The main sections of this document are the features and the programming. Descriptions of the individual modules of the
software are available in the help-file under Functions. The header Programming lists the program features in a tabular
format. Interface, documents how to access the ToolMonitor. The respective modules specify the valid transfer parameters
of the functions. This software has been developed by MCD Elektronik GmbH / Germany. For further information how to
use the UI.Drive software, e.g. with the MCD TestManager CE, and for information about MCD Elektronik, please visit
www.mcd-elektronik.de and www.mcd-elektronik.com/kunden/camtec/CAMTEC_USB_Interface.zip
USB2.0 UI.Drive-Interface Technical Data
Supply Voltage +5V provided by USB port from the connected computer
Current Consumption 115mA typical
Insulation USB-Interface to Power Supply Output 3000Vac / 4300Vdc
Insulation USB-Interface to PE 500Vdc
Insulation Power Supply Output to PE 2000Vac / 2900Vdc
AD/DA Converter resolution 12 Bit
AD Converter accuracy ± 0,05% 15ppm/°C
Monitor Output Accuracy ± 0,5% max.
Control Input Accuracy ± 0,8% max.
Data-Flow Control/Monitor 400ms interval, power supply remote on/off occurs immediately
LED Signal
Required Space 22,1 mm (width assembled to power supply unit)
Light = power on
Flash = send/receive data - - - - -
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom
Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
www.powersolve.co.uksales@powersolve.co.uk
p.1/4 12.12A
Technical Features of the Software
Quantity of independent controlled HSEUIreg 10
Control Voltage/Current/Monitoring/Shutdown Yes, manual control and automation via ToolMonitor
Data Logger Yes
Report Files from Data Records Yes, user specific report data configurable
Script Engine COM/DCOM or C# .NET Framework
Visualization Designer Tool Yes, create your customized control windows
COM Server (DCOM, .NET) Yes, to control software via external Software Tools (e.g. MCD
TestManager CE, LabView, Microsoft Excel, Open Office, ...)
Export Log File Data Format HTML, PDF, {mailto:Email}, Printer
User Program Speech Visual Studio, C#, C++, Visual Basic
Characteristics of the Software
The CAMTEC power supply UI.Drive provides a PC interface to CAMTEC programmable power supplies. The power-supply
connection to the PC will be provided via the USB2.0 Interface of CAMTEC. With this software, values for current and
voltage (Ireg, Ureg) can be specified. Furthermore, the actual values of current and voltage (Imon, Umon) can be read. The
actual values can be in graphical, digital or analog form.
The UI.Drive program interface software can be widely adapted and adjusted to the user requirements. Once created
configurations can be saved in project files and be retrieved when needed. In the installation files sample projects are
available in English and German.
Using an integrated scripting engine, all measurements and settings can automatically be performed. In conjunction with
the visualization module for example, signal patterns can be specified. As an example, the power supply drive is
predetermined with a ramp function. (Speech: C# .NET-framework)
With the use of third-party software, the USB power supply control can be remote controlled. For the interface the COM /
DCOM or an .NET assembly is used. This allows for the Tool Monitor to be integrated into a variety of applications (Microsoft
Visual Studio (C #, C + +, Visual Basic), Microsoft Office (e.g. MCD TestManager CE, LabView, Excel, Open Office).
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom
Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
www.powersolve.co.uksales@powersolve.co.uk
p.2/4 12.12A
USB2.0 UI.Drive Interface Hardware incl. UI.Drive
-
Software
304.1093
.001
USB2.0 5
A/B
Data C
able 5m 3520225
Interface Link Cable 12pole to UIreg
306.1066
.001
Minimum System requirements:
- Operating system 32/64bit: Windows Server 2003®, Windows Server 2008®, Windows XP®, Windows 7®
The following steps describe how to install the tool monitor and the USB2.0 UI.Drive-Interface.
Interface Hardware Installation:
Insert the plates into the break-outs on the right side of the HSEUIreg and fix the USB-module with the packed screw.
Note: It is essential to use the delivered M3x8 DIN6900-4Z7 screw with captive washer as it is required to connect the
interface to PE.
Connect to Hardware:
Before installing the UI.Drive-Software it is recommended to connect the USB2.0 UI.Drive Interface to the UIreg Power
Supply.
The USB-Interface analogue I/O works with 0-5V voltage control. Enable the 0-5V position of the UIreg Power Supply
DIP-switch of both the control and the monitor signal. If the 0-10V control position is enabled the UIreg will supply only
50% of its maximum voltage.
The USB2.0 UI.Drive-Interface hardware shows two connections. Use the equipped 12-pin connector with the UI.Drivecable to connect the interface to your CAMTEC HSEUIreg Power Supply. Plug the 5m B/A-USB cable into the interface
and then into a free USB port of your Computer. The USB2.0 UI.Drive-Interface is powered by the USB-port of the
Computer. The power LED of the interface will stay dark. Follow below install instructions for the UI.Drive Software.
OrderingInformation:
Software Installation:
Installing the UI.Drive software requires up to date Microsoft™ Windows® Install Manager. Make sure that .NETFramework 3.5 or higher is pre installed. Plug the delivered USB-Stick into the Computer. Access the provided
installation program and follow the displayed instructions. Before installing an update of the UI.Drive-Software, please
remove any previously existing version.
Software License:
Protecting the UI.Drive-Software from unauthorized use it is necessary (for some tool monitors), to register license after
installation. A detailed description of registering is given at the end of this document. For testing purposes, the tool
monitor can be operated for 30 minutes without a license. A limited license of eight hours can be registered, as well.
However some program features are being disabled.
Deinstallation:
To deinstall the UI.Drive software use Windows™ Install Manager: Windows-> Control Panel-> Programs and Features
Ordering Information
Type Camtec Part No.
Spare Parts Camtec Part No.
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom
Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
p.3/4 12.12A
www.powersolve.co.uksales@powersolve.co.uk
Mechanical Drawing USB2.0 Interface:
A = analogue I/O connector
B = USB2.0 connector
Purchased Package Content:
♦ 1x USB2.0 Interface Hardware Module
♦ 1x UI.Drive Software License on USB2.0-Stick
♦ 1x USB2.0 Cable 5m Type A/B (Art.No. 3520225)
♦ 1x Interface Link Cable 12p. (Art.No. 306.1066.001)
♦ 1x Mounting Screw DIN6900-4Z7 Pozidriv-Z M3x8mm (PE connection!)
♦ 1x Short Manual
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom
Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)