Powerplus POWXG9540 User guide

Page 1
POWXG9540 EN
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 SYMBOLS ........................................................................................ 2
5 GENERAL POWER TOOL SAFETY WARNINGS .......................... 3
6 BEFORE START-UP, NOTE THE FOLLOWING! ........................... 3
7 INSTALLATION ................................................................................ 3
8 MAINS SUPPLY ............................................................................... 4
9 COMMISSIONING ............................................................................ 4
13 ANOMALIES – SOURCES – REMEDIES ....................................... 5
14 TECHNICAL DATA .......................................................................... 6
15 SERVICE DEPARTMENT ................................................................ 6
16 STORAGE ........................................................................................ 6
18 ENVIRONMENT ............................................................................... 7
Copyright © 2022 VARO NV
P a g e | 1 www.varo.com
Page 2
POWXG9540 EN
Denotes risk of personal injury or damage to the tool.
Read manual before use
MULTI-STAGE SUBMERSIBLE PUMP 750W POWXG9540
1 APPLICATION
This pump is used primarily as cellar pump. When installed in a shaft, the pump provides protection from flooding. It is also used wherever water has to be moved from one place to another, e.g. in the home, agriculture, horticulture, plumbing and many other applications. Not suitable for professional use.
WARNING! Read this manual and general safety instructions carefully before using the appliance, for your own safety. Your power tool should only be passed on together with these instructions.
2 DESCRIPTION (FIG A)
1. motor housing
2. water inlet
3. water outlet
4. cable & plug
5. floating switch
6. carrying handle
3 PACKAGE CONTENT LIST
Remove all packing materials Remove remaining packaging and transit supports (if existing) Check the completeness of the packing content Check the appliance, the power cord, the power plug and all accessories for transportation
damages.
Keep the packaging materials as far as possible till the end of the warranty period.
Dispose it into your local waste disposal system afterwards.
WARNING Packing materials are no toys! Children must not play with plastic bags! Danger of suffocation!
1x pump 1x Manual 1x connector
When parts are missing or damaged, please contact your dealer.
4 SYMBOLS
In this manual and/or on the machine the following symbols are used:
Copyright © 2022 VARO NV
P a g e | 2 www.varo.com
Page 3
POWXG9540 EN
5 GENERAL POWER TOOL SAFETY WARNINGS
Read all safety warnings and all instructions. Failure to follow all warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference. The term "power tool" in the warnings refers to your mains operated (corded) power tool or battery operated (cordless) power tool.
6 BEFORE START-UP, NOTE THE FOLLOWING!
The pump can be connected to any shock-proof plug which has been installed according
to regulations. The plug must have a supply voltage of 230 V ~ 50 Hz. Fuse min. 6 Amp.
Caution!
When the pump is to be used near swimming pools or garden ponds and in their area of protection, it must be equipped with a PRCD (residual current circuit breaker) with a nominal trip current of max. 30 mA (according to VDE 0100, part 702 and 738). The pump must not be operated while people are in the swimming pool or in the garden pond! Please contact your electrician!
Attention!
(Important for your own security) Before starting to run your new submersible pump, please have the following items checked by an expert:
Ground connection Zero conductor Fault current breaker switch must correspond the safety regulations of the power plants
and they must work faultlessly.
The electrical connections must be protected from moisture. If there is danger of flooding, the electrical connections must be taken to higher ground. Circulation of aggressive fluids, as well as the circulation of abrasive materials must be
avoided at all costs.
The submersible motor-driven pump must be protected from frost. The pump must be protected from running dry. Access on the part of children should also be prevented with appropriate measures.
Consistency
Your submersible pump is designed for the circulation of water with a maximum temperature of 35° C. This pump may not be used for other fluids, especially motor fuels, cleaning fluids, and other chemical products!
7 INSTALLATION
This pump is designed for exclusively domestic installation:
In places where there is a risk of flooding. In sumps or wells.
Keep an empty space around the pump so that the float switch can work without being blocked (e.g. use a sump at least 40x40x50 cm). The pump is designed to run in liquid not exceeding 35 °C. It can be installed:
With either a fixed conduit. Or a flexible conduit.
It must be fixed by the handle provided for the purpose or set at the bottom of the sump (it must be clean with no impurities or sludge) If water level is low (long period of drought), be careful to ensure that any impurities or sludge, after drying, do not prevent the pump from starting up. Consequently, you must make sure that the site where the pump is installed is clean and run the pump from time to time. The pump must always be used in the upright position (the handle on top), it is recommended to secure the pump by attaching a rope (or similar item) to the handle and the other end to an easy accessible static object.
Copyright © 2022 VARO NV
P a g e | 3 www.varo.com
Page 4
POWXG9540 EN
8 MAINS SUPPLY
Before starting up the pump make sure that: The pump is to be powered by a residual differential current device, with a rated operating
differential current not exceeding 30 mA.
The mains supply voltage matches the voltage indicated on the pump identification plate
(230v~/50Hz). Ask your specialist electrician for advice. Make sure that the fuse protecting the power outlet is at least 6 amps.
Warning! If the power cable is damaged, it must be replaced by a professional to avoid the risk of danger.
9 COMMISSIONING
After installing the pump as indicated in these instructions, it is ready to work.
10 SERVICING!
Disconnect the power outlet before making any adjustments or performing servicing
operations. The pump does not require any specific maintenance but for longer life we recommend
that you check and clean the area in which the pump is installed (every three months, for
example). For temporary use, clean the pump with clean water after using it.
11 CLEANING THE TURBINE
Remove the plug from the power outlet before cleaning operations start
If there are heavy deposits in the pump body, the lower part must be dismantled as follows:
Remove the 7 screws from the lower side of the suction basket. Detach the suction basket from the body of the pump. Clean the pump with clean water.
Warning! Do not put down the pump on the turbine nor hold it by this point either!
For reassembly, repeat the above operations in reverse order.
12 SETTING THE SWITCH POINT
The float switch point can be set by adjusting the notches. Check the following points before switching on: The float switch must be installed so that the switch point level can be reached easily with
very little effort. Make sure of this as follows: immerse the pump in a container full of water
and lift the float switch carefully by hand, then lower it. You can thereby check that the
pump starts and stops. Make sure that the gap between the head of the float switch and the float switch
anchorage device is not too small. If the gap is not wide enough, perfect operation is not
guaranteed. Concerning adjustment, make sure that the float switch does not touch the floor before the
pump has stopped. Warning! Risk of running dry. To modify the starting level, slide the float cable into the notch provided for the purpose on
the handle.
Copyright © 2022 VARO NV
P a g e | 4 www.varo.com
Page 5
POWXG9540 EN
Anomalies
Sources
Remedies
The pump won't start
Power not switched on The float switch is not
connected to the circuit
Check the mains voltage Lift the float
The pump won't discharge
The intake filter is
clogged
The discharge pipe is
stuck
Clean the intake filter
with a water jet
Release the pipe
The pump won't stop
The float switch is
blocked in the upper part
Release the float and
reposition the pump
The flow rate is inadequate
The intake filter is
clogged
Pumping flow rate falls
because the pump is clogged with water impurities
Clean the filter
Clean the pump and its
environment
The pump stops after working for a short time
The motor protection
device stops the pump because the water is too dirty.
The water is too hot, the
heat protector stops the pump.
Pull out the plug and
clean the pump and sump
Make sure the water
temperature does not exceed 35ºC!
13 ANOMALIES – SOURCES – REMEDIES
Copyright © 2022 VARO NV
P a g e | 5 www.varo.com
Page 6
POWXG9540 EN
Rated Voltage AC min (Un)
230V~
Rated frequency
50Hz
Rated power (Pn) min:
750W
Rated pressure
2.2bar
Cable length
10m
Max flow rate
3200l/h
Max water temperature
35°C
Max grain size
2mm
Submersible depth
7m
Residual water height
5mm
Max pressure height
22m
Water type
clean water
Pump type
submersible
Pump house material
PP
Material housing
PP
Motor winding material
aluminum
Impeller
3pieces
Self-venting
Yes
Self-priming
Yes
Automatic switch
Yes
Run dry protection
Yes
Overload protection
Yes
14 TECHNICAL DATA
15 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department. If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).
16 STORAGE
Thoroughly clean the whole machine and its accessories. Store it out of the reach of children, in a stable and secure position, in a cool and dry
place, avoid too high and too low temperatures.
Protect it from exposure to direct sunlight. Keep it in the dark, if possible. Don’t keep it in plastic bags to avoid humidity build-up.
Copyright © 2022 VARO NV
P a g e | 6 www.varo.com
Page 7
POWXG9540 EN
17 WARRANTY
This product is warranted as provided by law for a 36-month period effective from the date
of purchase by the first user. This warranty covers all material or production flaws. It does not include defective parts
subject to normal wear & tear such as bearings, brushes, cables, and plugs, or
accessories such as drills, drill bits, saw blades, etc. ; damage or defects resulting from
maltreatment, accidents or alterations; nor the cost of transportation. Damage and/or defects resulting from inappropriate use also do not fall under the
warranty provisions. We also disclaim all liability for any bodily injury resulting from inappropriate use of the
tool. Repairs may only be carried out by an authorised customer service centre for Powerplus
tools.
You can always obtain more information at the number 00 32 3 292 92 90. Any transportation costs shall always be borne by the customer, unless agreed otherwise
in writing. At the same time, no claim can be made on the warranty if the damage of the device is the
result of negligent maintenance or overload. Definitely excluded from the warranty is damage resulting from fluid permeation, excessive
dust penetration, intentional damage (on purpose or by gross carelessness), inappropriate
usage (use for purposes for which the device is not suitable), incompetent usage (e.g. not
following the instructions given in the manual), inexpert assembly, lightning strike,
erroneus net voltage. This list is not exhaustive. Acceptance of claims under warranty can never lead to the prolongation of the warranty
period nor commencement of a new warranty period in case of a device replacement. Devices or parts which are replaced under the warranty therefore remain the property of
Varo NV. We reserve the right to reject a claim whenever the purchase cannot be verified or when it
is clear that the product has not been properly maintained. (Clean ventilation slots, carbon
brushes serviced regularly, etc.).
Your purchase receipt must be kept as proof of date of purchase. Your appliance must be returned undismantled to your dealer in an acceptably clean state,
(in its original blow-moulded case if applicable to the unit), accompanied by proof of
purchase.
18 ENVIRONMENT
Should your appliance need replacement after extended use, do not discard it with the household rubbish but dispose of it in an environmentally safe way. Waste produced by electrical machine items should not be handled like normal household rubbish. Please recycle where recycle facilities exist. Check with your Local Authority or retailer for recycling advice.
Copyright © 2022 VARO NV
P a g e | 7 www.varo.com
Page 8
POWXG9540 EN
19 DECLARATION OF CONFORMITY
VARO N.V. - Vic. Van Rompuy N.V Joseph Van Instraat 9 - BE2500 Lier - BELGIUM,
declares that,
Product: Multi-stage submersible pump 750W
Trade mark: POWERplus
Model: POWXG9540
is in conformity with the essential requirements and other relevant provisions of the applicable European Directives, based on the application of European harmonized standards. Any unauthorized modification of the apparatus voids this declaration.
European Directives (including, if applicable, their amendments up to the date of signature);
2011/65/EU
2014/35/EU
2014/30/EU
European harmonized standards (including, if applicable, their amendments up to the date of signature);
EN60335-1 : 2012
EN60335-2-41: 2003
EN75014-1 : 2017
EN75014-2 : 2015
EN IEC61000-3-2 : 2019
EN61000-3-3 : 2013
Keeper of the Technical Documentation : Philippe Vankerkhove, VARO – Vic. Van Rompuy N.V.
The undersigned acts on behalf of the company CEO,
Ludo Mertens Regulatory Affairs – Compliance Manager 20/09/2022, Lier - Belgium
Copyright © 2022 VARO NV
P a g e | 8 www.varo.com
Loading...