
POWXG9417 EN
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 GENERAL POWER TOOL SAFETY WARNINGS .......................... 2
5 BEFORE START-UP, NOTE THE FOLLOWING! ........................... 3
6 INSTALLATION ................................................................................ 3
7 SETTING TO WORK ........................................................................ 4
7.1 Setting the ON/OFF operating point....................................................................... 4
8 CLEANING AND MAINTENANCE ................................................... 4
8.1 Maintenance guidelines .......................................................................................... 4
8.2 Cleaning the impeller .............................................................................................. 5
9 TECHNICAL DATA .......................................................................... 5
10 SERVICE DEPARTMENT ................................................................ 5
11 TROUBLESHOOTING ..................................................................... 6
12 STORAGE ........................................................................................ 6
13 WARRANTY ..................................................................................... 6
14 ENVIRONMENT ............................................................................... 7
15 DECLARATION OF CONFORMITY ................................................ 7
Copyright © 2014 VARO NV P a g e | 1 www.varo.com

POWXG9417 EN
SUBMERSIBLE PUMP 750W WITH SENSOR
POWXG9417
1 APPLICATION
This pump is used primarily as cellar pump. When installed in a shaft, the pump provides
protection from flooding.
It is also used wherever water has to be moved from one place to another, e.g. in the home,
agriculture, horticulture, plumbing and many other applications.
It is not designed for commercial use.
Pollution of the liquid could occur due to leakage of lubricants.
WARNING !For your own safety, read this manual and the general safety
instructions carefully before using the appliance. Your power tool should
only be given to other users together with these instructions.
2 DESCRIPTION (FIG A)
1. Motor housing
2. Water inlet
3. Water outlet
4. Cable & plug
5. Sensor
6. Carrying handle
3 PACKAGE CONTENT LIST
Remove all packaging materials.
Remove remaining packaging and packing inserts (if included).
Check that the package contents are complete.
Check the appliance, the power cord, the power plug and all accessories for
transportation damage.
Keep the packaging materials as far as possible until the end of the warranty period. Then
take it to your local waste disposal system .
WARNING: Packaging materials are not toys! Children must not play with
plastic bags! There is a danger of suffocation!
Submersible pump with 10m electric cable (RNF) with earthed plug
Outlet connection.
Manual
When parts are missing or damaged,
please contact your dealer.
4 GENERAL POWER TOOL SAFETY WARNINGS
Read all safety warnings and instructions. Failure to heed warnings and follow instructions
may result in electric shock, fire and/or serious injury. Keep safety warnings and instructions
for future reference. The term "power tool" in the safety warnings refers to your mainsoperated (corded) power tool or battery-operated (cordless) power tool.
Copyright © 2014 VARO NV P a g e | 2 www.varo.com

POWXG9417 EN
5 BEFORE START-UP, NOTE THE FOLLOWING!
The pump can be connected to any shock-proof plug which has been installed according
to regulations. The plug must have a supply voltage of 230V ~ 5 Hz. Fuse min. 6 Amp.
Caution!
When the pump is to be used near swimming pools or garden ponds and in their area of
protection, it must be equipped with a PRCD (residual current circuit breaker) with a nominal
trip current of max. 30 mA (according to VDE 0100, part 702 and 738).
The pump must not be operated while people are in the swimming pool or in the garden pond!
Please contact your electrician!
Attention!
(Important for your own security) Before starting to run your new submersible pump, please
have the following items checked by an expert:
Ground connection
Zero conductor
Fault current breaker switch must correspond to the safety regulations of the power plants
and they must work faultlessly.
The electrical connections must be protected from moisture.
If there is danger of flooding, the electrical connections must be taken to higher ground.
Circulation of aggressive fluids, as well as the circulation of abrasive materials must be
avoided at all costs.
The submersible motor-driven pump must be protected from frost.
The pump must be protected from running dry.
Access on the part of children should also be prevented with appropriate measures.
Consistency
Your submersible pump is designed for the circulation of water with a maximum temperature
of 35° C. This pump may not be used for other fluids, especially motor fuels, cleaning fluids,
and other chemical products!
6 INSTALLATION
The submersible motor pump is installed as follows:
In a stationary position with fixed pipeline
or
in a stationary position with a flexible hose pipe.
Please note!
You should never install the pump by suspending it unsupported from its delivery pipe or
power cable. The submersible motor pump must be suspended from the specially provided
handle or be placed on the bottom of the shaft. To guarantee that the pump works properly,
the bottom of the shaft must be kept free of sludge and dirt of all kinds.
If the level of water sinks too far, any sludge in the shaft will dry out quickly and stop the pump
from starting up. , Therefore it is necessary to check the submersible motor pump regularly (by
carrying out start-up tests). The “switch on” point can be adjusted by repositioning the sensor
(5) in one of the 4 available positions.
Mains supply
Your new submersible pump is equipped with a shock-proof plug according to regulations. The
pump is designed to be connected to a 230-240V ~50 Hz earthed socket. Make sure that the
socket is sufficiently secured (min. 6 Amp.) and is in excellent condition. Introduce the plug
into the socket and the pump is ready to go.
Copyright © 2014 VARO NV P a g e | 3 www.varo.com