Powersolve TEL30 User Manual

DC-DC Converters
TEL 30 Series, 30 Watt
Features
50.8 x 25.4 x 10.2 mm Metal package
Wide 2 : 1 input range
Operating temperature range -40°C to +70°C
Short circuit protection
Adjustable output voltage
Industry standard pin outs
Electrical Specification
Output Voltage Adjustment ±10% by external resistor Input filter Pi-filter Short Circuit Protection continuous, automatic recovery Operating Temperature Range -40°C to +70°C (derate at 2%/°C above 50°C) I/O Isolation test voltage 1500VDC Safety Approvals cUL/UL 60950-1, IEC/EN 60950-1, CB Casing metal, 6-side shielded with insulated baseplate
www.powersolve.co.uk
Output Voltage and Current Ratings
MODEL INPUT OUTPUT OUTPUT  RIPPLE & LINE LOAD EFF.
TEL 30-2409 2.5VDC 6000mA 100mV pk-pk max. 0.3% 1.0% 84% TEL 30-2410 3.3VDC 6000mA 100mV pk-pk max. 0.3% 1.0% 86% TEL 30-2411 18 - 36V 5.1VDC 5000mA 100mV pk-pk max. 0.3% 1.0% 84% TEL 30-2412 12VDC 2500mA 100mV pk-pk max. 0.3% 1.0% 88% TEL 30-2413 15VDC 2000mA 100mV pk-pk max. 0.3% 1.0% 88% TEL 30-4809 2.5VDC 6000mA 100mV pk-pk max. 0.3% 1.0% 84% TEL 30-4810 3.3VDC 6000mA 100mV pk-pk max. 0.3% 1.0% 86% TEL 30-4811 36 - 75V 5.1VDC 5000mA 100mV pk-pk max. 0.3% 1.0% 84% TEL 30-4812 12VDC 2500mA 100mV pk-pk max. 0.3% 1.0% 88% TEL 30-4813 15VDC 2000mA 100mV pk-pk max. 0.3% 1.0% 88%
VOLTAGE VOLTAGE CURRENT NOISE REG. REG.
Mechanical and Connection Details
Pin Single Output
1 +Vin (Vcc) 2 -Vin (GND) 3 No Pin (or optional Remote On/Off) 4 +Vout 5 -Vout 6 Trim
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk
Loading...