MODEL PS-121400FR
12 Volt 140 Amp. Hr.
Sealed Rechargeable
Battery
B
A
T
T
E
R
Y
M
U
S
T
B
E
R
E
C
Y
C
L
E
D
Pb
NONSPILLABLE
MH20845
®
(UL94 V-O flame retardant)
L
HT
H
W
PS-121400FR
12 Volt 140.0 AH
Features
Absorbent Glass Mat (AGM) technology for superior
•
Valve regulated, spill proof construction allows safe
•
Power/volume ratio yielding unrivaled energy density
•
Rugged impact resistant ame retardant ABS case and
•
Integrated ABS carrying handles for ease of movement
•
Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and
•
U.L. recognized under le number MH 20845
•
performance
operation in any position
cover (UL94 V-0)
C.A.B. certi ed
Terminals (mm)
Performance Specifi cations
Nominal Voltage ........................................................................ 12 volts (6 cells)
Nominal Capacity
T11 - THREADED
•
INSERT - 8mm STUD
20-hr. (7A to 10.50 volts) ............................................................. 140.0 AH
10-hr. (13.5A to 10.50 volts) ........................................................ 135.0 AH
5-hr. (24A to 10.20 volts) ........................................................... 120.0 AH
1-hr. (84A to 9.00 volts) ............................................................... 84.0 AH
15-min. (260A to 9.00 volts) ............................................................... 65.0 AH
Physical Dimensions: in (mm)
Approximate Weight ...................................................... 99.00 lbs. (44.91 kg)
Energy Density (20-hr. rate) ................................ 1.71 W-h/in3 (104.48 W-h/l)
Specifi c Energy (20-hr. rate) ............................... 16.97 W-h/lb (37.41 W-h/kg)
Internal Resistance (approx.) ........................................................ 3 milliohms
Max Discharge Current (7 Min.) ............................................. 420.0 amperes
Max Short-Duration Discharge Current (10 Sec.) ................ 950.0 amperes
Shelf Life (% of nominal capacity at 68°F (20°C))
1 Month ...................................................................................................... 97%
3 Months ..................................................................................................... 91%
6 Months .................................................................................................... 83%
Operating Temperature Range
Charge .. ........................................................... -4°F (-20°C) to 122°F (50°C)
L: 13.50 (343) W: 6.73 (171) H: 10.80 (274) HT: 11.15 (283)
Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for
To ensure safe and effi cient operation always refer to the latest edition of our Technical Manual, as published on our website.
All data subject to change without notice.
height dimensions. All data subject to change without notice.
Discharge ....................................................... -40°F (-40°C) to 140°F (60°C)
Case ........................................................ ABS Plastic (UL94 V-O ame retardant)
Power-Sonic Chargers ................................................................................... n/a
www.power-sonic.com

Capacity Retention Ratio (%)
Standing Period (Months)
100
80
60
40
0
0 2 4 6 8 10 12 14 16 18 20
40oC
(104oF)
30oC
(86oF)
20oC
(68oF)
5oC
(41oF)
Chargingis not
necessary unless
100% of capacity
is required.
Chargingbefore
use is necessary
to help recover
full capacity.
Chargemay fail
to restore full
capacity. Do not
let batteries reach
this state.
Constant Power Discharge Ratings
PS-121400FR 12 Volt 140.0 AH
MODEL
PS-121400FR
Discharge Time vs. Discharge Current
20
15
10
h
5
2
1
Discharge Time
30
min
10
5
Final
Voltage
10.5V
FINAL
VOLTAGE
5 MIN 10 MIN 15 MIN 20 MIN 30 MIN 45 MIN 60 MIN
WATTS PER CELL @ 25° C
1.75 680 510 432 366 302 220 176
1.70 720 550 462 376 304 225 180
1.67 740 560 480 381 306 228 182
Discharge Characteristics
14.0
Ambient Temperature 20oC (68oF)
14
28
70
Final
Voltage
140
280
1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 4 0
min
h
Discharge Time
10.2V
9.6V
9.0V
8.1V
40oC (104oF)
20oC (68oF)
0oC (32oF)
13.0
12.0
11.0
10.0
Terminal Voltage (V)
9.0
8.0
7.0
7.0 14 28 70 140 280
Discharge Current (A)
Charging
Cycle Applications: Limit initial current to 20A. Charge until battery voltage
(under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7
volts until current drops to under 1.4A. Battery is fully charged under these
conditions, and charger should be disconnected or switched to “oat” voltage.
“Float” or “Stand-By” Service: Hold battery across constant voltage source of
13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its
own current level and maintain itself in a fully charged condition.
Note: Due to the self-discharge characteristics of this type of battery, it is
imperative that they be charged within 6 months of storage, otherwise permanent
loss of capacity might occur as a result of sulfation.
Chargers
Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH.
Please refer to the Charger Selection Guide in our specication sheets for “C-Series
Switch Mode Chargers” and “Transformer Type A and F Series”. Please contact our
Technical department for advice if you have difculty in locating suitable models.
Contact Information
DOMESTIC SALES
Tel: +1-619-661-2020
Fax: +1-619-661-3650
national-sales@power-sonic.com
© 2011. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.
CORPORATE OFFICE • 7550 Panasonic Way • San Diego, CA 92154 • USA • Tel: +1-619-661-2020 • Fax: +1-619-661-3650
CUSTOMER SERVICE
Tel: +1-619-661-2030
Fax: +1-619-661-3648
customer-service@power-sonic.com
Shelf Life & Storage
Further Information
Please refer to our website www.power-sonic.com for a complete range of useful
downloads, such as product catalogs, material safety data sheets (MSDS), ISO
certication, etc..
www.power-sonic.com
TECHNICAL SUPPORT
Tel: +1-619-661-2020
Fax: +1-619-661-3648
support@power-sonic.com
INTERNATIONAL SALES
Tel: +1-650-364-5001
Fax: +1-650-366-3662
international-sales@power-sonic.com
0211 1M