Powersolve 1200S User Manual

el: +44 (0) 1635 521858
Unit 8A Arnhem Road Newbury. RG14 5RU
T
Fax: +44 (0) 1635 523771 www.powersolve.co.uk
1200 S - Se ries 1200 W SWITCHED MODE DC POWER SUP PLY
Mod els Volt age Cur rent
1200 S 24 12 -15 V 60 A
24 V 50 A
30 V 40 A
Mod els Volt age Cur rent
1200 S 48 24 -30 V 30 A
48 V 25 A
60 V 20 A
Very high re li abil ity, MTBF 500.000 hrs • No RFI prob lems, RFI fil ters in out put and in put
Natural convection cooling Build-in diode for redundant parallel operating
High efficiency 89% Analog programmable
Under-voltage alarm contact • Short circuit protected
Low output ripple, 7 mV rms • Low inrush current
Spec i fi ca tions :
Input voltage : AC 198-264 V 48-62 Hz 8.2 Arms Output voltage : Screwdriver adjustable with 10 fuse 15 A T, crest factor 2.2 turn potmeter at the rear side. : AC 99-132 V 48-62 Hz 16.4 Arms Also programmable by 2-5 V fuse 25 A T Efficiency : 89% at 230 V AC input. : DC contact factory • Temp. coeff. : 5.10-5 per C
Insulation Stability : 3.10-4 during 8 hrs under
Input / output : 3750 V rms (1min) constant conditions, after 1 hr Input / case : 2500 V rms (1min) warm up.
Output / case : 500 V DC Regulation
Inrush current : Limited by 39 Ohm (shorted after startup) Load 0 - 100% : Better than 10 mV
Line disortion : Kept low by large low frequency choke input Line 198 -264 V : Better than 5 mV
Power factor : 0.72 at 230 V AC input and full load. • Ripple + noise (BW = 20 MHz) : Max. 7 mV rms, 20 mV pp
Safety : EN 60950 / EN 61010 • Output imp. : Less than 0.05 Ohm up
SELV / PELV ( for 1200 S 24 only ) to100kHz
EMC : EN 61204-3 Power Supply Standard Recovery time : 0.3 milliseconds to recover within : EN 61000-6-3 Emission (EN 55022B) 100 mV after 50 to 100% load : EN 61000-6-2 Immunity step. Max deviation 300 mV.
Hold-up time : 15 ms at 115 or 230 V AC input
VDE0160 impulse test : Input with stands non periodic impulse and full load. 30 ms at half load.
2.3 Ûn 0.3 ms of VDE0160 class 1 Series operation : Up to 500 V total Voltage.
Redundant parallel Use R+ connection via build-in
Parallel operation : For safe parallel operation put current operation Schottky diode to separate the
limit switch at 'LO' ( max.1100 W) outputs. put current limit at 'LO'
Do not use remote sensing.
1200 S 24
Under voltage alarm contact : changes over when output voltage drops Overload Protection : Continuous overload and short circuit to 10% below the set value. Contact rating does not harm the unit. At short circuit 100 mA / 30 V. the power supply produces an audible
Remote control : Is possible with a 10 KΩ potmeter. bleep.
Remote programming : Output voltage is programmable with 2-5 V, Voltage limit : For safety an extra regulation circuit limits
corresponding with 12-30 V (24-60 V). the output voltage to about 31 V (62 V) in Programming speed is 100 ms from 12-30 V in case of malfunction of the normal (24-60 V) at max. current. Programming input regulation. This limit is internally adjustable is not isolated ( connected to - output) 20-31 V (40-62 V) (R111).
Remote sensing : max. 3 V per load lead. however the sum of Led lamps : Green leds on the front and rear panel voltage across load + leads cannot exceed indicate output voltage. 30 V (60 V) With parallel operation remote Wall mounting : The natural convection cooling functions sensing is not recommended. best when the unit is mounted vertically
Remote on/off : By 5 V, optocoupler isolated. as drawn ( input at upper side )
Ambient temperature The covers are used as heat sinks, so
Storage : - 40 to + 85 C some space between cover and wall is Operating : - 20 to + 50 C mounted vertically necessary.
: - 20 to + 40 C mounted horizontally
Temperature derating
Current limit : Can be put on HI or LO with a switch on 19 " rack adapter : Although vertical mounting is preferred the front panel. for optimal cooling, the unit can also be From 30 V to 18 V (60 to 36 V) the current mounted horizontally in a 19" rack (2 U) limit follows more or less a constant power The current limit switch has to be put on curve. below 18 V (36 V) it resembles a 'LO' (max. 1100W). when forced air constant current curve. cooling is used, the full 1200 W can be
Dim and weight : Height : 88 mm
Current limit 1200 S 24
Two ways of vertical mounting
be taken continuously (limit on 'HI').
: Width : 433 mm : Depth : 385 mm : Weight : 11 kg
Bracket H88 for vertical wall
mounting (2 pcs required)
Cover of connection panel
Page 2 SPECIFICATIONS Rev. Sept. 2012
Bracket H114 for vertical
wall mounting.
( 4 pcs required )
Bracket H88 with handle for
19" rack mounting
(2 pcs required)