1
www.power-one.ch
• Rugged electrical and mechanical design
• Fully isolated outputs
• Operating ambient temperature range
–40...71°C with convection cooling
K Series 150 Watt DC-DC Converters
Input voltage ranges from 8…385 V DC
1or 2 outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
Selection chart
Output 1 Output 2 Type Options
U
o nomIo nom
U
o nomIo nom
Input voltage
[V DC] [A] [V DC] [A] 8...35 V DC
5.1 20 - - AK 1001-7R -9, D, V, P, T, B1
12 10 - - AK 1301-7R -9, D, P, T, B1
15 8 - - AK 1501-7R -9, D, P, T, B1
24 5 - - AK 1601-7R -9, D, P, T, B1
24 5 - - AK 2320-7R -9, D, P, T, B1
30 4 - - AK 2540-7R -9, D, P, T, B1
48 2.5 - - AK 2660-7R -9, D, P, T, B1
12 5 12 5 AK 2320-7R -9, D, P, T, B1
15 4 15 4 AK 2540-7R -9, D, P, T, B1
24 2.5 24 2.5 AK 2660-7R -9, D, P, T, B1
LGA
Output 1 Output 2 Type Type Options
U
o nomIo nom
U
o nomIo nom
Input voltage Input voltage
[V DC] [A] [V DC] [A] 14...70 V DC 20...100 V DC
5.1 25 - - BK 1001-7R FK 1001-7R -9, D, V, P, T, B1
12 12 - - BK 1301-7R FK 1301-7R -9, D, P, T, B1
15 10 - - BK 1501-7R FK 1501-7R -9, D, P, T, B1
24 6 - - BK 1601-7R FK 1601-7R -9, D, P, T, B1
24 6 - - BK 2320-7R FK 2320-7R -9, D, P, T, B1
30 5 - - BK 2540-7R FK 2540-7R -9, D, P, T, B1
48 3 - - BK 2660-7R FK 2660-7R -9, D, P, T, B1
12 6 12 6 BK 2320-7R FK 2320-7R -9, D, P, T, B1
15 5 15 5 BK 2540-7R FK 2540-7R -9, D, P, T, B1
24 3 24 3 BK 2660-7R FK 2660-7R -9, D, P, T, B1