Power-one HBT060ZGHH-A Datasheet

HBT Series – Half-Brick DC/DC Converter 48V Input 60 Watt Triple Output
Features
60 Watts maximum total output power
Three fully isolated outputs 5V/12V/12V
5V output provides up to 12 Amps
(2) 12V outputs each provide up to 2.5 Amps
Excellent cross regulation
Low profile – 12.7 mm
High efficiency topology, 88% Typical
Output overcurrent & overvoltage protection
Applications
Distributed power architectures
Computer Equipment
Distributed power architectures
LAN/WAN applications
Data processing applications
Overtemperature protection
Set point accuracy ± 2.0%
1500V Input/output isolation meets basic
insulation requirements
UL 1950 Recognized, CSA 22.2 No. 950-95 certified; TUV IEC950
Data Sheet
Description
The HBT17ZGHH DC-DC Converter operates over an input voltage range of 33Vdc to 75Vdc and provid es three isolated output voltages. The 5V output can provide a full 60W (12 Amperes) of output power and each 12V output can provide up to 30W (2.5 Amperes) of output power. The input is fully isolated from each output and each output is isolated from one another. The isolation of each output provides flexible output configurations and separate output returns, which are important in preventing cross-interference between different loads in system applications. The module has a typical full load efficiency of 88%.
The two-board construction optimizes thermal performance. Power devices are connected to an Integrated Metal Substrate base plate to minimize thermal impedance and a separate control board i s physically isolated from the hotter IMS board. This approach allows for lower average component temperatures on the control board and increases the overall reliability. The comprehensive standard feature set includes remote on/off, and output trim.
Selection Chart
Model Input
voltage
range,
VDC
HBT060ZGHH-A 33-75 3.0 5.0/12.2/12.2 12/2.5/2.5 125/150/150 88
REV. 10/01 Page 1 of 12
Input
current,
max, ADC
www.power-one.com
Output
voltage, VDC
Output
rated
current,
ADC
Output Ripple
and Noise,
mV p-p
Efficiency
%
Data Sheet HBT Series – Half-Brick DC/DC Converter 48V Input 60 Watt Triple Output
Table 1. Absolute Maximum Ratings Parameter Symbol Min Max Units
Input Voltage Continuous Transient Operating Baseplate Temperature Note 1 Storage Temperature Tstg -55 +125
Input to Output Isolation - - 1500 Vdc Output Short Circuit Duration - - Continuous ­Total Output Power Pomax - 60 W No Load Power Dissipation - 6 W
Vi Vi
Tb -40 +100
-
-
80
100
Vdc Vdc
C
°
C
°
Electrical Specifications
Unless otherwise indicated, specifications apply over all input voltages, resistive load, and Tbp=+40°C.
Table 2. Input Specifications Parameter Symbol Min Typ Max Units
Voltage Range Vi 33 48 75 Vdc Maximum Input Current Ii - - 3 A Input Ripple Rejection (120Hz) - 60 - dB Inrush Transient - - 1 A2s Input Reflected Ripple (See Fig.1) 100 MA
Fusing considerations
Caution: This DC-DC converter is not internally fused. An external input fuse must always be used.
p-p
Table 3. Output Specifications Parameter Symbol Min Typ Max Units
Output Power Po1
Po2
Po3 Output Voltage Set Point (Vi=48Vdc, Io1=6A, Io2=Io3=1.25A) Output Line Regulation: (Vi=Vi,min to Vi,max) (Io1=6A, Io2=Io3=1.25A) Output Load Regulation: (0.5A to Iomax) Output Load Regulation: (Vi = Vi.min to Vi,max) (All Loading Conditions) Output Temperature Regulation:
(Tbase =-40 Output Current (Maximum output power limited to 60W)
REV. 10/01 Page 2 of 12
C to +100°C)
°
www.power-one.com
Vo1
Vo2, Vo3
Vo1 - 0.02 0.1 %
Vo1 - 0.2 0.4 %
Vo2, Vo3 10.5 - 13.5 Vdc
All Outputs - 0.02 0.05
Io1 Io2 Io3
-
-
-
4.9
11.834
0.5 0 0
-
-
-
5.0
12.2
6
1.25
1.25
60 30 30
5.1
12.566
12
2.5
2.5
Vdc Vdc
%/
W W W
C
°
A A A
Data Sheet HBT Series – Half-Brick DC/DC Converter 48V Input 60 Watt Triple Output
Parameter Symbol Min Typ Max Units
Output Ripple (See Figure 2) (DC to 20MHz) (Io1 = 6A, Io2,Io3 = 1.25A) Output Current Limit inception (Other outputs at no load)
Transient Response (50% to 100% Load Step,
Io/∆t=0.1A/uSec)
Vo1 Vo2 Vo3
Io1 Io2 Io3
-
-
-
-
-
-
125 150 150
16
6.5
6.5
200 250 250
18
7 7
mVp-p mVp-p mVp-p
A A A
Peak Deviation Settling Time (Vo, 1% of Vo1) Overvoltage Limit Vo1 5.9 - 6.5 Vdc
Vo1 -
-
75 50
200 150
mV
µSec
Table 4. Feature Specifications Parameter Symbol Min Typ Max Units
Remote On/Off, Primary side Vlow Vhigh Sink Current-Logic Low Turn-on time (Within 1% Vonom) - 3.5 5 mSec Switching Frequency - 440 - KHz Output Voltage Adjust (Vo1 only) Vo,adj 8 - 9 %Vo,nom Thermal Shutdown +10 5 +115
Undervoltage Lockout
Turn-on Turn-off
28
-
-
-
-
32 30
-
-
-
1 7 2
32.9
-
V V
mA
C
°
V V
Table 5. Environmental Parameter Min Typ Max Units
Operating Baseplate Temperature -40 - +100 Operating Humidity (non-condensing) 95 %
Storage Humidity (non-condensing) 95 %
C
°
Table 6. Isolation Specifications
Parameter Min Typ Max Units
Input to Each Output 1500 - - Vdc Input to Baseplate 1500 - - Vdc Output to Output 500 - - Vdc Resistance, Input - Output 10 - -
Capacitance, Input - Output - 1000 - pF
REV. 10/01 Page 3 of 12
www.power-one.com
M
Data Sheet HBT Series – Half-Brick DC/DC Converter 48V Input 60 Watt Triple Output
Table 7. EMI & Regulatory Agency Compliance
Conducted Emissions (With input filter configuration in Figure 3.) Safety – Basic UL60950 Recognized, CAN/CSA C22.2 No.
CISPR 22 class A
60950-00 Recognized
Table 8. General Specifications Parameter Min Typ Max Units
Efficiency (Vi=48Vdc, Io1=6A, Io2=Io3=1.25A)
Calculated MTBF (Po=60W, Tbp=40°C)
η
86 87.5 - %
- 900 - kHrs
Table 9. Physical
Parameter Min Typ Max Units
Dimensions 2.30(58.4) 2.40(60.9 ) 0.50(12.70 ) In. (mm) Weight 2.4(68) oz(g) Markings & labeling Includes Part Number, Power-One Logo, Date Code and
Country of Manufacture
REV. 10/01 Page 4 of 12
www.power-one.com
Loading...