Powerplus POWXG9412 User Manual

POWXG9402 > XG9427 EN
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 GENERAL POWER TOOL SAFETY WARNINGS .......................... 2
5 BEFORE START-UP, NOTE THE FOLLOWING! ........................... 3
6 INSTALLATION ................................................................................ 3
7 SETTING TO WORK ........................................................................ 4
7.1 Setting the ON/OFF operating point....................................................................... 4
8 CLEANING AND MAINTENANCE ................................................... 5
8.1 Maintenance guidelines .......................................................................................... 5
8.2 Cleaning the impeller .............................................................................................. 5
9 TECHNICAL DATA .......................................................................... 6
10 SERVICE DEPARTMENT ................................................................ 7
11 TROUBLESHOOTING ..................................................................... 7
12 STORAGE ........................................................................................ 7
13 WARRANTY ..................................................................................... 7
14 ENVIRONMENT ............................................................................... 8
15 DECLARATION OF CONFORMITY ................................................ 9
Copyright © 2013 VARO NV P a g e | 1 www.varo.com
POWXG9402 > XG9427 EN
SUBMERSIBLE PUMP POWXG9402, -04, -07, -12, -16, -18 & -27
1 APPLICATION
This pump is used primarily as cellar pump. When installed in a shaft, the pump provides protection from flooding. It is also used wherever water has to be moved from one place to another, e.g. in the home, agriculture, horticulture, plumbing and many other applications. It is not designed for commercial use.
WARNING! Read this manual and general safety instructions carefully before using the appliance, for your own safety. Your power tool should only be passed on together with these instructions.
2 DESCRIPTION (FIG A)
1. motor housing
2. water inlet
3. water outlet
4. cable & plug
5. floating switch
6. carrying handle
3 PACKAGE CONTENT LIST
Remove all packing materials Remove remaining packaging and transit supports (if existing) Check the completeness of the packing content Check the appliance, the power cord, the power plug and all accessories for transportation
damages.
Keep the packaging materials as far as possible till the end of the warranty period.
Dispose it into your local waste disposal system afterwards.
WARNING Packing materials are no toys! Children must not play with plastic bags! Danger of suffocation!
Submersible pump with 10m electric cable (RNF) with earthed plug Outlet connection. manual
When parts are missing or damaged, please contact your dealer.
4 GENERAL POWER TOOL SAFETY WARNINGS
Read all safety warnings and all instructions. Failure to follow all warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference. The term "power tool" in the warnings refers to your mains operated (corded) power tool or battery operated (cordless) power tool.
Copyright © 2013 VARO NV P a g e | 2 www.varo.com
POWXG9402 > XG9427 EN
5 BEFORE START-UP, NOTE THE FOLLOWING!
The pump can be connected to any shock-proof plug which has been installed according
to regulations. The plug must have a supply voltage of 230V ~ 50Hz. Fuse min. 6 Amp.
Caution!
When the pump is to be used near swimming pools or garden ponds and in their area of protection, it must be equipped with a PRCD (residual current circuit breaker) with a nominal trip current of max. 30 mA (according to VDE 0100, part 702 and 738). The pump must not be operated while people are in the swimming pool or in the garden pond! Please contact your electrician!
Attention!
(Important for your own security) Before starting to run your new submersible pump, please have the following items checked by an expert:
Ground connection Zero conductor Fault current breaker switch must correspond the safety regulations of the power plants
and they must work faultlessly.
The electrical connections must be protected from moisture. If there is danger of flooding, the electrical connections must be taken to higher ground. Circulation of aggressive fluids, as well as the circulation of abrasive materials must be
avoided at all costs.
The submersible motor-driven pump must be protected from frost. The pump must be protected from running dry. Access on the part of children should also be prevented with appropriate measures.
Consistency
6 INSTALLATION
The submersible motor pumps is installed as follows: In a stationary position with fixed pipeline or in a stationary position with a flexible hose pipe.
Please note!
You should never install the pump by suspending it unsupported from its delivery pipe or power cable. The submersible motor pump must be suspended from the specially provided handle or be placed on the bottom of the shaft. To guarantee that the pump works properly, the bottom of the shaft must be kept free of sludge and dirt of all kinds. If the level of water sinks too far, any sludge in the shaft will dry out quickly and stop the pump from starting up. ,Therefore it is necessary to check the submersible motor pump regularly (by carrying out start-up tests). The floater is adjusted in a way that the pump can immediately be started
Note!
The pump shaft should have minimum dimensions of 40 x 40 x 50 cm, so that the floating switch can move freely.