AC-DC Converter
CFM101S Series
100 Watt Open Frame
Single Output
Features
• Universal input range 90-264Vac
• Active PFC Function
• 2” x 4” (50.8 x 101.6mm) size
• Efficiency to 85%
• Continuous short circuit protection
• Meets CISPR/FCC Class B, conducted
Electrical Specification
INPUT
Input Voltage Range 90 - 264VAC
Frequency 47 - 63Hz
Inrush Current 90A max. @ 240VAC
Conducted EMI CISPR/FCC Class B
Isolation - Input/Output 4242VDC
Leakage Current 3.5mA max.
www.powersolve.co.uk
OUTPUT
Hold-up Time 18mS typ. @ 115Vac
Short Circuit Protection Continuous
Temperature Coefficient ±0.05% / °C
ENVIRONMENTAL
Operating Temperature Range 0°C to +40°C
Storage Temperature Range -20°C to +85°C
Cooling Natural convection
Safety Approvals cUL/UL 60950, TUV EN60950
GENERAL
Dimensions 101.6 x 50.8 x 27.94 mm
Weight 150g
4.0 x 2.0 x 1.1 inches
Output Voltage and Current Ratings
MODEL OUTPUT OUTPUT CURRENT RIPPLE VOLTAGE LINE LOAD
CFM101S120 12V 0A 8.4A 1% ±1% ±0.5% ±1%
CFM101S150 15V 0A 6.7A 1% ±1% ±0.5% ±1%
CFM101S240 24V 0A 4.2A 1% ±1% ±0.5% ±1%
CFM101S480 48V 0A 2.1A 1% ±1% ±0.5% ±1%
NOTE:
1. Output noise and ripple measured with 10µF electrolytic & 0.1µF ceramic capacitors across output.
2. Line regulation is measured from 100Vac to 240Vac at full load.
3. Load regulation is measured from 10-100% of full load.
VOLTAGE Min. Max. (mV pk-pk) ACCURACY REG. REG.
Typical at 25°C, nominal line and 75% load unless otherwise stated.
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk

AC-DC Converter
Mechanical and Connection Details
www.powersolve.co.uk
All dimensions in inches (mm)
Tolerances: Inches x.xxx ±0.02
Millimeters x.xx ±0.5
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk