Powerplus POWXG9451 User Manual

POWXG9451 EN
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 SYMBOLS ........................................................................................ 2
5 SPECIFIC SAFETY WARNINGS ..................................................... 3
6 ASSEMBLY ...................................................................................... 3
6.1 Electrical connection .............................................................................................. 3
6.2 Earth ........................................................................................................................ 3
7 OPERATION ..................................................................................... 3
7.1 Pressure hose ......................................................................................................... 4
7.2 Safety requirements ................................................................................................ 4
8 CLEANING AND MAINTENANCE ................................................... 5
8.1 Cleaning................................................................................................................... 5
8.2 Cleaning of the built-in filter. .................................................................................. 5
9 TECHNICAL DATA .......................................................................... 5
10 TROUBLE SHOOTING .................................................................... 6
11 WARRANTY ..................................................................................... 7
12 ENVIRONMENT ............................................................................... 7
13 DECLARATION OF CONFORMITY ................................................ 8
Copyright © 2014 VARO NV P a g e | 1 www.varo.com
POWXG9451 EN
Denotes risk of personal injury or damage to the tool.
In accordance with essential safety standards of applicable European directives
This appliance cannot be used by children or people who are physically, mentally or developmentally impaired, or people who lack experience or knowledge, except in case these people receive instruction from a person responsible for their safety, a supervisor, or by studying the preceding
PRESSURE PUMP 800W, WITH TANK POWXG9451
1 APPLICATION
POWXG9451 : these electrical waterpumps/pressure pumps with “press control” and/or pressure tank are only to be used indoors. These are not designed for commercial use.
WARNING! Read this manual and general safety instructions carefully before using the appliance, for your own safety. Your power tool should only be passed on together with these instructions.
2 DESCRIPTION (FIG A)
1. Motor housing
2. Water inlet
3. Water outlet
4. Cable & plug
5. Cable winder
6. Carrying handle
7. Integrated filter
3 PACKAGE CONTENT LIST
Remove all packing materials Remove remaining packaging and transit supports (if existing) Check the completeness of the packing content Check the appliance, the power cord, the power plug and all accessories for transportation
damages.
Keep the packaging materials as far as possible till the end of the warranty period.
Dispose it into your local waste disposal system afterwards.
WARNING Packing materials are no toys! Children must not play with plastic bags! Danger of suffocation!
1 x Water Pump with 1.2m electric cable Manual. Also available in our assortment :
- POWXG94AH : Aspiration hose 8m – 1” with filter and non-return valve
- POWXG94F1 : Filter – 1 Liter
When parts are missing or damaged, please contact your dealer.
4 SYMBOLS
In this manual and/or on the machine the following symbols are used:
Copyright © 2014 VARO NV P a g e | 2 www.varo.com
POWXG9451 EN
instructions concerning use of this appliance. Children should be supervised not to play with the appliance.
5 SPECIFIC SAFETY WARNINGS
This water pump has no water-sprinkling protection feature and should be placed only in a
dry environment. Never place the water pump or operate it in the rain or in a humid space.
This water pump should not be used with flammable or harmful liquids. Idle operation of the water pump must be avoided. This water pump is for work in clean water. The scope of its application includes irrigation
in the garden, water supply to a household, sprinkling in a garden or on farmland.
This water pump may not be exposed for long periods to impurities, sand, stone, sticky
substances, etc., mixed in with the conveyed media. Because the conveyed media may contain chemical corrosive substances, it is necessary to pay special attention to preventing influence by these on the material of the pump body. It is not permitted to use this water pump to convey drinking water.
This appliance cannot be used by children or people who are physically, mentally or developmentally impaired, or people who lack experience or knowledge, except in case these people receive instruction from a person responsible for their safety, a supervisor, or by studying the preceding instructions concerning use of this appliance.
6 ASSEMBLY
During the installation of the water pump, the power supply to the water pump must be
switched off.
During installation of the equipment, it is necessary to keep it under dry and well-ventilated
conditions, at an ambient temperature below 40°C.
If the required pumping water is excessive due to your own action, resulting in flooding of
the irrigation site, a number of protective measures may be taken (e.g. installation of a device for discharging the excess water, an alarm, standby pump, water container, etc.). However, our company is not responsible for any losses thus caused.
Before use, the water pump should be inspected for safety to ensure that there is no
damage to the power cable or the plug.
6.1 Electrical connection
The electrician responsible for installation must check to ensure that the electrical
connection is in accordance with the standard, including the earth terminal.
It is necessary to check the rated current of the electric contact with protective switch - this
must be 30mA.
6.2 Earth
The water pump must be well earthed. Short-circuiting will render the relevant articles of the guarantee invalid. If it is necessary to increase the length of the original cable, a cable with the same section as the original cable must be used.
7 OPERATION
The pumps are not self-priming pumps. This means that the suction hose should first of all be fitted with:
1. Non-return valve with filter; this ensures that, after disconnecting the pump, the hose and the pump do not run dry. This part of the hose is suspended in the water to be pumped away.
2. Hose with coupling nut; this end of the hose is attached to the front of the pump.
3. Both accessories should be securely screwed on to the hose using a hose clip.
Copyright © 2014 VARO NV P a g e | 3 www.varo.com
Loading...
+ 5 hidden pages