDICATION
LED1 System Learning: LED1 is always ON when the system learning in not completed.
LED1 blinks once when single-gate learning is completed ; LED1 blinks twice when dual-gate learning is completed.
LED2 RF : If the switch of the transmitter, key selector, or the push button is activated, LED2 will be on. LED3 Photocells 1 : LED3 will be on when the first pair of the photocells are activated. LED4 Photocells 2 : LED4 will be on when the second pair of the photocells are activated. LED5 RF Indicator : LED5 will be on when RF signal is received.
Antenna
LED1 LED2 LED3 LED4
LED1
LED2
LED3
LED4
SYSlearn
RFLED
Ph01
Ph02
CONTROL BOX
5
CONTROL BOX
6
2.5 SYSTEM LEARNING PROCESS
Press “SYS-learn” button for 2 seconds, after press button (A) on the remote. System learning will be executed step by step as followings: Wait for the learning process to be completed without any interruption.
A. Dual Gate:
Slave Gate Close → Master Gate Close → Master Gate Open → Slave Gate Open → Slave Gate Close → Master Gate Close
B. Single Gate :
Master Gate Close → Master Gate Open → Master Gate Close
1
1
5
2 3
1 2 3
4
6
2 3
1 2 3
4 5 6
! CAUTION: Before proceeding to system learning, the transmitter memorizing process has to be completed.
! Beware: The system learning process for single gate takes more than dual gate for around 1 min, wait for the gate to complete the learning process.
A
B
A
B
2.4 TRANSMITTER MEMORIZING PROCESS
Press “RF-learn” button for 2 seconds, and the Blue LED is on; then press the transmitter (A) button;
the Blue LED will blink twice and then be off. The system learning is complete.
Blue LED blinks twice
Blue LED OFF
Blue LED ON
2 Sec
RF-Learn
2.6 GATE OPERATION
Press the button “A” on the transmitter for dual-gate operation.
Press the button “B” on the transmitter for single-gate operation in either single-gate or dual-gate installation.
2.7 GATE-MOVING LOGIC
(A) In gate-opening phase: The gates stop if the transmitter/push button/key selector is activated, and close when the transmitter/push button/key selector is reactivated. (B) In gate-closing phase: The gates stop if the transmitter/push button/key selector is activated, and open when the transmitter/push button/key selector is reactivated. (C) In gate-opening or gate-closing phase: For safety purpose, the gates stop if encountering obstacles.
2.8 ADVANCED OPERATION OF THE TRANSMITTER (SW3 DIP1/2 REMOTE 1 & REMOTE2)
A.PR-1/PR-2
Situation 1: Dip1. Remote 1:ON & Dip2. Remote 2:ON
Transmitter button A for single leaf operation. Transmitter button B for double leaves operation.
Situation 2: Dip1. Remote 1:ON & Dip2. Remote 2:OFF
Transmitter button B for single leaf operation. Transmitter button A for double leaves operation.
B.PR-2 Extensive (Optional)
Situation 3: Dip1. Remote 1:OFF & Dip2. Remote 2:ON
Transmitter button C for single leaf operation. Transmitter button D for double leaves operation.
Situation 4: Dip1. Remote 1:OFF & Dip2. Remote 2:OFF
Transmitter button D for single leaf operation. Transmitter button C for double leaves operation.
See the following description:
SW3
OFF ON
A
C
D
B
PR-2
CONTROL BOX
7
A
B
Overheated Back-up Batteries The gate doesn’t move when pressing the button of the transmitter
The gate only moves a little distance when pressing the button of the transmitter. The transmitting distance is too short
The gear motors run very slowly The Flashing light does not work The leaves shall be closed instead of opening
The leaves suddenly stop during moving
The leaves does not move or only move toward one direction
The master gate closes to the end first and the slave gate stops, the flashing light blinks fast for five seconds.
The gear motors does not run and the relay is noisy when operating the gate opening and closing
Check the wiring connection of the batteries.
1. Check if LED3 or 4 is “ON”.
2. Check if the voltage of the batteries is below 22V.
3. Check if LED1 is “ON”.
4. Make sure all the wiring connections are firmly connected to the terminals on the PCB.
5. Make sure the fuse is workable. Make sure the wiring connection of the hall sensor is firm.
Make sure the connecting terminals of the Antenna is firm. Check the dip switch setting of the speed adjustment. Check if the wiring connection of the flashing light is correct. Change the polarity connection of the positive (+) with the negative (-) of the gear motors.
1. Check if the “RESET” socket is activated.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the hall sensor wiring connection is firm.
4. The GND terminal of the photocells on the PCB must be short-circuited if no photocells installed.
5. Make sure the fuse is workable.
1. Check if the “RESET” socket is activated.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the hall sensor wiring connection is firm.
4. The GND terminal of the photocells on the PCB must be short-circuited if no photocells installed. Cut off the AC input power and the output of the batteries. Release the master gate and slave gate manually, then open the master to the end and close the slave gate to the end by hand, then power the whole unit by connecting the AC and battery terminals. Check if the fuse is burned.
3. TROUBLE SHOOTING
CONTROL BOX
8
CONTROL BOX
9
The safety photocells are security devices for control automatic gates. Consist of one transmitter and one receiver based in waterproof covers; it is triggered while breaking the path of the beams.
INSTALLATION:
Wire Connection of PH-2 Photocells
TX: Connect terminals 1 and 2 on the transmitter with the terminals G and +12V on the PC170 PCB.
RX: Connect terminals 1, 2 and 4 on the receiver with the terminals G, FO+ and FO1 on the PC170.
And use an extra wire to connect terminals 2 and 5 on the receiver as a bridge.
Detection Method
Sensing Range
Input Voltage
Response Time
Emitting Element
Operation Indicator
Dimensions
Output Method
Current Consumption Max
Water Proof
Through Beam
25M
AC/DC 12~24V
100MS
IR LED
Red LED(RX): ON(When Beam is Broken), Green(TX):ON
96*45*43mm
Relay Output
TX: 35MA/Rx: 38MA (When beam aligned properly);
TX: 35MA/ Rx: 20MA (When beam is broken)
IP54
4. PHOTOCELL INSTALLATION GUIDE
RX
RX
Lens
Beam Alignmnet
Indicator
Power Led
Indicator
Terminal Block
Power
Terminal Block
COM N.C. N.O. GND DC (12~24V)
GND DC (12~24V)
TX
TX
SPECIFICATION:
Figure 4(3)
Figure 4(2)
Figure 4(1)
1 2 3 4 5
1 2 3 4 5 1 2
1 2
34100-093-01-B