Power-one HLS30ZD, HLS30ZE, HLS30ZG Datasheet

HLS30 Series – 30A Half-Brick DC/DC Converter 48V Input Data Sheet
5.0V, 3.3V, 2.5V Output
Features
Low profile (-11mm) single board design
1500VDC input to output isolation meets
basic insulation
High efficiency - to 92% at full load
Start-up into high capacitive load
Low conducted and radiated EMI
Output overcurrent protection
Output overvoltage protection
Overtemperature protection
Remote sense
Set point accuracy ± 1%
Remote on/off (primary referenced), positive
Applications
Telecommunications equipment
LAN/WAN applications
Data processing applications
or negative logic
Output voltage trim adjust, positive or negative
UL 1950 Recognized, CSA 22.2 No. 950-95 certified, TUV IEC950
Description
The new HLS30 series of high-density, single-output DC/DC converters, convert standard telecom and datacom voltages into isolated low voltage outputs. High efficiencies and a patent-pending board design create superior thermal transfer that enhances product reliability and eliminates the need for a heatsink.
Selection Chart
Model Input
voltage
VDC
HLS30ZG 36-75 4.8 5.0 30 100 91 HLS30ZE 36-75 3.3 3.3 30 75 89 HLS30ZD 36-75 2.5 2.5 30 50 88
This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment
should be followed
.
Input
current,
max
ADC
Output
voltage
VDC
Output rated
current I
rated
ADC
Output
Ripple/Noise,
mV p-p
Typical Efficiency @ I
rated
%
Rev. 10/01
Page 1 of 8
HLS30 Series – 30A Half-Brick DC/DC Converter 48V Input Data Sheet
5.0V, 3.3V, 2.5V Output
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect long-term reliability and cause permanent damage to the converter.
Parameter Conditions/Description Min Max Units
Input voltage Continuous
Transient, 100mS
Operating Temperature At 100% load -40 100
Storage Temperature -40 125
ON/OFF Control Voltage Referenced to -Vin 50 VDC
75
100
VDC VDC
°C °C
Environmental and Mechanical Specifications
All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Shock Halfsine wave, 3 axes 50 g
Sinusoidal Vibration GR-63-Core, Section 5.A.2 1
Weight 1.6/46 Oz/g
Water Washing Standard process Yes
MTBF Per Bellcore TR-NWT-000332 1,780 kHrs
Isolation Specifications
All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Insulation Safety Rating Basic
Isolation Voltage 1500 VDC
Isolation Resistance 10 MOhm
Isolation Capacitance 1100 pF
Input Specifications
All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Input Voltage Continuous 36 48 75 VDC Turn-On Input Voltage Ramping Up 33 VDC Turn-Off Input Voltage Ramping Down 32 VDC
Turn-On Time To Output Regulation Band
100% Resistive Load
Input Reflected Ripple Current Full Load, 12uH source
inductance
Inrush Transient Vin=Vin.max 0.1 A2s
5mS
80 mA p-p
Rev. 10/01
Page 2 of 8
HLS30 Series – 30A Half-Brick DC/DC Converter 48V Input Data Sheet
5.0V, 3.3V, 2.5V Output
Output Specifications
All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Output Voltage Setpoint Accuracy Vin=Vin.nom, Full Load -1 1 %Vout
Output Current* 3 30 ADC Line Regulation Vin.min to Vin.max, Iout.max 0.2 %Vout
Load Regulation Vin=Vnom, Iout.min to
Iout.max
Total output voltage regulation Over all input voltage, load,
and temperature conditions
Remote Sense Headroom 0.5 VDC
Dynamic Regulation
Peak Deviation
Settling Time
Admissible Load Capacitance Iout.max, Nom Vin 30,000
Output Current Limit Threshold** Vout0.97Vout.nom 110 140 %Iout
Switching Frequency 270 kHz
Overvoltage Protection,
Non Latching
Trim Range Iout.max, Vin=Vnom 90 110 %Vout
50-75% load step change
to 1% error band
Over all input voltage and
load conditions
-2 2 %Vout
120 140 %Vout
0.2 %Vout
8
150
%Vout
µS µF
* At Iout<Iout.min, the output may contain low frequency component that exceeds ripple specifications. ** Overcurrent protection is non-latching with auto recovery.
Feature Specifications
All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Shutdown (ON/OFF)
Negative Logic
- Converter ON
- Source Current
- Converter OFF
-Open Circuit Voltage
Positive Logic
- Converter ON
- Open Circuit Voltage
- Converter OFF
- Source Current Overtemperature
Protection
On/Off signal is low – converter is ON
ON/OFF pin is connected to -Vin
ON/OFF pin is floating
On/Off signal is low –converter is OFF
ON/OFF pin is floating
ON/OFF pin is connected to -Vin
Average PCB Temp. – Shut down
- Recover
-1.0
3.5
3.5
-1.0
0.85 2
3
90
1.8 50
50
1.8
0.46
VDC
mADC
VDC VDC
VDC VDC VDC
mADC
°C
Rev. 10/01
Page 3 of 8
Loading...