POWER-ONE QLS25ZD, QLS25ZE, QLS20ZG Datasheet

QLS30 Series – 30A Quarter-Brick DC/DC Converter 48V Input Data Sheet
1.8V, 1.5V, 1.2V Output
REV. 10/1 Page 1 of 8
Applications
Distributed power architectures
Telecommunications equipment
LAN/WAN applications
Features
Cost-effective single board design
Low profile – 11 mm height
Input/output isolation: 1500VDC, basic
insulation
High efficiency
Output back-drive protection
Start-up into high capacitive load
Low conducted and radiated EMI
Output overcurrent protection
Output overvoltage protection
Overtemperature protection
Remote sense
Set point accuracy ± 1%
Remote on/off (primary referenced), positive
or negative logic
Output voltage trim adjust, positive or negative
UL 1950 Recognition, CSA 22.2 No. 950-95 certification, TUV IEC950
Description
The new QLS30 series of single-output DC/DC converters features single board, multi-layer construction and an SMT design that is highly reliable due to the low component count and minimal manufacturing touch time. The QLS30 series uses fewer components than any other equivalently rated single board converter. The converters can deliver a maximum of 30 Amps with a typical efficiency of 85%. The QLS provides superior thermal performance, with minimal derating. The QLS30ZB model converter can deliver 22.8 amperes at 1.8 volt output in ambient conditions of 65°C and 200 LFM. This full featured, low profile converter offers input undervoltage lockout, overload, overvoltage and overtemperature protection. Interface features include remote on/off, remote sense and output voltage trim.
Selection Chart
Model Input
voltage
VDC
Input
current,
max
ADC
Output
voltage
Vout,
VDC
Output rated
current
I
rated,
ADC
Output
Ripple/Noise,
mV p-p
Typical
Efficiency
@ I
rated,
%
QLS30ZB 36-75 1.5 1.8 30 100 86 QLS30ZA 36-75 1.3 1.5 30 100 85 QLS30ZY 36-75 1.1 1.2 30 100 84
This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment
should be followed
.
QLS30 Series – 30A Quarter-Brick DC/DC Converter 48V Input Data Sheet
1.8V, 1.5V, 1.2V Output
REV. 10/1 Page 2 of 8
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect long-term reliability and cause permanent damage to the converter.
Parameter Conditions/Description Min Max Units
Input voltage Continuous
Transient, 100mS
75
100
VDC VDC
Operating Temperature At 100% load -40 100
°C
Storage Temperature -40 125
°C
ON/OFF Control Voltage Referenced to -Vin 50 VDC
Environmental and Mechanical Specifications
All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Shock Halfsine wave, 3 axes 50 g
Sinusoidal Vibration GR-63-Core, Section 5.A.2 1
Weight 1.2/35 Oz/g
Water Washing Standard process Yes
MTBF Per Bellcore TR-NWT-000332 1,980 kHrs
Isolation Specifications
All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Insulation Safety Rating Basic
Isolation Voltage 1500 VDC
Isolation Resistance 10 MOhm
Isolation Capacitance 1800 pF
Input Specifications
All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Input Voltage Continuous 36 48 75 VDC Turn-On Input Voltage Ramping Up 33 VDC Turn-Off Input Voltage Ramping Down 32 VDC
Turn-On Time To Output Regulation Band
100% Resistive Load
510mS
Input Reflected Ripple Current Full Load, 12uH source
inductance
50 mA p-p
Inrush Transient Vin=Vin.max 0.1 A2s
QLS30 Series – 30A Quarter-Brick DC/DC Converter 48V Input Data Sheet
1.8V, 1.5V, 1.2V Output
REV. 10/1 Page 3 of 8
Output Specifications
All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Output Voltage Setpoint Accuracy Vin=Vin.nom, Full Load -1 1 %Vout
Output Current*
See selection chart for I
rated
10 100
%I
rated
Line Regulation
Vin.min to Vin.max, I
rated
0.2 %Vout
Load Regulation Vin=Vin.nom, 10% to
100%I
rated
0.2 %Vout
Total output voltage regulation Over all input voltage, load,
and temperature conditions
-2 2 %Vout
Remote Sense Headroom 0.5 VDC
Dynamic Regulation
Peak Deviation
Settling Time
50-75% load step change
to 1% error band
6
500
%Vout
µS
Admissible Load Capacitance
I
rated
, Nom Vin
20,000
µF
Output Current Limit Threshold** Vout=0.97Vout.nom 110 140
%I
rated
Switching Frequency 300 kHz
Overvoltage Protection,
Non Latching
Over all input voltage and
load conditions
120 140 %Vout
Trim Range
I
rated
, Vin=Vnom
90 110 %Vout
* At Iout<Iout.min, the output may contain low frequency component that exceeds ripple specifications. ** Overcurrent protection is non-latching with auto recovery.
Feature Specifications
All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Shutdown (ON/OFF)
Negative Logic
Converter ON Source Current Converter OFF
Open Circuit Voltage
Positive Logic
Converter ON
Open Circuit Voltage
Converter OFF Source Current
On/Off signal is low – converter is ON
ON/OFF pin is connected to -Vin
ON/OFF pin is floating
On/Off signal is low –converter is OFF
ON/OFF pin is floating
ON/OFF pin is connected to -Vin
-1.0
3.5
3.5
-1.0
2.1
2.5
2.0
1.8
150
5
50
5
1.8 1
VDC
mADC
VDC VDC
VDC VDC VDC
mADC
Overtemperature
Protection
Average Board Temperature 105
°C
Loading...