AC-DC Converter
CFM60T Series 60 Watt Open Frame Triple Output
Features
Universal input range 90-264Vac
Industry standard pin outs
Efficiency to 83%
Meets CISPR/FCC Class B, conducted
Continuous short circuit protection
Electrical Specification
INPUT
Input Voltage Range 90 - 264Vac Frequency 47 - 63Hz Inrush Current 50A max. @ 240Vac
Cold start @ 25°C Conducted EMI CISPR/FCC Class B Isolation - Input/Output 4242VDC Leakage Current 3.5mA max.
OUTPUT
Hold-up Time 8mS typ. @ 115Vac Short Circuit Protection Continuous Temperature Coefficient ±0.05% / °C Over voltage Protection Auto recovery
www.powersolve.co.uk
ENVIRONMENTAL
Operating Temperature Range 0°C to 50°C Storage Temperature Range -20°C to +85°C Cooling Natural convection Safety Approvals cUL/UL 60950, TUV EN60950
GENERAL
Dimensions 101.6 x 50.8 x 32.0 mm
4.0 x 2.0 x 1.26 inches
Weight 170g
Output Voltage and Current Ratings
MODEL OUTPUT OUTPUT CURRENT RIPPLE VOLTAGE LINE LOAD OUTPUT % EFF.
CFM60T-01 V2 = 12V 0A 3.0A 3.7A 120mV ±5% ±1% ±3% 62W 83%
CFM60T-02 V2 = 15V 0A 2.5A 3.1A 150mV ±4% ±1% ±3% 62W 83%
CFM60T-03 V2 = 24V 0A 1.5A 1.8A 240mV ±3% ±1% ±3% 62W 83%
CFM60T-04 V2 = 5V 0A 3.0A 3.7A 50mV ±5% ±1% ±4% 40.8W 78%
NOTE:
1. Voltage accuracy is measured at 60% rated load.
2. Output noise and ripple measured with 10µF tantalum & 0.1µF ceramic capacitors across output.
3. Line regulation is measured from 103Vac - 127Vac & 207Vac - 253Vac at rated load.
4. Load regulation is defined by changing Output1 load from 20-100% of rated with other loads at 60% of rated.
Typical at 25°C, nominal line and 75% load unless otherwise stated.
VOLTAGE Min. Rated Max. (mV pk-pk) ACCURACY REG. REG. POWER max.
V1 = 5V 0A 4.0A 5.0A 50mV ±2% ±1% ±4%
V3 = -12V 0A 0.5A 0.65A 120mV ±5% ±1% ±5%
V1 = 5V 0A 4.0A 5.0A 50mV ±2% ±1% ±4%
V3 = -15V 0A 0.3A 0.5A 150mV ±5% ±1% ±5%
V1 = 5V 0A 4.0A 5.0A 50mV ±2% ±1% ±4%
V3 = -12V 0A 0.5A 0.6A 120mV ±5% ±1% ±5% V1 = 3.3V 0A 6.0A 7.5A 50mV ±4% ±1% ±5%
V3 = -12V 0A 0.5A 0.65A 120mV ±5% ±2% ±5%
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk
Page 2
AC-DC Converter
Derating Curve
www.powersolve.co.uk
Mechanical and Connection Details
All dimensions in inches (mm) Tolerances: Inches x.xxx ±0.02
Millimeters x.xx ±0.5
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk