Refer to the illustration below for the location of Serial Number. Record generator information in the
spaces provided below.
DATE OF PURCHASE: ______________________________________________
PURCHASED FROM: ______________________________________________
GENERATOR MODEL NUMBER: ____________________________________
ENGINE SERIAL NUMBER: _________________________________________
This manual provides information regarding the safe operation and maintenance of this product.
Every effort has been made to ensure the accuracy of the information in this manual. Powerpro
Technology
notice.
Please keep this manual available to all users during the entire life of the generator.
TM
reserves the right to change this product and specifications at any time without prior
TM
Product.
Special Messages
This manual contains special messages to bring attention to potential safety concerns, generator
damage as well as helpful operating and servicing information. Please read all the information
carefully to avoid injury and machine damage.
Questions? Problems?
DO NOT RETURN TO STORE
Store personnel where the generator was purchased are not trained to handle technical
questions or problems.
In order to answer questions and solve problems in the most efficient and speedy manner,
contact Customer Service at:
(800) 232-1195 M-F 8-5 CST
NOTICE REGARDING EMISSIONS
Engines that are certified to comply with U.S. EPA emission regulations for SORE (Small Off
Road Equipment), are certified to operate on regular unleaded gasoline, and may include the
following emission control systems: (EM) Engine Modifications and (TWC) Three-Way Catalyst
(if so equipped).
1
SAFETY INFORMATION
Before operating this generator read and observe all warnings, cautions, and instructions on
this sheet, on the generator, and in the Owner’s Manual.
NOTE: The following safety information is not meant to cover all possible conditions and
situations that may occur. Read the entire Owner’s Manual for safety and operating
instructions. Failure to follow instructions and safety information could result in serious
injury or death.
This safety alert symbol is used to identify safety information about hazards that can result in
personal injury.
A signal word (DANGER, WARNING, or CAUTION) is used
with the alert symbol to indicate the likelihood and the potential severity of injury.
In addition, a hazard symbol may be used to represent the type of hazard.
DANGER indicates a hazard, which, if not avoided, will result in death or serious
injury.
WARNING indicates a hazard, which, if not avoided, could result in death or
serious injury.
CAUTION indicates a hazard, which, if not avoided, might result in minor or
moderate injury.
CAUTION, when used without the alert symbol, indicates a situation that could
result in damage to the engine or generator.
SAFETY SYMBOLS AND MEANINGS
2
GENERAL SAFETY PROCEDURES
For any questions regarding the hazard and safety notices listed in this manual or on the
product, please call (800) 232-1195M-F 8-5 CST before using the generator.
DANGER: CARBON MONOXIDE. Using a generator indoors CAN KILL
YOU IN MINUTES.
Generator exhaust contains carbon monoxide (CO). This is a poison gas you
cannot see or smell. If you can smell the generator exhaust, you are breathing CO.
But even if you cannot smell the exhaust, you could be breathing CO.
• NEVER use a generator inside homes, garages, crawlspaces, or other partly enclosed
areas. Deadly levels of carbon monoxide can build up in these areas. Using a fan or
opening windows and doors does NOT supply enough fresh air.
• ONLY use a generator outside and far away from windows, doors, and vents. These
openings can pull in generator exhaust.
Even if you use a generator correctly, CO may leak into the home. ALWAYS use a batterypowered or battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh
air RIGHT AWAY. See a doctor. You may have carbon monoxide poisoning.
WARNING: The exhaust from this product contains chemicals known to the
State of California to cause cancer, birth defects, or other reproductive harm.
WARNING: This generator may emit highly
flammable and explosive gasoline vapors, which can
cause severe burns or even death, if ignited. A nearby open flame can lead to
explosion even if not directly in contact with gasoline.
• Do not operate near open flame.
• Do not smoke near generator.
• Always operate on a firm, level surface.
• Always turn generator off before refueling. Allow generator to cool for at least 2
minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.
• Do not overfill fuel tank. Gasoline may expand during operation. Do not fill to the
top of the tank. Allow for expansion.
• Always check for spilled fuel before operating.
• Empty fuel tank before storing or transporting the generator.
• Before transporting, turn fuel valve to off and disconnect spark plug wire.
3
WARNING: This generator produces powerful voltage, which can
result in electrocution.
• ALWAYS ground the generator before using it (see the “Ground the Generator”
portion of the “GENERATOR PREPARATION” section).
• Generator should only be plugged into electrical devices, either directly or with an
extension cord. NEVER connect to a building electrical system without a qualified
electrician. Such connections must comply with local electrical laws and codes.
Failure to comply can create a back-feed, which may result in serious injury or death
to utility workers.
• Use a ground fault circuit interrupter (GFCI) in highly conductive areas such as
metal decking or steel work. GFCIs are available in-line with some extension cords.
• Do not use in rainy conditions.
• Do not touch bare wires or receptacles (outlets).
• Do not allow children or non-qualified persons to operate.
WARNING: This generator produces heat when running. Temperatures
near exhaust can exceed150º F (65º C).
• Do not touch hot surfaces. Pay attention to warning labels on the generator identifying
hot parts of the machine.
• Allow generator to cool down after use before touching engine or areas of the generator
that become hot during use.
CAUTION: Misuse of this generator can damage it or shorten its life.
• Use generator only for its intended purposes.
• Operate only on dry, level surfaces.
• Allow generator to run for several minutes before connecting electrical devices.
• Shut off and disconnect any malfunctioning devices from generator.
• Do not exceed the wattage capacity of the generator by plugging in more electrical devices
than the unit can handle.
• Do not turn on electrical devices until after they are connected to the generator.
• Turn off all connected electrical devices before stopping the generator.
• Turn the engine switch to “OFF” position when the engine is not running.
4
IMPORTANT SAFETY INSTRUCTIONS
•SAVE THESE INSTRUCTIONS – This manual contains important instructions for
Powerpro Technology 8750E generator that should be followed during installation and
maintenance of the generator and battery.
• Generators vibrate in normal use. During and after the use of the generator, inspect the
generator as well as extension and power supply cords connected to it for damage resulting
from vibration. Have damaged items repaired or replaced as necessary. Do not use plugs or
cords that show signs of damage such as broken or cracked insulation or damaged blades.
• For power outages, permanently installed stationary generators are better suited for
providing backup power to the home. Even a properly connected portable generator can
become overloaded. This may result in overheating or stressing the generator components,
possibly leading to a generator failure.
•WARNING: When this generator is used to supply a building wiring system:
Generator must be installed by a qualified electrician and connected to a transfer switch as
a separately derived system in accordance with the National Electrical Code,NFPA 70.
The generator shall be connected to a transfer switch that switches all conductors other than
the equipment grounding conductor. The frame of the generator shall be connected to an
approved grounding electrode.
5
In addition to the previous safety notices, please become familiar with the safety and hazard
markings on the generator.
DANGER
6
PACKAGE CONTENTS
Your generator comes with the items listed below. Please check to see that all of the following
items are included with your generator.
If there are any damaged or missing items, please call (800) 232-1195M-F 8-5 CST for
customer service. DO NOT RETURN TO STORE. Store personnel are not trained to assist
with damaged or missing items.
ITEM LIST
NEMA L14-30 locking plug for 120/240 Volt devices
NEMA L5-30 locking plug for 120V devices
Spark plug wrench
Mobility kit
Wrenches
7
GENERATOR COMPONENTS
Please familiarize yourself with the locations and functions of the various components and controls
of your generator.
9
(1) Air Cleaner- A removable, cleanable, sponge-
like element that limits the amount of dirt pulled
into the engine.
(2) Fuel Valve- Allows fuel to enter engine.
(3) Fuel Filter Cup- Traps dirt and water from fuel
before it enters the engine.
(4) Recoil Starter- Pull-cord for starting engine.
(5) Electric start Switch- To start/stop engine.
(6) Oil Fill and Dipstick- Location for checking and
filling engine oil.
(7) Circuit Reset Buttons- Reset buttons that protect
the generator from electrical overload.
(8) 120Volt AC Duplex Receptacles- To connect
electrical devices that run 120 Volt, 60 Hz, single
phase, AC current.
(9) 120Volt AC Twist Lock Receptacle- To connect
electrical devices that run 120 Volt, 60 Hz, single
phase, AC current.
8
(10) Ground Terminal- Connect grounding wires he re
to properly ground unit.
(11) 120/240 Volt AC Receptacle- To connect electrical
devices that run 120 and/or 240 Volt, 60 Hz, single
phase, AC current.
(12) Digital Engine Hour Meter-Tracks hours of
operation.
(13) Fuel Gauge- Indicates the amount of fuel in the
tank.
(14) Fuel Cap- Access to the fuel tank for adding fuel
(15) Choke Lever- Adjusts the amount of air let into the
1. Blocking up the muffler side of the generator, assemble the axle to the frame.
2. Slide the wheel and washer onto the axle, with the offset of the wheel hub against the frame.
3. Secure the wheel to the axle with the cotter pin.
4. Repeat above instructions for the remaining wheel.
Step 2 –Foot Installation
1. Blocking up the engine side of the generator, assemble the rubber foot to the frame.
2. Repeat above instructions for the remaining foot.
Step 3 –Handle Installation
1. Assemble the handle to the frame (align with hole in tubing). Slide the bolt through handle,
frame and washer and secure with the nut. Tighten until handle is securely clamped to the
frame.
2. Repeat above instruction for remaining handle.
GENERATOR PREPARATION
Using the Generator for the First Time
The following section describes steps necessary to prepare the generator for use. If after
reading this section, you are unsure about how to perform any of the steps please call
232-1195M-F 8-5 CST
damage the generator or shorten its life.
for customer service. Failure to perform these steps properly can
(800)
Step 1 - Fill Oil
The generator is shipped without oil. User must add the proper amount of oil before operating the
generator for the first time. The oil capacity of the engine crankcase is 37 fluid oz.
Select good quality detergent oil bearing the American Petroleum Institute (API) service
classifications SJ, SL, or SM. (Synthetic oils may be used.) Use the SAE viscosity grade
9